Free building report
7381 N DAMEN AVE
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 7381 N Damen Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (34)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 9, 2024. All 34 are collapsed below — still open, still counted.
Show 34 older open City violation records (before November 2024)
- Open
CN131026 — REPAIR SCREENS
FRONT ELEVATION /WINDOW SCREENS - RIPPED.
- Open
CN077014 — REPAIR FENCE
REAR ELEVATION /(2) IRON ROLLER GATES AND STRUCTURE - ERECTED OVER 5FT WITH NO PLANS OR PERMIT ON FILE. PERMIT NOW REQUIRED FOR SAID CONSTRUCTION.
- Open
CN063014 — CHIMNEY
CHIMNEY - MASONRY FRACTURES WITH OPEN MORTAR JOINTS.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF RODENT INFESTATION AND CONSTRUCTION BEING DONE WITHOUT PERMIT ON FILE.
- Open
CN062034 — REPAIR COPING
FRONT ELEVATION /COPING - OPEN MORTAR JOINTS.
- Open
CN064014 — REPAIR CORNICE
FRONT ELEVATION /CORNICE - OPEN MORTAR JOINTS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING /MOST APARTMENTS - NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN073014 — REPAIR EXTERIOR DOOR
EAST/ NE REAR PORCH - ALL REAR ENTRY DOORS - ROTTING; PAINT PEELING
- Open
BR1072 — PROVIDE FRESH AIR
- Open
BR1001 — OWNER OR LICENSED CONTRACTOR
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO VERIFY OPEN VIOLATIONS.UNABLE TO GAIN ENTRY TO VERIFY COMPLAINTS OF BED BUGS IN 7381 2E AND 7387 1E UNSECURED BACK DOOR.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING - OWNER'S ID SIGN INCOMPLETE, MISSING MAILING ADDRESS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING - OWNER'S ID SIGN INCOMPLETE, MISSING MAILING ADDRESS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINTS OF BED BUGS THROUGHOUT. NO ACCESS TO INSPECT REAR PORCHES OR STAIRS.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING - NOT REGISTERD FOR 2013.
- Open
CN140036 — PIGEONS-UNSANITARY HOUSING
PIGEON WASTE- 7385 REAR PORCH ON ALLEY.
- Open
CN107015 — ILLUMINATE PUBLIC STAIR/HALL
EMERGENCY LIGHTS NOT OPERATING - 7385 INTERIOR STAIRS.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
SMOKE DETECTOR NOT OPERATING 7385 1N.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY NORTH AND SOUTH PORCHES. NO ENTRY MOST UNITS.
- Open
CN070024 — REPAIR PORCH SYSTEM
7385 REAR PORCH (ON ALLEY)- LOOSE AND DEFLECTING DECKING AT 1RST. BOLT LOOSE AT STRINGER TO POST AT 1RST. TOPS OF STRINGERS TO 6X6 CONNECTION- BOLTS MISSING WHERE HOLES DRILLS AND MEMBERS PREPPED FOR ANCHORING. POSTS ANCHORED TO HEADERS WITH NAILS ONLY. OPEN MASONRY POCKETS ALL LEVELS. OBTAIN PERMIT.
- Open
CN107015 — ILLUMINATE PUBLIC STAIR/HALL
EMERGENCY LIGHTS NOT OPERATING - 7385 INTERIOR STAIRS.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
SMOKE DETECTOR NOT OPERATING 7385 1N.
- Open
CN140036 — PIGEONS-UNSANITARY HOUSING
PIGEON WASTE- 7385 REAR PORCH ON ALLEY.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY NORTH AND SOUTH PORCHES. NO ENTRY MOST UNITS.
- Open
CN070024 — REPAIR PORCH SYSTEM
7385 REAR PORCH (ON ALLEY)- LOOSE AND DEFLECTING DECKING AT 1RST. BOLT LOOSE AT STRINGER TO POST AT 1RST. TOPS OF STRINGERS TO 6X6 CONNECTION- BOLTS MISSING WHERE HOLES DRILLS AND MEMBERS PREPPED FOR ANCHORING. POSTS ANCHORED TO HEADERS WITH NAILS ONLY. OPEN MASONRY POCKETS ALL LEVELS. OBTAIN PERMIT.
- Open
CN138056 — DEBRIS, EXCESSIVE
7381-REAR PORCH,JUNK AND REFUSE STORED ON LANDINGS.
- Open
CN140046 — PIGEONS-NESTING
7385-REAR PORCH,PIGON FEECES.
- Open
CN197019 — INSTALL SMOKE DETECTORS
NORTHEAST INTERIOR PORCH NO SMOKE DETECTOR AT TOP
- Open
CN070024 — REPAIR PORCH SYSTEM
SOUTH-EAST PORCH NAILS USED FOR RAILING ANCHORS TO MASONRY,
- Open
CN140036 — PIGEONS-UNSANITARY HOUSING
PIGEONS AND PIGEON WASTE EAST CENTER PORCH
- Open
CN070024 — REPAIR PORCH SYSTEM
EAST CENTER PORCH TAP CONS USED FOR RAILING ANCHORS TO MASONRY, BOLTS REQUIRED. 4X4 COLUMN ROTTING FROM 2 TO 3 STRINGERS, CRACKED AND ROTTING FROM 2 TO 3. 4X4 COLUMN OVER EXTENDED/UNDERSIZED. 4X4 COLUMN SEATED ON SLAB. SOUTH PORCHES INSUFFICIENT STRINGER TO OTHER WOOD MEMBER CONNECTIONS. 4X4 COLUMNS UNDERSIZED AND SEATED ON SLAB. NORTH PORCHES WITH SIMILAR DEFICIENCIES. OBTAIN COMPLETE PLANS AND PERMIT.
- Rodent-related
CN136016 — ROACHES
ROACHES 7385 2 SOUTH AND 3 SOUTH
- Heat-related
CN132016 — HEAT UNIT ADEQUATELY
7385 APT 1 64F DEGREES 11:25 AM HEAT NOT AT TIME OF INSPECTION
- Open
CN070024 — REPAIR PORCH SYSTEM
SOUTHWEST PORCH-STRINGERS NOT BOLTED TO WOOD SUPPORTS ALSO SOUTH EAST PORCH PERMITS NO PLANS REQUIRED
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN064014 REPAIR CORNICE
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN077014 REPAIR FENCE
- Open City violation record — CN131026 REPAIR SCREENS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN073014 REPAIR EXTERIOR DOOR
- Open City violation record — BR1001 OWNER OR LICENSED CONTRACTOR
- Open City violation record — BR1072 PROVIDE FRESH AIR
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN140036 PIGEONS-UNSANITARY HOUSING
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN107015 ILLUMINATE PUBLIC STAIR/HALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN107015 ILLUMINATE PUBLIC STAIR/HALL
- Open City violation record — CN140036 PIGEONS-UNSANITARY HOUSING
- Open City violation record — CN140046 PIGEONS-NESTING
- Open City violation record — CN138056 DEBRIS, EXCESSIVE
- Open City violation record — CN136016 ROACHES
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN140036 PIGEONS-UNSANITARY HOUSING
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
Recently closed / other violations (sample)
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
- Closed / other
CN196019 NO POSTED ADDRESS
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN107015 ILLUMINATE PUBLIC STAIR/HALL
- Closed / other
CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Closed / other
CN140036 PIGEONS-UNSANITARY HOUSING
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN136016 ROACHES
- Closed / other
CN140036 PIGEONS-UNSANITARY HOUSING
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
NC8012 1HR SEP-D.U. AND REST OF BLDG
- Closed / other
CN131036 PROVID SELF CLSING SCREEN DVCE
- Closed / other
CN067014 REPAIR ROOF
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN135016 MICE/RODENTS
- Closed / other
CN136016 ROACHES
Around 7381 N Damen Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:13 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.