Free building report

7721 N SHERIDAN RD

Winter habitability score Open City violation records are on file — read the list, not just the score

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 7721 N Sheridan Rd, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

3Open City violation records
0Open heat-related City records
1311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (3)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 21, 2014. All 3 are collapsed below — still open, still counted.

Show 3 older open City violation records (before November 2024)
  • Open

    NC2061 — WORK CONTRARY TO PERMIT

    PERMIT #100457950 ISSUED 9/14/2012 FOR REPLACE DRYWALL , WINDOWS ,FLOORING , REPLACE PLUMBING FIXTURES , REPAIR WATER , WASTE LINES AS NEEDED IN UNIT 1S , ELECTRICAL ON SEPARATE PERMIT. ALL WORK SAME AS EXISTING - NO STRUCTURAL . WORK BEYOND SCOPE OF PERMIT . PERMIT NOW REVOKED . PLANS AND PERMITS REQUIRED FOR 7721 #1 SOUTH APARTMENT TO INCLUDE ALL STRUCTURAL AND INTERIOR WALLS ( REMOVED ) , FLOOR JOIST REPAIRED , REPLACED NOT AS EXISTING . ALL VENTILATION ( FURNACE AND DUCTWORK NOW INSTALLED IN BASEMENT OF COMMON AREA OF BUILDING , NOT IN UNIT ) ,ALL PLUMBING AND ELECTRICAL REMOVED AND REQUIRES DRAWINGS . APARTMENT IS NOW GUTTED TO EMPTY BOX WITH ALL MECHANICALS , STRUCTURAL AND LOAD BEARING WALLS AND PARTITION WALLS REMOVED .

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    7721 N. APARTMENT #1S -SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT AND FIRST FLOOR OR RESTORE THE BUILDING TO THE ORIGINAL STATE . PLANS AND PERMITS REQUIRED FOR 7721 #1 SOUTH APARTMENT TO INCLUDE ALL STRUCTURAL AND INTERIOR PARTITION WALLS ( REMOVED ) , FLOOR JOIST REPAIRED , REPLACED NOT AS EXISTING . ALL VENTILATION ( FURNACE AND DUCTWORK NOW INSTALLED IN BASEMENT OF COMMON AREA OF BUILDING , NOT IN UNIT ) , ALL PLUMBING AND ELECTRICAL REMOVED AND REQUIRES DRAWINGS . APARTMENT IS NOW GUTTED TO EMPTY BOX WITH ALL MECHANICALS , STRUCTURAL , LOAD BEARING AND PARTITION WALLS REMOVED .

  • Open

    NC2061 — WORK CONTRARY TO PERMIT

    7721 N. APARTMENT #1S - PERMIT # 100457950 ISSUED 9/14/2012 FOR REPLACE DRYWALL, WINDOWS , FLOORING , REPLACE PLUMBING FIXTURES , REPAIR WATER AND WASTE LINES AS NEEDED , ALL WORK SAME AS EXISTING , NO STRUCTURAL WORK . WORK BEYOND SCOPE OF PERMIT , PERMIT NOW REVOKED . PLANS AND PERMITS REQUIRED .

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • rodent

    Rodent Baiting/Rat Complaint

Timeline

  1. 311 rodent — Rodent Baiting/Rat Complaint
  2. Open City violation record — NC2061 WORK CONTRARY TO PERMIT
  3. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  4. Open City violation record — NC2061 WORK CONTRARY TO PERMIT

Recently closed / other violations (sample)

  • Closed / other

    CN132046 SAFE WORKING CONDITIONS

  • Closed / other

    CN032035 NO GASOLINE(LPG) STORAGE

  • Closed / other

    CN138066 DEMO DEBRIS

  • Closed / other

    EL0016 ADD RECEPTACLES

  • Closed / other

    CN138056 DEBRIS, EXCESSIVE

  • Closed / other

    CN104015 REPLCE WINDOW PANES, PLEXGLAS

  • Closed / other

    CN132046 SAFE WORKING CONDITIONS

  • Closed / other

    CN012012 1/2HR FLR OVER BSMT,3+DU,PRE57

  • Closed / other

    CN132016 HEAT UNIT ADEQUATELY

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN132046 SAFE WORKING CONDITIONS

  • Closed / other

    CN110045 EXT. WALL. FIRE RESISTANCE

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN104035 MAINTAIN WINDOW

  • Closed / other

    CN073024 REPAIR EXTERIOR DOOR FRAME

  • Closed / other

    CN196019 NO POSTED ADDRESS

  • Closed / other

    CN074024 PROVIDE GUARD RAIL 42 IN HIGH

  • Closed / other

    CN043013 1HR ENCL FLR TO FLR SHAFT/DUCT

  • Closed / other

    CN138066 DEMO DEBRIS

  • Closed / other

    CN062024 PARAPET

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN190020 INSPECT CONSTRUCTION WORK

  • Closed / other

    CN137056 STOP STORING GARBAGE

  • Closed / other

    NC2011 PLANS & PERMITS REQ - CONTRCTR

Around 7721 N Sheridan Rd

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:13 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.