Free building report
7522 N Hoyne Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 7522 N Hoyne Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (12)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from November 20, 2017. All 12 are collapsed below — still open, still counted.
Show 12 older open City violation records (before November 2024)
- Open
CN197039 — RELOCATE SMOKE DETECTOR
7522 UNIT M AND 3M SMOKE DETECTORS - 2FT BELOW CEILING.
- Open
CN061014 — REPAIR EXTERIOR WALL
WASHED OUT MORTAR.
- Open
CN062024 — PARAPET
NORTH ELEVATION PARAPET - MINOR WASHED OUT MORTAR.WEST ELEVATION PARAPET - SPALLING BRICKS AND WASHED OUT MORTAR.
- Open
CN063024 — CHIMNEY CAPPING
WASHED OUT MORTAR.
- Open
CN065034 — REPAIR WINDOW SILLS
WINDOW SILLS - WASHED OUT MORTAR.NORTH ELEVATION - BASEMENT FRACTURED SILL.7522 APTARTMENT 1N - FRACTURED AND SHIFTED SILL.
- Open
CN067014 — REPAIR ROOF
ROOF ROTTED.
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
STORAGE ON ALL REAR PORCHES BLOCKING EGRESS.
- Open
CN070024 — REPAIR PORCH SYSTEM
1. WOOD ROTTED.2. 4X4 COLUMNS RESTING ON CONCRETE SLAB.3. FOUNDATION STATUS UNKNOWN.4. 4X6 COLUMNS OVER NOTCHED.5. 4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET HIGH.6. 2X8 JOIST OVER SPANNED (FROM 12 TO 15 FEET).7. MISSING JOIST HANGERS.8. STRINGERS INADEQUATELY SUPPORTED.9. STAIR TREADS TOO SMALL.10. LAP JOINTS ON COLUMNS ONLY NAILED TOGETHER.11. GUARDRAILS TOO LOW.12. PLANS AND PERMIT REQUIRED.
- Open
CN073014 — REPAIR EXTERIOR DOOR
MISSING GLASS PANE IN REAR DOOR.
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
1ST FLOOR - BROKEN GLASS PANE.NORTH ELEVATION - BASEMENT WINDOW MISSING GLASS PANE.
- Open
CN198019 — FILE BLDG REGISTRATION
NOT REGISTERED FROM 2007 THRU 2009.
- Open
CN070014 — REPAIR EXTERIOR STAIR
MISSING HANDRAILS.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN073014 REPAIR EXTERIOR DOOR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN067014 REPAIR ROOF
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN063024 CHIMNEY CAPPING
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 7522 N Hoyne Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 1:28 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.