All open City violation records (16)
9 of 16 open City violation records are from the last 24 months (since November 2024), shown newest first. 7 older ones are collapsed below — still open, still counted.
- Open
CN067014 — REPAIR ROOF
NORTH ELEVATION /CANOPY OVER PORCH SYSTEM - ROTTED WOOD WITH HOLES AT MULTIPLE LOCATIONS. (14X-3-303.7)
- Open
CN076024 — REPAIR GUTTER & DOWNSPOUT
ALL ELEVATIONS /GUTTERS AND DOWNSPOUTS - RUSTED AND DETERIORATING THROUGHOUT WITH HOLES; SOME LOOSE WARPED SECTIONS. (14X-3-303.7)
- Open
CN140046 — PIGEONS-NESTING
NORTH, SOUTH AND EAST ELEVATIONS - STOP AND REMOVE EXCESSIVE AMOUNT OF PIGEON FOULING THROUGHOUT. (14X-1-103.2)
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
7405 N /ENTRY VESTIBULE - WATER DAMAGED WALLS AND CEILING THROUGHOUT; MISSING SECTIONS OF DRYWALL WITH EXPOSED WOOD CONSTRUCTION; BLACK-LIKE SUBSTANCE OBSERVED THROUGHOUT VESTIBULE; ACTIVE LEAK WITHIN VESTIBULE AT TIME OF INSPECTION. WATER DAMAGED WALLS AND CEILING WITH BUBBLY, FLAKING PAINT AND BLACK-LIKE SUBSTANCE OBSERVED WITHIN THE FOLLOWING UNITS: 7405 /BASEMENT, 7413 /1, 7413 /3W, 7415 /1E, 7415 /2W, 7415 /311 AND 7423 /BASEMENT. (14X-3-304.3)
- Open
CN197019 — INSTALL SMOKE DETECTORS
7413 N /INTERIOR STAIRWELL - MISSING SMOKE DETECTOR AT UPPERMOST CEILING.7405 - 7425 N /MULTIPLE UNITS THROUGHOUT - MISSING SMOKE DETECTORS. (14X-5-504.8)
- Open
CN031023 — FIRE EXTNGSHR RECHARGE & TAG
7405 - 7425 N /FIRE EXTINGUISHERS - USED EXTINGUISHERS WITH NO TAGS OBSERVED AT INTEIROR STAIRWELL. (14X-5-504.5)
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
BASEMENT HAS BEEN CONVERTED INTO MULTIPLE DWELLING UNITS CONSISTING OF BEDROOMS, KITCHEN AND BATHROOM. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO ITS ORIGINAL STATE. (14A-4-401.1 THRU 14A-4-404.22, 14A-4-410.1, 14A-4-411, 14A-4-411.3 AND TABLE 14A-12-1204.2)
- Open
NC2071 — WORK NOT ALLOWED
REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN THE BASEMENT UNITS WITHOUT A PERMIT. (14A-3-301.1, 14A-4-402.3, 14A-4-413.1 AND 14A-4-413.8.1)
- Open
CN070024 — REPAIR PORCH SYSTEM
NORTH AND SOUTH ELEVATIONS /EXTERIOR 3-STORY WOOD PORCH SYSTEMS - FOUNDATION STATUS UNKNOWN; 6X6 COLUMNS MERELY RESTING ON CONCRETE PAD AND NOT FASTENED TO FOOTINGS; 6X6 COLUMNS OVERSPANNED WITH NO 1/2 LAP SPLICE JOINTS AT MULTIPLE LOCATIONS; 6X6 COLUMN 1/2 LAP JOINTS ARE UNDERSIZED THROUGHOUT AND FASTENED USING ONLY 2 BOLTS AT MULTIPLE LOCATIONS; 6X6 BEAMS NOTCHED INTO 6X6 COLUMNS THROUGHOUT; 2X8 DECK JOISTS OVERSPANNED THROUGHOUT; STRINGERS FASTENED TO COLUMNS USING NAILS ONLY; HAND AND GUARD RAILS FASTENED USING NAILS ONLY; PORCH LANDINGS SEVERELY SLOPED AWAY FROM BUILDING CAUSING POTENTIAL TRIP OR SLIP HAZARDS; HARDWARE RUSTED AND DETERIORATING THROUGHOUT. SUBMIT ARCHITECTURAL PLANS AND OBTAIN BUILDING PERMIT FOR PORCH SYSTEM REPLACEMENTS. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. (14X-3-303.11)
Show 7 older open City violation records (before November 2024)
- Open
CN070014 — REPAIR EXTERIOR STAIR
SEVEN 3 STORY STAIR SYSTEMS ALL LEVELS , DECKING BUCKLING,ROTTING. BEAM TO COLUMN CONNECTIONS NAILED ONLY. 4X4 COLUMNS SUPPORTING STAIRWAYS RESTING ON SLAB,FOUNDATION STATUS UNKNOWN. JOIST CONNECTIONS NAILED ONLY. PLANS AND PERMIT REQUIRED FOR REPAIRS.
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
ALL LEVELS REAR DOORS MISSING SCREENS.
- Open
CN105035 — REPAIR DOOR HARDWARE
ALL LEVELS REAR SCREEN DOORS MISSING CLOSER.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING , NO RESPONSE TO MOST APARTMENTS TO VERIFY DETECTORS.
- Open
CN140046 — PIGEONS-NESTING
7413 3RD FLOOR PIGEON STRAYS, 7409 2ND FLOOR REAR PORCH.
- Open
CN061014 — REPAIR EXTERIOR WALL
PEELING PAINT, WINDOW FRAME 7405-7415 ALL ELEVATIONS
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
BROKEN WINDOW AND DOOR SCREENS, 7411 APARTMENT 2E,1W, 7413 APARTMENT 3W.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Buildings - Plumbing Violation
- building
Building Violation
- building
Building Violation
- other
No Building Permit and Construction Violation
- building
Buildings - Plumbing Violation
- building
Buildings - Plumbing Violation
- building
Buildings - Plumbing Violation
- building
Building Violation
- building
Building Violation
- building
Building Violation
Timeline
- 311 building — Buildings - Plumbing Violation
- 311 building — Building Violation
- 311 building — Building Violation
- 311 other — No Building Permit and Construction Violation
- 311 building — Buildings - Plumbing Violation
- 311 building — Buildings - Plumbing Violation
- 311 building — Buildings - Plumbing Violation
- 311 building — Building Violation
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN140046 PIGEONS-NESTING
- Open City violation record — CN076024 REPAIR GUTTER & DOWNSPOUT
- Open City violation record — CN067014 REPAIR ROOF
- 311 building — Building Violation
- 311 building — Building Violation
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN105035 REPAIR DOOR HARDWARE
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN140046 PIGEONS-NESTING
Recently closed / other violations (sample)
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN070014 REPAIR EXTERIOR STAIR
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN105035 REPAIR DOOR HARDWARE
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN073014 REPAIR EXTERIOR DOOR
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN139016 ABANDONED REFRIGERATOR
Around 7405 N Damen Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:51 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.