Free building report
920 W Belle Plaine Ave
Winter habitability score Open City violation records are on file — read the list, not just the score
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 920 W Belle Plaine Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (6)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from May 15, 2009. All 6 are collapsed below — still open, still counted.
Show 6 older open City violation records (before November 2024)
- Open
CN061014 — REPAIR EXTERIOR WALL
EAST ELEVATION LIMESTONE WITH OPEN MORTAR JOINTS, ERODING MORTAR, INCLUDING LIMESTONE FOR FRONT PORCH. ABOVE FRONT PORCH LINTELS VIEWED FORM UNDER FRONT PORCH ROOF OPEN MORTAR JO0INTS, FRACTURES, SHIFTING BRICK. ERODING MORTAR EAST ELEVATION.
- Open
CN062024 — PARAPET
EAST PARAPET AT WEST END, EAST END AND CENTER WITH LOOSE WOOD. EAST, WEST AND NORTH ELVATIONS WITH ERODING MORTAR AND SPALLING BRICK. EAST ELEVATION PARAPET WALL OUT OF PLUMB AND CURVING OVER BUILDING. OBTAIN PERMIT.
- Open
CN069014 — REPAIR DEFECTIVE FOUNDATION
BASEMENT REAR RETAINING WALL WITH FRACTURES, OPEN MORTAR JOINTS, INSUFFICIENT FOR PORCH COULMN FOUNDATION.
- Open
CN070034 — REPLACE D&H PORCH
REAR PORCH DANGEROUS AND HAZARDOUS. SEVERE ROTT FOR COLUMNS AND BEAMS. LOOK OUT BEAMS INSUFFICIENT FOR 7' SPAN. UNDERSIZED STRINGER HEADERS. INSUFFICIENT TREAD DEPTH. ROTTING AND LOOSE RAILS. RAILS ONLY 36" IN HEIGHT. ROTTING DECKING. ROTTING PORCH ROOF DECKING. ROTTING JOISTS FOR DECKS, LANDINGS AND ROOF. COULUMNS WITHOUT SUFFICIENT FOOTINGS. CEMENT POURED AROUND COLUMNS. LANDING WITH UNDERSIZED BEAMS. 4X4 LANDING BEAMS. 4X4 COLUMNS AT DECKS FLANKING STAIRS FROM GROUND EXTENDING TO ROOF UNDER SIZED. INSUFFICIENT ANCHORS OF BEAMS ASND COLUMNS CONNECTIONS, RAILS, AND STRINGERS. OBTAIN COMPLETE PLANS AND PERMIT.
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
REAR AND EAST SERVICE WALKS FRACTURED AND BUCKLED. UNEVEN SURFACES.
- Open
CN075014 — GRADE AND DRAIN LOT
REAR LOT WITH STANDING WATER. ALSO ON EAST SERVICE WALK.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN075014 GRADE AND DRAIN LOT
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN069014 REPAIR DEFECTIVE FOUNDATION
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 920 W Belle Plaine Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 4:04 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.