Free building report

7655 N GREENVIEW AVE

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 7655 N Greenview Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

12Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (12)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from August 3, 2020. All 12 are collapsed below — still open, still counted.

Show 12 older open City violation records (before November 2024)
  • Open

    CN131026 — REPAIR SCREENS

    ALL ELEVATIONS / MULTIPLE LOCATIONS / WINDOW SCREENS - RIPPED.

  • Open

    CN131016 — SCREEN OUTER DOORS, WINDOWS

    ALL ELEVATION / MULTIPLE LOCATIONS / WINDOW SCREENS - MISSING.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO INTERIOR OF BUILDING TO VERIFY COMPLAINT OF CARBON MONOXIDE DETECTOR LEAK.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION.

  • Open

    CN062034 — REPAIR COPING

    NORTH ELEVATION NEAR ALLEY COPING STONE SHIFTING OUTWARD WITH STEP FRACTURES IN BRICK BELOW.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    NO BUILDING REGISTRATION.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    TWO 3 STORY PORCHES, BEAM TO COLUMN CONNECTIONS NAILED ONLY, 6X6 COLUMNS LAP JOINTS WITH ONLY TWO BOLTS, BEAMS NOTCHED INTO COLUMNS AT LAP JOINTS. ALL RAILING SECTIONS WITH LADDER TYPE PICKETS, ALSO MISSING CENTER SUPPORT POSTS.PLANS AND PERMIT REQUIRED FOR REPAIRS.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    REAR BASEMENT STAIRWAY WITH ONE INCH TUBE GAURD RAIL,UNDER SIZED AND LADDER TYPE.PERMIT REQUIRED FOR REPLACEMENT.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING, NO RESPONSE TO MOST APARTMENTS IN ORDER TO VERIFY DETECTORS.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    REAR BASEMENT STAIRWAY WITH ONE INCH TUBE GAURD RAIL,UNDER SIZED AND LADDER TYPE.PERMIT REQUIRED FOR REPLACEMENT.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING NOT REGISTERED FROM 1990 THRU 2009.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING ENTRY REFUSED, UNVERIFIED DETECTORS,CONDITIONS AND OCCUPANCY.UNABLE TO INSPECT INTERIOR STAIRWAYS REAR YARD - NO ENTRY UNABLE TO INSPECT REAR PORCHES.

  • Open

    CN065014 — REPAIR LINTELS

    NORTH AND WEST ELEVATIONS RUSRED AND SAGGING LINTELS - OERMIT REQUIRED.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
  2. Open City violation record — CN131026 REPAIR SCREENS
  3. Open City violation record — CN062034 REPAIR COPING
  4. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  5. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  6. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  7. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  8. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  9. Open City violation record — CN198019 FILE BLDG REGISTRATION
  10. Open City violation record — CN065014 REPAIR LINTELS
  11. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  12. Open City violation record — CN198019 FILE BLDG REGISTRATION

Recently closed / other violations (sample)

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN065014 REPAIR LINTELS

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

Around 7655 N Greenview Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:41 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address