911 W Addison St

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 911 W Addison St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

58Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (58)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from June 24, 2015. All 58 are collapsed below — still open, still counted.

Show 58 older open City violation records (before November 2024)
  • Open

    PL232010 — SUBMIT PLANS FOR PLUMBING PRMT

    SUBMIT PLANS FOR REVIEW FOR THE BASEMENT, FIRST FLOOR, SECOND FLOOR, AND ATTIC BUILDOUT

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    OBTAIN A PERMIT FOR RENOVATION OF THIS THREE STORY SINGLE FAMILY HOME. AT THE BASEMENT, SEE FINISHED LAUNDRY ROOM, BATHROOM, AND BEDROOM. AT THE FIRST FLOOR, THE KITCHEN AND BATHROOM ARE RENOVATED. AT THE 2ND FLOOR, SEE THE NEW BATHROOM. AT THE 3RD FLOOR, SEE THE NEW BATHROOM AND BEDROOM. WORK INCLUDES BUT IS NOT LIMITED TO TWO NEW GAS-FIRED FORCED WARM AIR FURNACES, A NEW ELECTRICAL SERVICE PANEL, DISTRIBUTION SYSTEM, FIXTURES AND DEVICES, THE NEW KITCHEN SINK, NEW BATHROOM TOILETS, SINKS, BATHTUBS AND SHOWERS. ALSO, THERE IS AN ENCLOSURE OF THE 2ND LEVEL PORCH DECK TO CREATE AN ADDITIONAL LIVING AREA

  • Open

    PL231010 — EXPOSE FOR INSPECT APPROVAL

    EXPOSE ALL SOIL, WASTE, VENT, AND WATER PIPES FOR ROUGH INSPECTION

  • Open

    PL234004 — INSTALL PROPER SIZE TRAP

    INSTALL A TWO INCH TRAP AND WASTE IN THE ATTIC SHOWER

  • Open

    PL237020 — PROPER MATRL WATER SUPPLY PIPE

    THE CONTINUOUS USE WATER HEATER IN THE BASEMENT, REMOVE FLEX WATER LINES TO HEATER, RE-PIPE WITH APPROVED MATERIALS

  • Open

    PL236020 — INSTALL FIXTURES PROPERLY

    FOR THE WATER HEATER, REMOVE THE FLEX GAS CONNECTOR AND HARD-PIPE THE GAS PIPE TO THE UNIT AS PER THE NATIONAL FUEL GAS CODE

  • Open

    PL234004 — INSTALL PROPER SIZE TRAP

    RE-PIPE THE WASTE PIPE FOR THE WASHING MACHINE, INSTALL THE PROPER SIZE TRAP AND VENT

  • Open

    PL234018 — INSTALL VENT PIPE FOR TRAP

    REMOVE THE STUDOR VENT FROM THE FIRST FLOOR KITCHEN SINK AND PROPERLY VENT THE FIXTURE

  • Open

    PL157037 — REPAIR DEFECTIVE FITTINGS

    REMOVE THE RUBBER COUPLINGS AT THE WALL ON BOTH LAVATORIES IN THE FIRST FLOOR AND THE ATTIC AND RE-PIPE WITH PROPER ADAPTERS

  • Open

    PL234004 — INSTALL PROPER SIZE TRAP

    INSTALL A TWO-INCH TRAP AND WASTE IN THE ATTIC SHOWER

  • Open

    PL234018 — INSTALL VENT PIPE FOR TRAP

    REMOVE THE S TRAP FROM THE ATTIC LAVATORY AND PROPERLY VENT THE FIXTURE

  • Open

    PL237020 — PROPER MATRL WATER SUPPLY PIPE

    REMOVE THE FLEX SUPPLIES TO THE TOILET AND LAVATORY IN THE ATTIC, INSTALL COPPER SUPPLIES

  • Open

    PL239010 — ENGAG LIC & BOND PLMBNG CNTRC

    HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT VIOLATIONS

  • Open

    PL171017 — OBTN PERMIT FOR PLUMBING WORK

    PULL A PLUMBING PERMIT TO CORRECT VIOLATIONS

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    OBTAIN A PERMIT FOR RENOVATION OF THIS THREE STORY SINGLE FAMILY HOME. AT THE BASEMENT SEE FINISHED LAUNDRY ROOM, BATHROOM, AND BEDROOM. AT THE 1ST FLOOR, THE KITCHEN AND BATHROOM ARE RENOVATED. AT THE 2ND FLOOR, SEE THE NEW BATHROOM. AT THE 3RD FLOOR, SEE THE NEW BATHROOM AND BEDROOM. WORK INCLUDES BUT IS NOT LIMITED TO TWO NEW GAS-FIRED FORCED WARM AIR FURNACES, A NEW ELECTRICAL SERVICE PANEL, DISTRIBUTION SYSTEM, FIXTURES AND DEVICES, THE NEW KITCHEN SINK, NEW BATHROOM TOILETS, SINKS, BATHTUBS AND SHOWERS. ALSO THERE IS AN ENCLOSURE OF THE 2ND LEVEL PORCH DECK TO CREATE AN ADDITIONAL LIVING AREA

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    THE CONSTRUCTION OF PARTITIONS FORMING WALLS, BEDROOM, AND BATHROOM IN BASEMENT WERE DONE WITHOUT A PERMIT

  • Open

    NC1010 — CONTRARY TO ORIGINAL PLAN

    THE BASEMENT, ORIGINALLY USED FOR STORAGE, IS NOW BEING USED AS A SLEEPING ROOM; THE SECOND FLOOR, ORIGINALLY USED AS BEDROOMS, IS NOW BEING USED AS SLEEPING ROOMS

  • Open

    CN111015 — BASEMENT, DISCONTINUE

    DISCONTINUE USING THE BASEMENT AS A SLEEPING ROOM

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    SUBMIT PLANS AND OBTAIN A PERMIT FOR ALL WORK OR RESTORE THE BASEMENT AND SECOND FLOORS TO THEIR ORIGINAL STATE

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    THE REAR EXTERIOR STAIR SYSTEM AT GRADE TO BASEMENT HAVE MISSING HANDRAIL AND GUARDRAIL SYSTEMS, MISSING TREADS, AND BROKEN CONCRETE

  • Open

    EL0030 — ARMORED CABLE

    REMOVE ALL EXCESSIVE AND DEFECTIVE ARMORED CABLE THROUGHOUT THE BASEMENT AREAS

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    THE REAR PORCH HAS BEAMS PULLING APART AT COLUMNS, THE SUPPORTING COLUMNS ON THE SECOND FLOOR ADDITION ARE ROTTED, THE COLUMNS FACING THE PARKING LOT HAVE MISSING VEHICLE COLLISION PROTECTION; SUBMIT PLANS AND OBTAIN PERMITS FOR REPAIRS OR REPLACEMENT OF THE REAR PORCH

  • Open

    EL0017 — CONTINUITY OF RACEWAY

    PROVIDE GROUND CONTINUITY FOR ALL LIGHTING THROUGHOUT THE BASEMENT AREAS WITH BARE WIRES

  • Open

    EL0020 — SUPPORT FIXTURES

    PROPERLY SUPPORT ALL LIGHTS THROUGHOUT THE BASEMENT AREAS

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    POST OWNERSHIP.

  • Open

    EL0033 — SECURE RACEWAY

    PROPERLY SUPPORT ALL JUNCTION BOXES AND CONDUIT RUNS THROUGHOUT THE BASEMENT AREAS

  • Open

    EL0091 — NO PERMIT WIRING

    FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE BASEMENT, FIRST, AND SECOND FLOOR AREAS WITHOUT PERMITS

  • Open

    PL232010 — SUBMIT PLANS FOR PLUMBING PRMT

    THERE IS NO PERMIT FOR THE PLUMBING REHAB ON THE BASEMENT, FIRST, SECOND, AND THIRD FLOORS

  • Open

    PL234026 — SOIL/WASTE,VENT STK THRU ROOF

    THE REAR OF THE BASEMENT HAS A 2 INCH VENT STACK SPLIT LENGTHWISE, A DANGEROUS AND HAZARDOUS CONDITION

  • Open

    PL237020 — PROPER MATRL WATER SUPPLY PIPE

    THE USE OF FLEXIBLE WATER SUPPLIES TO ALL PLUMBING FIXTURES

  • Open

    PL239010 — ENGAG LIC & BOND PLMBNG CNTRC

  • Open

    EL0023 — INSTALL COVERS

    PROVIDE THE PROPER TYPE COVER FOR OPEN JUNCTION BOXES AND PANEL THROUGHOUT THE BASEMENT AREAS, DANGEROUS AND HAZARDOUS CONDITION

  • Open

    CN077014 — REPAIR FENCE

    FRONT FENCE / RAILS RUSTED AND DAMAGED.

  • Open

    CN063014 — CHIMNEY

    CHIMNEY / WASHED OUT MORTAR.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    SMOKE DETECTOR / FIRST FLOOR APARTMENT.

  • Open

    CN101025 — INT WALL/CEILING CHIP PLASTER

    BASEMENT / CEILING, BROKEN PLASTER.

  • Open

    CN140026 — UNSANITARY CONDITIONS-ANIMALS

    BASEMENT LAUNDRY AREA / DOG URINE AND FECES ON BASEMENT FLOOR.

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    CARBON MONOXIDE DETECTOR / BASEMENT AND FIRST FLOOR APARTMENT.

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    OBTAIN PERMIT - BASEMENT - PARTITION FORMING WALLS, INSTALLATION OF BEDROOM AND BATHROOM IN BASEMENT, NO PERMIT OBTAINED.

  • Open

    NC1010 — CONTRARY TO ORIGINAL PLAN

    BASEMENT ORIGINALLY STORAGE / NOW BEING USED AS A SLEEPING ROOM. SECOND FLOOR ORIGINALLY BEDROOMS, NOW BEING USED AS SLEEPING ROOMS.

  • Open

    CN111015 — BASEMENT, DISCONTINUE

    DISCONTINUE BASEMENT AS A SLEEPING ROOM.

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE TO ORIGINAL STATE. SECOND FLOOR ALTERED TO ACCOMMODATE FOUR SLEEPING ROOMS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    SECOND FLOOR SLEEPING ROOMS - NO INTERIOR INSPECTION. MANAGER NO KEYS TO ROOMS ON SECOND FLOOR OR ATTIC SPACE.

  • Open

    CN194029 — PROVIDE

    SECOND FLOOR - SLEEPING ROOM UNIT DOOR - NO CLOSING DEVICES. 13-196-170.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    REAR EXTERIOR STAIRSYSTEM / GRADE TO BASEMENT - HANDRAIL AND GUARDRAIL SYSTEM MISSING. TREADS HAVE BROKEN CONCRETE.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH / BEAMS PULLING APART AT COLUMN. COLUMNS SUPPORTING SECOND FLOOR ADDITION ROTTED. COLUMNS FACING PARKING LOT - MISSING VEHICLE COLLISION PROTECTION. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS OR REPLACEMENT OF REAR PORCH.

  • Open

    PL160017 — REMV OBSTR FROM DRAINAGE SYSTM

    FIRST FLOOR - KITCHEN SINK PLUGGED, NEED RODDING.

  • Open

    PL232010 — SUBMIT PLANS FOR PLUMBING PRMT

    NO PERMIT FOR PLUMBING REHAB. BASEMENT, FIRST, SECOND AND THIRD FLOORS.

  • Open

    PL234026 — SOIL/WASTE,VENT STK THRU ROOF

    BASEMENT - REAR, 2 INCH BENT STACK SPLIT, LENGTH WISE. DANGEROUS AND HAZARDOUS.

  • Open

    PL237020 — PROPER MATRL WATER SUPPLY PIPE

    USE OF FLEXIBLE WATER SUPPLIES TO ALL PLUMBING FIXTURES.

  • Open

    PL239010 — ENGAG LIC & BOND PLMBNG CNTRC

    HIRE A LICENSED PLUMBING CONTRACTOR.

  • Open

    EL0017 — CONTINUITY OF RACEWAY

    PROVIDE GROUND CONTINUITY FOR ALL LIGHTING THROUGHOUT BASEMENT AREAS WITH BARE WIRES. DANGEROUS AND HAZARDOUS.

  • Open

    EL0020 — SUPPORT FIXTURES

    PROPERLY SUPPORT ALL LIGHTS THROUGHOUT BASEMENT AREAS.

  • Open

    EL0023 — INSTALL COVERS

    PROVIDE PROPER TYPE COVER FOR OPEN JUNCTION BOXES AND PANEL THROUGHOUT BASEMENT AREAS. DANGEROUS AND HAZARDOUS CONDITION.

  • Open

    EL0030 — ARMORED CABLE

    REMOVE ALL EXCESSIVE AND DEFECTIVE ARMORED CABLE THROUGHOUT BASEMENT AREAS.

  • Open

    EL0033 — SECURE RACEWAY

    PROPERLY SUPPORT ALL JUNCTION BOXES AND CONDUIT RUNS THROUGHOUT BASEMENT AREAS.

  • Open

    EL0084 — SEE INSPECTOR COMMENTS

    PROVIDE GFCI PROTECTION FOR ALL BATHROOM, KITCHEN COUNTERTOP AREAS, AND LAUNDRY AREAS. 18-27-210.8, 18-27-570.8..

  • Open

    EL0091 — NO PERMIT WIRING

    OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES, WIRING, DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT BASEMENT, FIRST, SECOND FLOOR AREAS WITHOUT PERMITS.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • other

    No Building Permit and Construction Violation

  • other

    No Building Permit and Construction Violation

Timeline

  1. 311 other — No Building Permit and Construction Violation
  2. 311 other — No Building Permit and Construction Violation
  3. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  4. Open City violation record — PL171017 OBTN PERMIT FOR PLUMBING WORK
  5. Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
  6. Open City violation record — PL237020 PROPER MATRL WATER SUPPLY PIPE
  7. Open City violation record — PL234018 INSTALL VENT PIPE FOR TRAP
  8. Open City violation record — PL234004 INSTALL PROPER SIZE TRAP
  9. Open City violation record — PL157037 REPAIR DEFECTIVE FITTINGS
  10. Open City violation record — PL234018 INSTALL VENT PIPE FOR TRAP
  11. Open City violation record — PL234004 INSTALL PROPER SIZE TRAP
  12. Open City violation record — PL236020 INSTALL FIXTURES PROPERLY
  13. Open City violation record — PL237020 PROPER MATRL WATER SUPPLY PIPE
  14. Open City violation record — PL234004 INSTALL PROPER SIZE TRAP
  15. Open City violation record — PL231010 EXPOSE FOR INSPECT APPROVAL
  16. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  17. Open City violation record — PL232010 SUBMIT PLANS FOR PLUMBING PRMT
  18. Open City violation record — EL0091 NO PERMIT WIRING
  19. Open City violation record — EL0084 SEE INSPECTOR COMMENTS
  20. Open City violation record — EL0033 SECURE RACEWAY
  21. Open City violation record — EL0030 ARMORED CABLE
  22. Open City violation record — EL0023 INSTALL COVERS
  23. Open City violation record — EL0020 SUPPORT FIXTURES
  24. Open City violation record — EL0017 CONTINUITY OF RACEWAY
  25. Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
  26. Open City violation record — PL237020 PROPER MATRL WATER SUPPLY PIPE
  27. Open City violation record — PL234026 SOIL/WASTE,VENT STK THRU ROOF
  28. Open City violation record — PL232010 SUBMIT PLANS FOR PLUMBING PRMT
  29. Open City violation record — PL160017 REMV OBSTR FROM DRAINAGE SYSTM
  30. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  31. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  32. Open City violation record — CN194029 PROVIDE
  33. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  34. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  35. Open City violation record — CN111015 BASEMENT, DISCONTINUE
  36. Open City violation record — NC1010 CONTRARY TO ORIGINAL PLAN
  37. Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
  38. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  39. Open City violation record — CN140026 UNSANITARY CONDITIONS-ANIMALS
  40. Open City violation record — CN101025 INT WALL/CEILING CHIP PLASTER

Recently closed / other violations (sample)

  • Closed / other

    CN138016 SCAVENGER SERVICE

  • Closed / other

    CN066014 REPAIR ORIEL WINDOW

  • Closed / other

    CN138106 STOP/REMOVE NUISANCE

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN104055 REPUTTY WINDOW PANES

  • Closed / other

    CN138016 SCAVENGER SERVICE

  • Closed / other

    CN066014 REPAIR ORIEL WINDOW

  • Closed / other

    CN138106 STOP/REMOVE NUISANCE

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN104055 REPUTTY WINDOW PANES

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN077014 REPAIR FENCE

  • Closed / other

    CN063014 CHIMNEY

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN101025 INT WALL/CEILING CHIP PLASTER

  • Closed / other

    CN140026 UNSANITARY CONDITIONS-ANIMALS

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    EL0084 SEE INSPECTOR COMMENTS

  • Closed / other

    PL160017 REMV OBSTR FROM DRAINAGE SYSTM

Around 911 W Addison St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 10:27 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.