Free building report

801 W Cornelia Ave

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 801 W Cornelia Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

30Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (30)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from July 31, 2024. All 30 are collapsed below — still open, still counted.

Show 30 older open City violation records (before November 2024)
  • Open

    EL1857 — SMOKE & CARBON DETECTORS

    3448 N HALSTED / SMOKE DETECTOR - MISSING.

  • Open

    CN031013 — FIRE EXTNGSHR REQ, RESDNTL

    3448 N HALSTED / SMOKE SHOP FIRE EXTINGUISHER - MISSING.

  • Open

    CN131026 — REPAIR SCREENS

    ALL ELEVATIONS / SCREENS - MISSING, TORN IN VARIOUS LOCATIONS.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING - NO RESPONSE TO DWELLING UNITS DOOR INTERCOM SYSTEM AT FRONT GATE NOT WORKING, 1ST FLOOR COMMERCIAL UNITS CLOSED AT TIME OF INSPECTION - UNVERIFIED DETECTORS AND CONDITIONS.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING - NO RESPONSE TO DWELLING UNITS DOOR INTERCOM SYSTEM AT FRONT GATE NOT WORKING, ST FLOOR COMMERCIAL UNITS CLOSED AT TIME OF INSPECTION - UNVERIFIED DETECTORS AND CONDITIONS.

  • Open

    CN062024 — PARAPET

    WEST PARAPET WALL - WASHED OUT MORTAR.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. EPP PERMIT # 100352243 ISD -07 / 07 /2010 - NOT FINALIZED. RENOVATION PERMIT # 100249295 ISD 10 / 03 / 2008 - NOT FINALIZED.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING NOT REG. 2005 THRU 2008

  • Open

    CN065014 — REPAIR LINTELS

    EAST ELEVATION ALL FLOORS 3448 THRU 3458 AND FRONT COURTYARD 801 THRU 813 ALL FLOORS NORTH ELEVATION ALL FLOORS EAST ELEVATION ALL-FLOORS THAT HAVE NOT BEEN REPLACED WEST ELEVATION 1-3 FLOORS SOUTH ELEVATION 2ND AND 3RD FLOORS AT TRIPLE WINDOWS RUSTED AND SAGGING LINTEL PERMIT REQUIRED FOR REPLACEMENT AND OR REPAIRS

  • Open

    CN061074 — PROTECT SIDEWALK DURING CONST

    CANOPY REQUIRED OVER PUBLIC WALKWAY DURING REPAIR OF LINTELS

  • Open

    CN074024 — PROVIDE GUARD RAIL 42 IN HIGH

    EAST ELEVATION 801,803 AND 805 REAR STAIRWAYS GUARDRAILS AT 2ND AND 3RD FLOOR MADE OF BRICK ARE TOO LOW NEED TO BE 42" HIGH

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    REAR STAIRS SYSTEMS-801,803,805,811 AND 813-CONDITIONS TYPICAL THRU-OUT ALL (1) 4X4 CENTER POST COLUMN USED FOR SUPPORT OVER 12 FEET HIGH (2) 4X4 COLUMN RESTING ON CONCRETE SLAB (3) FOUNDATION STATUS UNKNOWN (4) 801-4X4 STEEL CENTER POST RESTING ON CONCRETE BLOCK ONTOP OF CONCRETE SLAB (5) 4X4 COLUMNS STACKED WITH BUTT JOINTS TOE NAILED (6) 4X4 COLUMNS WITH LAP JOINTS-HAVE GAPS AND JOINTS ONLY NAILED (7) ROTTED WOOD THRU-OUT ALL (8) LEDGER NOT BOLTED WERE NEEDED (9) 2X8 JOIST SKABBED (10) MISSING JOIST HANGERS (11) SINGLE 2X8 USED AS BEAM (12) STRINGER INADEQUATELY SUPPORTED AND SKABBED CONTINUED ON #2 STAIR TREADS TOO SMALL WITH SOME LOOSE (14) 805 STAIRS LEANING (15) GUARD RAILS TOO LOW (16) DECKING WARPED AND ROTTED (17) PICKETS OVER 4 INCHES APART PLANS AND PERMIT REQUIRED FOR ALL

  • Open

    PL169017 — REMOVE STAGNANT WATER BSMT

    805 REAR STAIRS AT BASEMENT FLOODED

  • Open

    EL0084 — SEE INSPECTOR COMMENTS

  • Open

    RF302021 — PRV RECEIVER

    450# FOR TWO TECUMSEH 1/2 HP REMOTE REFRIGERATION UNITS LOCATED IN BASEMENT SERVING WALK IN COOLERS

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INT. OF BUILDING NO RESPONSE UNVERIFIED DET. CONDITIONS UNABLE TO INSPECT INT. STAIRWAYS.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING NOT REG. 2005 THRU 2008

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCHES- SOUTHWEST PORCH 6X6 COLUMNS RESTING ON CONRETE SLAB. FOUNDATION STATUS UNKNOWN, WOOD DRYROTTED THRU-OUT, LAP JOINT ON COLUMNS TOO SMALL, COLUMNS OVER NOTCHED 2X8 JOIST OVER SPANNED. LEDGER BOARD MISSING BOTS, MISSING JOIST HANGERS, STRINGERS OVERCUT, SKABBED AND INADEQUATELY SUPPORTED AT SUPPORTS, RAILING TOO LOW WITH HORIZONTAL PICKETS. LOOKOUT 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN STRINGER INADEQUATELY SUPPORTED, MISSING JOIST HANGERS RAILING TOO LOW EAST AND WEST PORCHES STRINGERS INADEQUATELY SUPPORTED PLANS AND PERMITS REQUIRED. FOR ALL PORCH REPAIRS AND OR REPLACEMENTS.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCHES- SOUTHWEST PORCH 6X6 COLUMNS RESTING ON CONRETE SLAB. FOUNDATION STATUS UNKNOWN, WOOD DRYROTTED THRU-OUT, LAP JOINT ON COLUMNS TOO SMALL, COLUMNS OVER NOTCHED 2X8 JOIST OVER SPANNED. LEDGER BOARD MISSING BOTS, MISSING JOIST HANGERS, STRINGERS OVERCUT, SKABBED AND INADEQUATELY SUPPORTED AT SUPPORTS, RAILING TOO LOW WITH HORIZONTAL PICKETS. LOOKOUT 6X6 AND 4X4 COLUMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN STRINGER INADEQUATELY SUPPORTED, MISSING JOIST HANGERS RAILING TOO LOW EAST AND WEST PORCHES STRINGERS INADEQUATELY SUPPORTED PLANS AND PERMITS REQUIRED. FOR ALL PORCH REPAIRS AND OR REPLACEMENTS.

  • Open

    CN065014 — REPAIR LINTELS

    ALL ELEV. SEVERLY SAGGING AND RUSTED LINTELS PERMIT REQUIRED

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEV./ UNDER 3RD FLR. WINDOW SILLS WITH WASHED OUT MORTAR.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    SOUTHWEST STAIRS TO BSMT. MISSING HANDRAIL

  • Open

    CN065014 — REPAIR LINTELS

    ALL ELEV. SEVERLY SAGGING AND RUSTED LINTELS PERMIT REQUIRED

  • Open

    CN061074 — PROTECT SIDEWALK DURING CONST

    CANOPY REQUIRED OVER PUBLIC WALKWAY DURING REPAIR OF LINTELS

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    SOUTHWEST STAIRS TO BSMT. MISSING HANDRAIL

  • Open

    CN065034 — REPAIR WINDOW SILLS

    SOUTH ELEV. WINDOW SILLS WITH WASHED OUT MORTAR.

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    PERMIT FOR REPAIRS.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    (807) WORN CENTER 6X6 COLUMN 2TO3 SCABBED BEAMS AND STRINGERS. NO METAL STRAPS ON BEAM/COLUMN CONNECTORS, 809 COLUMN ON SIDE WALK: 1ST FLOOR DECK JOIST ROTTED WORN. 809 1TO2 ROTTED AND SCABBED OUTER STRINGER. 801 2TO3 ROTTED RISERS AND STRINGERS 803 3RD FLOOR JOIST IMPROPERLY NOTCHED INTO WALL.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    REAR 805 SILLS: CRACKED.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    REAR COURTYARD'S 3RD FLOOR UNDER SILL: UP IN JOINTS.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN131026 REPAIR SCREENS
  2. Open City violation record — CN031013 FIRE EXTNGSHR REQ, RESDNTL
  3. Open City violation record — EL1857 SMOKE & CARBON DETECTORS
  4. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  5. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  6. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  7. Open City violation record — CN062024 PARAPET
  8. Open City violation record — PL169017 REMOVE STAGNANT WATER BSMT
  9. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  10. Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
  11. Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
  12. Open City violation record — CN065014 REPAIR LINTELS
  13. Open City violation record — CN198019 FILE BLDG REGISTRATION
  14. Open City violation record — EL0084 SEE INSPECTOR COMMENTS
  15. Open City violation record — RF302021 PRV RECEIVER
  16. Open City violation record — CN065034 REPAIR WINDOW SILLS
  17. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  18. Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
  19. Open City violation record — CN065014 REPAIR LINTELS
  20. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  21. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  22. Open City violation record — CN065014 REPAIR LINTELS
  23. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  24. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  25. Open City violation record — CN198019 FILE BLDG REGISTRATION
  26. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  27. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  28. Open City violation record — CN065034 REPAIR WINDOW SILLS
  29. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  30. Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR

Recently closed / other violations (sample)

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN074024 PROVIDE GUARD RAIL 42 IN HIGH

  • Closed / other

    CN065014 REPAIR LINTELS

  • Closed / other

    CN074024 PROVIDE GUARD RAIL 42 IN HIGH

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    PL169017 REMOVE STAGNANT WATER BSMT

  • Closed / other

    CN065034 REPAIR WINDOW SILLS

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    CN065014 REPAIR LINTELS

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN061074 PROTECT SIDEWALK DURING CONST

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    NC2021 PERMIT REQUIRED - CONTRACTOR

Around 801 W Cornelia Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 2:24 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com