4110 N Broadway
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 4110 N Broadway, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (13)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from July 7, 2016. All 13 are collapsed below — still open, still counted.
Show 13 older open City violation records (before November 2024)
- Open
CN061014 — REPAIR EXTERIOR WALL
SOUTH ELEVATION / EXTERIOR WALL / MULTIPLE LOCATIONS / MASONRY ABOVE BASEMENT WINDOWS - SEVERELY BULGING AND SHIFTING. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.DANGEROUS AND HAZARDOUS CONDITIONS.SOUTH AND EAST ELEVATIONS / MULTIPLE LOCATIONS / EXTERIOR WALL MASONRY - SHIFTING AND SEVERELY CRACKING. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.DANGEROUS AND HAZARDOUS CONDITIONS.SOUTH ELEVATION / GRADE TO 3RD FLOOR / MASONRY COLUMNS SUPPORTING BALCONIES - BULGING AND SHIFTING MASONRY; WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.
- Open
CN065014 — REPAIR LINTELS
SOUTH ELEVATION / ALL BASEMENT WINDOWS / METAL LINTELS - SEVERELY RUSTED AND BENT. PERMIT ONLY REQUIRED FOR METAL LINTELS REPLACEMENT.
- Open
CN062034 — REPAIR COPING
ALL ELEVATIONS / METAL COPING - SEVERELY RUSTED WITH HOLES.
- Open
CN062034 — REPAIR COPING
SOUTH AND EAST ELEVATIONS /METAL COPING - RUSTED WITH SECTIONS MISSING.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCHES LANDING BEAMS NOT BOLTED TO COLUMNS INSUFFICIENT STRINGER ANCHORS. JOIST HANGERS MISSING FASTENERS. OVER NOTCHED COLUMNS. INSUFFICIENT COLUMN TO PORCH ROOF CONNECTIONS & BOLTS COLUMN SPLICE AT ROOF. MANY LEDGER BOLTS NOT SECURE, SOME LEDGER BOLTS MISSING OPEN MASONRY POCKETS. INSUFFICIENT GAGE ANGLE IRONS FOR BEAM/COLUMN CONNECTION. MANY RAILING CONNECTION TO POSTS/ COLUMNS ONLY SECURED THRU-SPINDLE, INSUFFICIENT RAILING ANCHOR. CENTER PORCH WITH OVER NOTCHED COLUMNS & UNDERSIZED LANDING BEAMS. OBTAIN COMPLETE PLANS & PERMITS.
- Open
CN061014 — REPAIR EXTERIOR WALL
SOUTH ELEVATION FRACTURES STEP FRACTURES, LOOSE MORTAR-AT LINTELS, ABOVE 3RD FLOOR WINDOWS AT CONCRETE SKIM COAT REPAIR, OPEN BALCONY MASONRY POCKETS. LIME STONE CAP STONE FOR BALCONIES WITH FRACTURES & OPEN MORTAR JOINTS.
- Open
CN066034 — REPAIR BALCONY
FRONT BALCONIES WITH INSUFFICIENT NUMBER & SPACING OF LEDGER BOLTS. INSUFFICIENT ANCHORING OF 3RD FLOOR BEAMS TO MASONRY COLUMNS.
- Open
CN197019 — INSTALL SMOKE DETECTORS
SMOKE DETECTOR AT 3 IN 900 NOT WORKING.
- Open
CN102015 — INT WALL/CEILING PEELING PAINT
900 AND 908 AT TOP OF STAIRWELLS WATER DAMAGE AND FLAKING PAINT.
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
900 INTERIOR STAIRS LOOSE TREADS FROM 1 TO 2.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED 2004-06.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR NORTH WEST PORCH MISSING JOIST HANGERS FOR DECK AT 1, LEDGER NOT BOLTED, MISSING JOIST HANGERS AT LANDINGS, STRINGERS NOT BOLTED OR BRACKETED TO STRUCTURE, BEAM/ COLUMN CONNECTIONS NO STRAPS, IMPROPER RAILING HEIGHT AND DESIGN, MISSING MEMBERS, LOOSE RAILS, 6X6 COLUMN FLOATING AT TOP- NO CONNECTION TO PORCH ROOF BEAMS OR JOISTS. TREADS FROM GROUND TO 1 CUPPING AND WARPING. REAR CENTER PORCH JOISTS UNDERSIZED FOR SPAN AND NOT 16" ON CENTERS, IMPROPER RAILING HEIGHTS AND DESIGN, LOOSE AND MISSING MEMBERS, STRINGERS NOT BOLTED TO MASONRY, NOT BOLTED OR BRACKETED TO WOOD STRUCTURE EITHER. LEDGERS NOT BOLTED TO MASONRY, NO STRAPS FOR BEAM TO COLUMN CONNECTIONS. NORTH EAST PORCH IMPROPER GUARD AND HAND RAILS,STRINGERS NOT BOLTED TO MASONRY OR WOOD MEMBERS.
- Open
CN061014 — REPAIR EXTERIOR WALL
EAST ELEVATION SOUTH OF ENTRY STEP FRACTURES IN MASONRY. FRONT BALCONIES AND REAR PORCHES OPEN MASONRY POCKETS.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
Timeline
- 311 building — Building Violation
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
Recently closed / other violations (sample)
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN105035 REPAIR DOOR HARDWARE
- Closed / other
CN197087 CARB MONOX DETECT IN RESID
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN062034 REPAIR COPING
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN106015 REPAIR INTERIOR STAIR SYSTEM
- Closed / other
CN105035 REPAIR DOOR HARDWARE
- Closed / other
CN197087 CARB MONOX DETECT IN RESID
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN106015 REPAIR INTERIOR STAIR SYSTEM
- Closed / other
CN062024 PARAPET
- Closed / other
CN070014 REPAIR EXTERIOR STAIR
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN131026 REPAIR SCREENS
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN062024 PARAPET
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN131026 REPAIR SCREENS
Around 4110 N Broadway
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:42 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.