Free building report
837 W Windsor Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 837 W Windsor Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (17)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from April 20, 2006. All 17 are collapsed below — still open, still counted.
Show 17 older open City violation records (before November 2024)
- Open
CN073024 — REPAIR EXTERIOR DOOR FRAME
ENTRANCE DOOR FRAME BROKEN APARTMENT 1S X 3N
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
ENTRANCE BALCONY CEILING WOOD STRIPS SEVERELY ROTTED AND FALLING OFF SEE 1ST AND 2ND FLOOR NORTH PORCH APARTMENT IN BEDROOM WALL PEELING PAINTS
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
BASEMENT AND APARTMENT 1N BEDROOM WINDOW PANES BROKEN
- Open
CN197019 — INSTALL SMOKE DETECTORS
APARTMENT 1N MISSING SMOKE DETECTOR
- Open
CN105035 — REPAIR DOOR HARDWARE
APARTMENT 1N INTERIOR ENTRANCE DOOR LOCK BROKEN
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
EAST AND REAR YARD SERVICE WALKWAY BROKEN
- Open
CN070034 — REPLACE D&H PORCH
NORTH FRONT PORCH DANGEROUS AND HAZARDOUS CONDITIONS MOST MEMBERS SEVERELY ROTTED FOUNDATION UNKNOWN ALL SUPPORTING COLUMNS REST ON FLOOR SLABS RETAINING WALLS WITH NO FOUNDATION FOOTING/BASE OR ANY VISIBLE METAL ANCHORS GUARDRAILS 42" HIGH IS LOOSE AND FALLING APART ALL JOISTS MISSING HANGERS LEDGER STRINGERS AND COLUMNS NOT BOLTED 2ND FLOOR DECK BOARD SEVERELY ROTTED 1/4" PLYWOOD BOARD RISERS TO STRENGTHEN THE ROTTED DECK BOARDS TIE NAILS (A) THE JOINTS LOOSEN AND STICKING OUT 2" X4 POST SERVES AS ONE OF THE SUPPORTING COLUMNS SOUTH REAR PORCH ALSO IN DANGEROUS BE HAZARDOUS CONVICTION IT HAS SIMILAR DEFECTS AS IN NORTH PORCH LEDGER BOARD ON THE BASEMENT DECK IS LOOSEN AND DEFLECTING STACKED 2X4 POST USED AS SIDE COLUMN 1ST X 2ND FLOOR GUARDRAILS LOOSE AND DEFLECTING COLUMN BRACING BEAM LOOSE AND DEFLECTING BASEMENT TO GRADE STEPS MISSING HANDRAILS
- Open
CN070014 — REPAIR EXTERIOR STAIR
BASEMENT TO 1ST FLOOR STAIR SYSTEM UNEVEN RISERS AND TREADS 2 X 4 USED AS COLUMN SUPPORT
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
1ST TO 3RD FLOOR INTERIOR STAIR SYSTEM MISSING COLUMN CAP 2ND TO 3RD FLOOR HANDRAIL BROKEN AND GUARDRAIL MISSING
- Open
CN103015 — REPAIR FLOOR
BASEMENT FLOOR BROKEN AND FILLED WITH SHARP SANDS
- Open
NC9012 — III-B AND IV-A FIRE RESISTANCE
BASEMENT FLOOR-1/2" DRY WALLS ERECTED TO FORM FOUR STORAGE ROOMS
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
OBTAIN PERMIT FOR WORK REPAIRS
- Open
CN076034 — REPAIR GUTTER
ROOF GUTTER HOLES SOUTH ELEVATION
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
SUBMIT PLANS PREPARED SIGNED AND SEALED BY A LICENSED ARCHITECT OR REGISTERED STRUCTURAL ENGINEERS FOR APPROVAL AND OBTAIN PERMIT FOR PORCH REPLACEMENT
- Open
CN138056 — DEBRIS, EXCESSIVE
JUNK AND DEBRIS ACCUMULATIONS ON BASEMENT FLOOR 1ST AND 2ND PORCH DECKS
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
BROKEN WINDOW SCREENS NORTH ELEVATIONS 3RD FLOOR
- Open
CN014012 — NO CLOSET/STORAGE UNDER STAIR
BUNDLE WOOD AND GARBAGE ACCUMULATION UNDER REAR PORCH SYSTEM
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
Timeline
- 311 building — Building Violation
- Open City violation record — CN014012 NO CLOSET/STORAGE UNDER STAIR
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
- Open City violation record — CN138056 DEBRIS, EXCESSIVE
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN076034 REPAIR GUTTER
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — NC9012 III-B AND IV-A FIRE RESISTANCE
- Open City violation record — CN103015 REPAIR FLOOR
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — CN105035 REPAIR DOOR HARDWARE
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN073024 REPAIR EXTERIOR DOOR FRAME
Recently closed / other violations (sample)
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN071014 REPAIR EXTERIOR PLATFORM
- Closed / other
CN138106 STOP/REMOVE NUISANCE
- Closed / other
EL0022 EXPOSED WIRING FIXTURES
Around 837 W Windsor Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:22 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.