All open City violation records (7)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from October 25, 2016. All 7 are collapsed below — still open, still counted.
Show 7 older open City violation records (before November 2024)
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
MISSING OWNER¿S INFORMATION
- Open
CN061014 — REPAIR EXTERIOR WALL
MAIN ELEVATION SOUTH EAST CORNER PARAPET LOSSE LIME STONES, MORTAR WASH OUT, - PERMIT IS REQUIRED TO REPAIRPARAPET.
- Open
CN070034 — REPLACE D&H PORCH
4X4 AND 6X6 COLUMNS ON SIDE WALK, - RESTING, ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES: FOUNDATION STATUS UNKNOWN, - .- UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, JUST NAIL, - THROUGHOUT ENTIRE PORCH 6X6 COLUMN SPLICE IS LESS THEN 18" IN LENGHT WITH (2) TWO 1/2" BOLTS, - AT ROOF LEVEL 6X6 COLUMN CONNECTED ONLY WITH ONE (1) 2X10, CONNECTIONS IS JUST NAIL, - 2X6 ROOF JOIST SPAN FIFTEEN PLUS OR MINUS BETWEEN SUPPORTS, 2X6 IS UNDERSIZE FOR THAT ROOF SPAN, - GUARD RAILS ARE LESS THEN 42" IN HEIGHT, - GUARD RAILS ARE LESS THEN 36", - 6X6 COLUMNS ARE BOWING AND TWISTING DUE TO POOR BEAM AND COLUMN CONNECTIONS JUST NAIL THROUGHOUT PORCH, - LEDGER BOARD NOT ATTACHED TO MASONRY, - AT 3RD FLOORNORTH EAST 6X6 COLUMN SPLICE IS LESS THEN 18" IN LENGHT AND FASTENED WITH ( TWO 2 1/4" BOLTS VERY DANGEROUS CONDITION ) PLANS AND PERMIT ARE REQUIRED.
- Open
CN197049 — INSTALL EXTRA SMOKE DETECTORS
1ST FL CONDO-SMOKE DETECTOR IS LOCATED GREATER THAN 15 FEET FROM THE FURTHEST BEDROOM.
- Open
CN197019 — INSTALL SMOKE DETECTORS
FRONT STAIRWAY-MISSING SMOKE DETECTOR
- Open
CN190019 — ARRANGE PREMISE INSPECTION
2ND AND 3RD FLOOR CONDOS-NO RESPONSE, UNVERIFIED COMPLAINT OF NON WORKING CARBON MONOXIDE DETECTORS. UNVERIFIED COMPLAINT ON PREVIOUS PORCH VIOLATIONS FROM 10/01/2007
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH COLUMNS AGAINST GARAGE ON SLAB LEDGERS NOT BOLTED STAIRS ONLY 31/2 WIDE OVERNOTCHED COLUMNS AT 2 COLUMN NOTCHED ON SOUTH AND NORTH SIDES WITH LAP JOINT JUST ABOVE AND AND A NOTCH ON WEST SIDE AT SAME LOCATION OVER NOTCHED COLUMNS THRU OUT INSUFFIENCT STRINGER ANCHORS CONNECTIONS INSUFFICIENT BEAM TO COLUMN CONNECTIONS STAIR WIDITH DOWN TO 29 1/2 AT LANDING BEFORE 3 INSUFFICEINT ROTTING ANCHORS UNDERSIZED GUARDRAILS TWISTING COLUMN NORTH EAST CORNER 3 OPEN LAPP JOINT OBTAIN PLANS PERMITS
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN197049 INSTALL EXTRA SMOKE DETECTORS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 842 W Fullerton Ave
- Lincoln Park building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 1:12 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.