Free building report

4107 N Broadway

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 4107 N Broadway, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

14Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
2311 building (24 mo)

What rat complaints mean →

All open City violation records (14)

6 of 14 open City violation records are from the last 24 months (since November 2024), shown newest first. 8 older ones are collapsed below — still open, still counted.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    4107, 4109, 4113, 4115 AT FRONT STAIRWAYS / CEILINGS AND WALLS - WATER DAMAGED AT VARIOUS LOCATIONS. PER BUILDING CODE SECTION 14X-3-304.3

  • Open

    CN194039 — REMOVE

    4107 UNIT 1W AT BATHROOM / CEILING AND WALLS - BLACK LIKE SUBSTANCE GROWTH.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    ARRANGE FOR REINSPECTION. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR OF BUILDING INCLUDING UNITS AND ROOF. PER BUILDING CODE SECTION 14A-1-104.7

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    ARRANGE PREMISE INSPECTION, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS, UNABLE TO INSPECT INTERIOR STAIRWAYS AND PORCHES, UNABLE TO VERIFIED CONCERN REGARDING NO SMOKE DETECTORS IN UNIT 3 WEST.

  • Open

    CN067024 — REPAIR EAVES

    FRONT OF THE BUILDING / EAVES - ROTTING SECTIONS. 14X-3-303.7

  • Open

    CN104055 — REPUTTY WINDOW PANES

    ALL ELEVATIONS / WINDOW FRAME - PEELING PAINT. 14X-3-303.1

Show 8 older open City violation records (before November 2024)
  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    ARRANGE PREMISE INSPECTION / MOST UNITS UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY INTERIOR. UNABLE TO VERIFY DETECTORS AND CONDITIONS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY TO MOST DWELLING UNITS. UNVERIFIED DETECTORS AND CONDITIONS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    BUILDING INTERIOR - MOST APARTMENTS , FRONT STAIRWAYS , LAUNDRY ROOM AND MECHANICAL ROOMS - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT ALL INTERIOR STAIRWAYS.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    NORTH - 2 - THREE STORY OPEN WOOD PORCHES - COLUMNS ARE TWISTED AND STACKED. LEDGER BEAMS ONLY NAILED TO BUILDING. SOME BEAMS ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO HEADER JOISTS. STRINGERS ONLY NAILED TO HEADER JOISTS , COLUMNS , AND MASONRY. GUARDRAIL SECTIONS - LOOSE AND PULLING AWAY FROM COLUMNS. GUARDRAILS ONLY 40'' HIGH. SOUTH 3 STORY OPEN WOOD PORCHES - COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKNOWN. STACKED COLUMNS. LEDGER BEAMS ONLY NAILED TO BUILDING. BEAMS ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM JOISTS AND HEADER JOISTS. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. LOOSE HAND AND GUARDRAILS WITH LOOSE PICKETS. 3RD LEVEL GUARDRAIL PULLING LOOSE FROM BUILDING - HAZARDOUS. ROTTED , BROKEN , AND SPLIT TREADS. PLANS AND PERMIT REQUIRED FOR BOTH NORTH AND SOUTH PORCH REPAIRS.

  • Open

    CN074024 — PROVIDE GUARD RAIL 42 IN HIGH

    NORTH -2 BASEMENT STAIRWAYS - GRADE TO BASEMENTS AT GRADE AND SOUTH WEST BASEMENT STAIRWAY - GRADE TO BASEMENT AT GRADE - GUARDRAIL SECTIONS - MISSING.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    NORTH BASEMENT STAIRWAYS - GRADE TO BASEMENTS - HANDRAILS - MISSING PICKETS. SOUTHEAST BASEMENT STAIRWAY GRADE TO BASEMENT - HANDRAIL - PICKETS MISSING.

  • Open

    EL0096 — OBTAIN PERMIT BEFORE SIGN WORK

    ONE BUILDING MOUNTED VINYL 12 X 20' READS "ADVERTISE HERE 847-674-6500, 13-20-520 AND 13-20-550

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • building

    Building Violation

  • building

    Building Violation

Timeline

  1. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  2. Open City violation record — CN194039 REMOVE
  3. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  4. 311 building — Building Violation
  5. Open City violation record — CN104055 REPUTTY WINDOW PANES
  6. Open City violation record — CN067024 REPAIR EAVES
  7. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  8. 311 building — Building Violation
  9. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  10. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  11. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  12. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  13. Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
  14. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  15. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  16. Open City violation record — EL0096 OBTAIN PERMIT BEFORE SIGN WORK

Recently closed / other violations (sample)

  • Closed / other

    CN140016 DWELLING CLEAN AND SANITARY

  • Closed / other

    CN102015 INT WALL/CEILING PEELING PAINT

  • Closed / other

    CN101015 REPAIR INTERIOR WALLS/CEILING

  • Closed / other

    CN134016 RATS

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    CN074024 PROVIDE GUARD RAIL 42 IN HIGH

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN138056 DEBRIS, EXCESSIVE

  • Closed / other

    CN062024 PARAPET

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN068014 REPAIR ROOF STRUCTURE

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN104015 REPLCE WINDOW PANES, PLEXGLAS

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    PL166017 PRV ADT BTHRM VENTIL TO OUTSDE

  • Closed / other

    CN138106 STOP/REMOVE NUISANCE

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

Around 4107 N Broadway

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:42 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.