All open City violation records (30)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from June 11, 2018. All 30 are collapsed below — still open, still counted.
Show 30 older open City violation records (before November 2024)
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
AM EXTENSIVE PARTY ROOM / PENT HOUSE HAS BEEN CONSTRUCTED ON THE ROOF WITHOUT PLANS OR PERMIT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR - (4 TO 6 PORCHES TOTAL) ALL 3 STORY METAL / WOOD PORCHES AT THIS BUILDING ARE TO BE CONSISDERED IN THIS REPORT. *THE COLUMN FOOTINGS ARE OF AN INDETERMINED DEPTH. *THESE ARE PORCHES WITH VERY LARGE, OVERSIZED DECKS. THE MAIN LEDGER BEAMS HAVE UNDERSIZED LEDGER BOLTS THAT ARE NOT SHEAR RESISTANT (5/16") THESE BOLTS ARE SPACED TOO FAR APART (24"-36"). IF THESE PORCHES ARE OVERLOADED A DESTICT COLLAPSE HAZARD WILL EXIST.PLANS AND PERMIT ARE REQUIRED FOR UPGRADES TO ALL OF THE PORCHES AT THIS BUILDING.
- Open
CN062024 — PARAPET
REAR NORTH ELEVATION PARAPET WALL,AT OPEN PORCH, SPALLED BRICKS AND WASHED OUT MORTAR.
- Open
CN074024 — PROVIDE GUARD RAIL 42 IN HIGH
REAR ELEVATION- OPEN STAIRWAY,GRADE TO BASEMENT,MISSING GUARD RAILS.
- Open
CN070014 — REPAIR EXTERIOR STAIR
REAR ELEVATION- TWO EXTERIOR STAIRWAYS,GRADE TO BASEMENT, MISSING HAND RAILS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING- NO OWNER'S ID SIGN POSTED.
- Open
NC2071 — WORK NOT ALLOWED
SOUTHEAST REAR PORCH - ADDITION AT ROOF LEVEL. REMOVE ALL PARTITIONS, STAIRWELLS, FIXTURES (INCLUDING ELECTRICAL AND PLUMBING) INSTALLED AT ROOF ADDITION WITHOUT A PERMIT.
- Open
CN069034 — REPAIR AREAWAY WALL
#930 - RETAINING WALL - SEVERE STRUCTURAL CRACK NEAR ENTRYWAY
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCHES (ALL) - FOUNDATION STATUS UNKNOWN; UNDERSIZED 4X4 COLUMNS; OVERNOTCHED 6X6 COLUMNS; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS, TOENAILED TO BEAMS; LOOSE RAILS AND HANDRAILS THRU-OUT; RAIL HEIGHTS ARE ONLY 37 1/2" - 38";SOUTHEAST REAR PORCH - 2X8 JOISTS SPAN 9'-6 1/2"; 6X6 BEAMS SPAN 11'-7";NORTHEAST REAR PORCH - LOOSE, WEAK, SHAKY STRINGER FROM GRADE TO 1ST FLOOR; STRINGER FROM 2ND TO 3RD FLOOR PITCHED EXCESSIVELY - TRIP/FALL HAZARD; SPINDLES MISSING FROM 1ST TO 2ND FLOOR; 5 3/4" GAP BETWEEN TREAD AND BOTTOM OF SPINDLE;NORTHWEST REAR PORCH - SINGLE 2X8 BEAM SPANS 9'-7" - ALSO SERVING AS RIM JOIST; 7"-15 1/2" GAP BETWEEN TREAD AND BOTTOM OF SPINDLE.PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES.
- Open
CN070034 — REPLACE D&H PORCH
SOUTHWEST REAR PORCH - DANGEROUS AND HAZARDOUS CONDITIONS; SINGLE 2X8 BEAM AT 1ST FLOOR SPLITTING IN HALF - 2ND FLOOR DECK VERY WEAK, SHAKY, AND UNSTABLE (OUTDOOR FURNITURE, WASHER/DRYER UNIT, STORAGE SHED ON 2ND FLOOR DECK IN AREA OF SPLITTING 2X8 BEAM); 2X8 JOISTS SPAN 13'-4". VERY UNSTABLE CONDITION. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
SOUTHEAST REAR PORCH - ADDITION AT ROOF LEVEL; SUBMIT PLANS AND OBTAIN PERMIT FOR ALL WORK RELATED TO AUTHORIZE ROOF ADDITION AT SOUTHEAST REAR PORCH OR RESTORE THE BUILDING TO THE ORIGINAL STATE.
- Open
CN138106 — STOP/REMOVE NUISANCE
EAST, WEST REAR PORCHES - BBQ GRILLS (GAS AND CHARCOAL) ON WOODEN DECKS.
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
EAST, WEST REAR PORCHES - STORAGE SHEDS, FURNITURE, ETC. ON REAR PORCH DECKS OBSTRUCTING PASSAGEWAY.
- Open
CN070024 — REPAIR PORCH SYSTEM
ALL REAR PORCHES WITH SIMILAR DEFICIENCE. MISSING SUFFICIENT LEDGER ANCHORS WHERE JOIST NOT IN MASONARY POCKETS. INSUFFICIENT STRINGER ANCHORS. JOIST HANGERS ON NORTHEAST PORCH MISSING AT LANDINGS. LAPP JOIST WITH INSUFFIECNT ANCHORS. INSUFFICIENT ROOF BEAM TO COLUMN CONNECTIONS. INSUFFIECIENT RAILING ANCHORS UNDERSIZED RAILINGS. SIGNIFICANTLY UNDERSIZED JOIST,2X BEAMS AND 6X6 LOOKOUT BEAMS AT MULTIPLE LOCATIONS. INPROPER STRINGERS CONSTRUCTION FOR LENGTH OF RUN. DEFLECTION DECKS DUE TO UNDERSIZED MATERIAL. OVER NOTCHED COLUMNS. EAST PORCH WITH ANGLE IRONS USED UPSIDE DOWN AS HANGING 6X6 LOOK OUT SUPPORT. OBTAIN COMPLETE PLANS & PERMITS.
- Open
CN062024 — PARAPET
WEST PARAPET- LOOSE MORTAR, FRACTURES, SPALLED BRICK.
- Open
CN061014 — REPAIR EXTERIOR WALL
LOOSE MORTAR AND FRACTURES RESULTING FROM LINTEL CONDITIONS THROUGHOUT. FRACTURES OPEN MORTAR JOINTS RESULTING FROM OPEN SILLS THROUGHOUT.
- Open
CN065034 — REPAIR WINDOW SILLS
OPEN SILL JOINTS, FRACTURES ILLS VARIOUS LOCATIONS THROUGHOUT.
- Open
CN105015 — REPAIR DOOR, INT.
916 INTERIOR ENTRY DOOR NOT CLOSING PROPERLY.
- Open
CN102015 — INT WALL/CEILING PEELING PAINT
WATER DAMAGE TOP 916 STAIRWELL.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCHES WITH UNDERSIZED GUARDRALS, NOT BOLTED TO MASONRY. EAST PORCH WITH ANGLE IRONS USED, UPSIDE DOWN AS HANGING 6X6 LOOKOUT SUPPORT. SOME PORCH REPAIRS DONE WITHOUT REQUIRED PLANS AND PERMIT. PREVIOUS VIOLATIONS ON PORCHES STILL EXIST.
- Open
CN062024 — PARAPET
WEST PARAPET- LOOSE MORTAR, FRACTURES, SPALLED BRICK.
- Open
CN061014 — REPAIR EXTERIOR WALL
LOOSE MORTAR AND FRACTURES RESULTING FROM LINTEL CONDITIONS THROUGHOUT. FRACTURES OPEN MORTAR JOINTS RESULTING FROM OPEN SILLS THROUGHOUT.
- Open
CN065034 — REPAIR WINDOW SILLS
OPEN SILL JOINTS, FRACTURES ILLS VARIOUS LOCATIONS THROUGHOUT.
- Open
CN063014 — CHIMNEY
CHIMNEY SPALLING, FRACTURED BRICK, ERODING MORTAR.
- Open
CN070024 — REPAIR PORCH SYSTEM
SOUTH EAST PORCH WHERE JOISTS NOT IN MASONRY POCKETS LEDGERS NOT BOLTED TO MASONRY. BEAM TO COLUMN CONNECTIONS NEAR STRINGER TO DECK CONNECTIONS INSUFFICIENT- ONLY TOE-NAILED. NORTHEAST PORCH MISSING JOIST HANGERS AT LANDINGS. MISSING BOLTS IN LAPP JOINTS THRU-OUT. INSUFFICIENT ROOF BEAM TO COLUMN CONNECTIONS (ALL PORCHES). STRINGERS NOT BOLTED TO MASONRY. INSUFFICIENT BEAM TO COLUMN CONNECTIONS - UNDER DECK 1- ONLY TOE-NAILED. NORTH WEST PORCH INSUFFICIENT BEAM TO COLUMN CONNECTIONS, MISSING BOLTS AT JOINTS, MISSING JOIST HANGERS, STRINGERS NOT BOLTED TO MASONRY, LOOSE RAILING T GROUND. INSUFFICIENT STRINGER TO OTHER WOOD MEMBER CONNECTIONS (AT TOPS) AT LANDINGS. SOUTHWEST PORCH IMPROPER BEAM TO COLUMN CONNECTIONS, MISSING JOIST HANGERS, JOISTS UNDERSIZED FOR SPAN. OBTAIN PLANS AND PERMITS FOR REPAIRS.
- Open
CN197019 — INSTALL SMOKE DETECTORS
NO SMOKE DETECTOR TOP OF STAIRWELL 916.
- Open
CN061034 — FLAKY INTERIOR PAINT
FLAKING PAINT EAST SIDE CORNICE IN COURTYARD.
- Open
CN070024 — REPAIR PORCH SYSTEM
SOUTH EAST PORCH WHER JOISTS NOT IN MASONRY POCKETS LEDGERS NOT BOLTED TO MASONRY. BEAM TO COLUMN CONNECTIONS NEAR STRINGER TO DECK CONNECTIONS INSUFFICIENT- ONLY TOE-NAILED. NORTHEAST PORCH MISSING JOIST HANGERS AT LANDINGS. MISSING BOLTS IN LAPP JOINTS THRU-OUT. INSUFFICIENT ROOF BEAM TO COLUMN CONNECTIONS (ALL PORCHES). STRINGERS NOT BOLTED TO MASONRY. INSUFFICIENT BEAM TO COLUMN CONNECTIONS - UNDER DECK 1- ONLY TOE-NAILED. NORTH WEST PORCH INSUFFICIENT BEAM TO COLUMN CONNECTIONS, MISSING BOLTS AT JOINTS, MISSING JOIST HANGERS, STRINGERS NOT BOLTED TO MASONRY, LOOSE RAILING T GROUND. INSUFFICIENT STRINGER TO OTHER WOOD MEMBER CONNECTIONS (AT TOPS) AT LANDINGS. SOUTHWEST PORCH IMPROPER BEAM TO COLUMN CONNECTIONS, MISSING JOIST HANGERS, JOISTS UNDERSIZED FOR SPAN. OBTAIN PLANS AND PERMITS FOR REPAIRS.
- Open
CN065014 — REPAIR LINTELS
RUSTING LINTELS THRU-OUT.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN069034 REPAIR AREAWAY WALL
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
- Open City violation record — CN105015 REPAIR DOOR, INT.
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN061034 FLAKY INTERIOR PAINT
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN063014 CHIMNEY
Recently closed / other violations (sample)
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
CN069034 REPAIR AREAWAY WALL
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN070034 REPLACE D&H PORCH
- Closed / other
NC2071 WORK NOT ALLOWED
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
EL0036 COVER OUTLETS AND JBS
- Closed / other
CN062024 PARAPET
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
Around 912 W Gordon Ter
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:00 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.