Free building report

1960 W FARGO AVE

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 1960 W Fargo Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

33Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (33)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from December 13, 2023. All 33 are collapsed below — still open, still counted.

Show 33 older open City violation records (before November 2024)
  • Open

    PL154027 — SUPPLY HOT WTR MIN TEMP 120DEG

    LOW HOT WATER PRESSURE THROUGHOUT PREMISES.

  • Open

    PL157037 — REPAIR DEFECTIVE FITTINGS

    1964 TIER UNIT PLUMBING WALL DAMAGE TO PLUMBING SYSTEM FROM FIRE THAT OCCURRED IN GARDEN UNIT.

  • Open

    PL232010 — SUBMIT PLANS FOR PLUMBING PRMT

    SUBMIT PLANS TO BUILDING, WATER AND SEWER DEPARTMENTS FOR APPROVAL AND PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM. SPECIFICALLY 1964 TIER LAUNDRY PLUMBING SYSTEM HAS BEEN ADDED WITHOUT PLANS PERMITS OR INSPECTIONS.

  • Open

    PL239010 — ENGAG LIC & BOND PLMBNG CNTRC

  • Open

    PL232011 — OBTAIN PERMIT FOR PLUMBING

  • Open

    CN061044 — FIRE DAMAGE, SINGED,SOOT

    FAILED TO MAINTAIN STRUCTURES AND EQUIPMENT IN GOOD REPAIR, STRUCTURALLY SOUND, AND IN A SANITARY CONDITION. WHERE ANY UNSAFE CONDITIONS AND HAZARDS ASSOCIATED WITH FIRE EXPOSURE CAUSED DAMAGE, DETERIORATION, DEFORMATION, CORROSION, FRACTURES, OR FAILING CONNECTIONS, OR CAUSE A COMPONENT OR SYSTEM TO BE UNSAFE, BEYOND ITS LIMIT STATE; THE COMPONENT OR SYSTEM, ELECTRICAL, FURNACE, WATER HEATING POWER DISTRIBUTION CIRCUITS, SWITCHES, RECEPTACLES AND FIXTURES MUST BE REPAIRED OR REPLACED TO COMPLY WITH THE CHICAGO BUILDING CODE OR THE CHICAGO BUILDING REHABILITATION CODE AS REQUIRED FOR EXISTING STRUCTURES

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    PROVIDE PLANS AND PERMITS FOR THE FIRE DAMAGED AREA IN BASEMENT. CHARRED JOISTS VISIBLE.

  • Open

    CN019012 — ENCLSE FLOOR OPENINGS W/IHR FR

    FIRE SEPARATION REQUIRED AT ALL PLUMBING CHASE WALLS. DANGEROUS AND HAZARDOUS

  • Open

    EL1801 — DEFECTIVE SERVICE

    OVERHEAD SERVICE CABLES SHOWING DETERIORATION. OVERHEAD SPLICES SHOWING SIGNS OF DETERIORATION. SERVICE RISERS NOT SUFFICIENTLY PROTECTED AT ALLEY. ENSURE SERVICE IN APPROVED CONDITION. DANGEROUS AND HAZARDOUS

  • Open

    EL1884 — SEE INSPECTOR COMMENTS

    PROVIDE ONE LINE DIAGRAM AND LOAD CALCULATION FOR ELECTRICAL SERVICE AND FEEDERS. (14E-2-215.5, 14E-2-220.40)

  • Open

    EL1805 — DEFECTIVE DISTRIBUTION

    METER BANK AND PANELS AT MIDDLE BASEMENT MECHANICAL ROOM DETERIORTED WITH LOOSE COVERS. DANGEROUS AND HAZARDOUS

  • Open

    EL1844 — FIRE & WATER DAMAGE

    WATER AND FIRE DAMAGED ELECTRICAL SYSTEM 1962-64 ENTIRE TIER INCLUDING BASEMENT. DANGEROUS AND HAZARDOUS

  • Open

    EL1825 — SYSTEM III

    NO REQUIRED EMERGENCY LIGHTING SYSTEM AT BUILDING.. DANGEROUS AND HAZARDOUS

  • Open

    EL1819 — DEFECTIVE FIXTURES

    UNCOVERED, DAMAGED LIGHT FIXTURES VARIOUS AREAS THROUGHOUT BUILDING. REPLACE REPAIR WHERE REQUIRED.

  • Open

    EL1818 — DEFECTIVE OUTLETS

    DAMAGED CORRODED SWITCHES AND RECEPTACLES VARIOUS AREAS THROUGHOUT BUILDING. REPLACE WHERE REQUIRED.

  • Open

    EL1816 — ADD RECEPTACLES

    INSUFFICIENT RECEPTACLE OUTLETS VISIBLE KITCHEN COUNTER AND WALL SPACES THROUGHOUT PREMISES. ADD WHERE REQUIRED. DANGEROUS AND HAZARDOUS

  • Open

    EL1811 — ADD BRANCH CIRCUITS

    APPEARS TO BE INSUFFIEICNT CIRCUITS SUPPLYING APARTMENTS. ADD CIRCUITS TO PREVENT OVERLOAD. DANGEROUS AND HAZARDOUS

  • Open

    EL1866 — UNAPPROVED CORDS

    EXCESSIVE EXTENSION CORDS VARIOUS AREAS THROUGHOUT APARTMENTS. REMOVE WHERE REQUIRED. DANGEROUS AND HAZARDOUS

  • Open

    EL1875 — INSTALL GFCI'S

    INSTALL GFCI PROTECTION KITCHENS, BATHS, BASEMENT, LAUNDRY, EXTERIOR WHERE REQUIRED THROUGHOUT PREMISES.

  • Open

    EL1834 — LISTED FOR USE TEMP & LOCATION

    EXTERIOR LIGHT FIXUTRES, BOXES, FITTINGS, RACEWAYS MUST BE SUITABLE FOR WET LOCATIONS.

  • Open

    EL1820 — SUPPORT FIXTURES

    UNSUPPORTED, LOOSE LIGHT FIXTURES VARIOUS AREAS EXTERIOR AND THROUGHOUT PREMISES. SUPPORT IN APPROVED MANNER WHERE REQUIRED. DANGEROUS AND HAZARDOUS

  • Open

    EL1880 — DETERIORATED CONDUCTORS

    DETERIORATED, DAMAGED WIRING VISIBLE VARIOUS OPEN BOXES BASEMENT AREA. REPLACE WHERE REQUIRED THROUGHOUT PREMISES. DANGEROUS AND HAZARDOUS

  • Open

    EL1824 — INSTALL ILLUMINATION

    INSUFFIENT OPERABLE ILLUMINATION AT INTERIOR STAIRS, EXTERIOR ENTRIES, EXTERIOR STAIRS, BASEMENT. DANGEROUS AND HAZARDOUS

  • Open

    EL1839 — CORRODED CONDUIT & EQUIP

    CORRODED CONDUIT AND EQUIPMENT VISIBLE AT BASEMENT AND EXTERIOR. REPLACE WHERE REQUIRED.

  • Open

    EL1829 — EXPOSED WIRING

    OPEN WIRING REAR EXTERIOR AND BASEMENT. REMOVE WHERE REQUIRED. DANGEROUS AND HAZARDOUS

  • Open

    EL1806 — PROPER SIZE GRD ELECTRODE COND

    NO VISIBLE WATER GROUND. ENSURE SERVICE GROUNDED IN APPROVED MANNER. DANGEROUS AND HAZARDOUS

  • Open

    EL1885 — Violation

    PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SERVICE EQUIPMENT. (!4A-5-505.2)

  • Open

    CN073044 — REPAIR EXTERIOR DOOR HARDWARE

    SOUTH ENTRY DOORS NOT LATCHING OR LOCKING PROPERLY. DANGEROUS AND HAZARDOUS

  • Open

    EL1886 — Violation

    OBTAIN PERMIT TO CORRECT VIOLATIONS. (14A-4-404.6)

  • Open

    CN197079 — REPAIR/REPLACE SMOKE DETECTORS

    SMOKE DETECTORS BEEPING AND OR INOPERABLE IN 1964 UNIT 1, 1964 TOP OF COMMON STAIR, 1962 UNIT 3, BASEMENT AREA AND OTHER TYPICAL UNITS. DANGEROUS AND HAZARDOUS

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    MISSING CARBON MONOXIDE DETECTORS IN BASEMENT, 1962 UNIT 3 AND OTHER TYPICAL UNITS. DANGEROUS AND HAZARDOUS

  • Open

    CN032013 — FLAMMABLE LIQUIDS 10-GAL LIMIT

    REMOVE GAS CANS WITH GAS FROM BASEMENT STORAGE CLOSET. DANGROUS AND HAZARDOUS

  • Open

    CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU

    MISSING SECTIONS OF DRYWALL/ PLASTER IN BASEMENT CEILING. 1 HR FIRE SEPARATION IS REQUIRED. DANGEROUS AND HAZARDOUS

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — PL232011 OBTAIN PERMIT FOR PLUMBING
  2. Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
  3. Open City violation record — PL232010 SUBMIT PLANS FOR PLUMBING PRMT
  4. Open City violation record — PL157037 REPAIR DEFECTIVE FITTINGS
  5. Open City violation record — PL154027 SUPPLY HOT WTR MIN TEMP 120DEG
  6. Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
  7. Open City violation record — CN032013 FLAMMABLE LIQUIDS 10-GAL LIMIT
  8. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  9. Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
  10. Open City violation record — EL1886
  11. Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
  12. Open City violation record — EL1885
  13. Open City violation record — EL1806 PROPER SIZE GRD ELECTRODE COND
  14. Open City violation record — EL1829 EXPOSED WIRING
  15. Open City violation record — EL1839 CORRODED CONDUIT & EQUIP
  16. Open City violation record — EL1824 INSTALL ILLUMINATION
  17. Open City violation record — EL1880 DETERIORATED CONDUCTORS
  18. Open City violation record — EL1820 SUPPORT FIXTURES
  19. Open City violation record — EL1834 LISTED FOR USE TEMP & LOCATION
  20. Open City violation record — EL1875 INSTALL GFCI'S
  21. Open City violation record — EL1866 UNAPPROVED CORDS
  22. Open City violation record — EL1811 ADD BRANCH CIRCUITS
  23. Open City violation record — EL1816 ADD RECEPTACLES
  24. Open City violation record — EL1818 DEFECTIVE OUTLETS
  25. Open City violation record — EL1819 DEFECTIVE FIXTURES
  26. Open City violation record — EL1825 SYSTEM III
  27. Open City violation record — EL1844 FIRE & WATER DAMAGE
  28. Open City violation record — EL1805 DEFECTIVE DISTRIBUTION
  29. Open City violation record — EL1884 SEE INSPECTOR COMMENTS
  30. Open City violation record — EL1801 DEFECTIVE SERVICE
  31. Open City violation record — CN019012 ENCLSE FLOOR OPENINGS W/IHR FR
  32. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  33. Open City violation record — CN061044 FIRE DAMAGE, SINGED,SOOT

Recently closed / other violations (sample)

No recent closed violations in the sample.

Around 1960 W Fargo Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:01 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com