Free building report

7369 N DAMEN AVE

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 7369 N Damen Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

53Open City violation records
0Open heat-related City records
2311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (53)

8 of 53 open City violation records are from the last 24 months (since November 2024), shown newest first. 45 older ones are collapsed below — still open, still counted.

  • Open

    CN062014 — PARAPET & COPING

    WEST ELEVATIONS, INCLUDING COURTYARD - FRACTURES, LOOSE AND ERODED MORTAR WITH OPEN COPING JOINTS AT VARIOUS LOCATIONS.14X-3-303.6

  • Open

    CN069034 — REPAIR AREAWAY WALL

    NORTH AND SOUTH AREAWAYS - CRACK AND LOOSE PLASTER/MORTAR .14X-3-305.1.1

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    NOTHR AND SOUTH ELEVATIONS,ALL PORCH SYSYTEMS - LOOSE , BUCKLED AND CRACKED TREADS/DECK BOARDS AT VARIOUS LOCATIONS THRU-OUT.14X-3-303.11

  • Open

    CN131026 — REPAIR SCREENS

    ALL ELEVATIONS - MISSING OR TORN SCREENS.14X-3-303.16

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING. NO ENTRY ,NO RESPONSE . UNABLE TO VERIFY CONDITIONS, SMOKE & CARBON MONOXIDE ALARMS. 14A-1-104.7

  • Open

    CN065034 — REPAIR WINDOW SILLS

    WEST ELEVATIONS, INCLUDING COURTYARD - OPEN SILL JOINTS. 14X-3-303.13

  • Open

    CN064014 — REPAIR CORNICE

    WEST ELEVATIONS INCLUDING COURTYARD - LOOSE AND SHIFTED CORNICE STONES WITH OPEN JOINTS, UNSAFE.14X-3-303.8

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    ALL ELEVATIONS - FRACTURES,LOOSE AND ERODED MORTAR AT VARIOUS LOCATIONS THRU-OUT. PERMIT REQUIRED FOR ALL MASONRY REPAIRS.14X-3-303.6

Show 45 older open City violation records (before November 2024)
  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    ARRANGE FOR INSPECTION / UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS AND OR OCCUPANCY. UNABLE TO VERIFY BEDBUG CONCERN AT UNIT 1 (7379 N.)

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    ARRANGE PREMISE INSPECTION / MOST UNITS UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, AND ALL REAR PORCHES. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF APT.H2 ROACH INFESTED.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, AND ALL REAR PORCHES. UNVERIFIED DETECTORS AND CONDITIONS.

  • Open

    CN104055 — REPUTTY WINDOW PANES

    WEST COURTYARD/NORTH, SOUTH ELEVATIONS - WINDOW TRIM - ROTTING; PAINT PEELING

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    SOUTHEAST - VEHICLE PARKED ON SERVICEWALK - NOT A DESIGNATED PARKING AREA; IN VERY CLOSE PROXIMITY TO REAR PORCH; NO VEHICULAR BARRIERS ERECTED. OBTAIN PERMIT TO ALLOW FOR PARKING ON PRIVATE SERVICEWALKS (NORTH & SOUTH).

  • Open

    CN077014 — REPAIR FENCE

    EAST - CHAIN LINK FENCE - 9'-11" I HEIGHT, TOP RAIL MISSING; BARBED WIRE

  • Open

    CN198019 — FILE BLDG REGISTRATION

    NOT REGISTERED 2017

  • Open

    CN194039 — REMOVE

    SOUTHEAST - VEHICLE PARKED ON SERVICEWALK - NOT A DESIGNATED PARKING AREA; IN VERY CLOSE PROXIMITY TO REAR PORCH; NO VEHICULAR BARRIERS ERECTED. REMOVE. (SEC 7-28-0602)

  • Open

    CN197079 — REPAIR/REPLACE SMOKE DETECTORS

    SMOKE DETECTOR NOT OPERATING TOP OF 7373 FRONT INTERIOR STAIR.SMOKE DETECTOR NOT OOPERATING TOP OF NORTHWEST INTERIOR REAR PORCH.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ACCESS MOST UNITS, PORCHES, BOILER ROOM. UNABLE TO VERIFY OCCUPANCY AND DETECTORS.

  • Open

    CN107015 — ILLUMINATE PUBLIC STAIR/HALL

    LIGHTS NOT OPERATING IN REAR NORTHWEST INTERIOR PORCH SYSTEM.

  • Open

    CN065014 — REPAIR LINTELS

    COURT YARD; RUSTING AND SAGGING LINTELS NUMEROUS LOCATIONS. SOME DETERIORATING MORE SIGNIFICANTLY SEE 7377 AT 2, 7375 AT 2. WEST ELEVATION LINTELS; RUSTED. NUMEROUS LINTELS CAPPED AND CONDITIONS NOT VISIBLE. OBTAIN PERMIT FOR LINTEL REPLACEMENT.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO RESPONSE/ENTRY AT TIME OF INSPECTRION.UNABLE TO GAIN ENTRY TO VERIFY COMPLAINTS ON SR# 131363336,131505275,AND 140111866.UNABLE TO GAIN ENTRY TO VERIFY EXISTING INTERIOR VIOLATIONS.UNABLE TO GAIN NENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION.

  • Open

    CN065014 — REPAIR LINTELS

    WEST ELEVATION 7369 2ND FLOOR AND 7379 1ST FLOOR LINTEL IS RUSTED AND DEFLECTING.PLAN AND PERMIT REQUIRED TO MAKE REPAIRS.

  • Open

    CN073044 — REPAIR EXTERIOR DOOR HARDWARE

    WEST ELEVATION 7373-75 COMMON DOOR MISSING BACKSET ON LOCK.7369 COMMON DOOR DOESN'T STAY SHUT.FRONT GATE DOOR CLOSER MALFUNCTONING.

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    WEST ELEVATION 7377 COMMON ENTRY DOOR BROKEN GLASS PANE.

  • Open

    CN114045 — LIVING AREA - RESIDENT. UNIT

    7369N/ BASEMENT APARTMENT- OVERCROWDED CONDITIONS, WITH 4 INDIVIDUAL SLEEPING ROOMS.

  • Open

    CN190020 — INSPECT CONSTRUCTION WORK

    PERMIT #100303228 ISSUED ON 12/09/2009 TO: REPAIR [6] OPEN WOOD PORCHES & [2] ENCLOSED WOOD PORCHES PER PLANS. PLANS, AND PERMIT NOT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT MOST INTERIOR STAIRWAYS. 7369N/ BASEMENT APARTMENT- NO ENTRY TO INDIVIDUAL SLEEPING ROOMS.

  • Open

    CN065014 — REPAIR LINTELS

    WEST ELEVATION/ 3RD FLOOR LINTELS- RUSTED THRU. PERMIT REQUIRED FOR LINTEL REPLACEMENT.

  • Open

    CN064014 — REPAIR CORNICE

    WEST ELEVATION/ CORNICES- WASHED OUT MORTAR, WITH SOME SECTIONS MISALIGNED.

  • Open

    CN062034 — REPAIR COPING

    WEST ELEVATION/ COPING STONEWORK- WASHED OUT MORTAR.

  • Open

    CN062024 — PARAPET

    WEST ELEVATION/ COURTYARD AREA PARAPET WALL- WASHED OUT MORTAR.

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    WEST ELEVATION/ NORTH AREA WAY EXTERIOR DOOR- PEELING VENEER.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING NOT REGISTRED FROM 2011 THRU 2013.

  • Open

    CN190020 — INSPECT CONSTRUCTION WORK

    PERMIT #100303228 ISSUED ON 12/09/2009 TO: REPAIR [6] OPEN WOOD PORCHES & [2] ENCLOSED WOOD PORCHES PER PLANS. PLANS, AND PERMIT NOT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT MOST INTERIOR STAIRWAYS. 7369N/ BASEMENT APARTMENT- NO ENTRY TO INDIVIDUAL SLEEPING ROOMS.

  • Open

    CN065014 — REPAIR LINTELS

    WEST ELEVATION/ 3RD FLOOR LINTELS- RUSTED THRU. PERMIT REQUIRED FOR LINTEL REPLACEMENT.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    NORTH EAST PORCH WITH SIGNIFICANT LATERAL SWAY. PROVIDE RECENTLY APPROVED PLAN AND RECENTLY ISSUED PERMIT, ARRANGE FOR FINAL INSPECTION OF ALL PORCH REPAIRS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ACCESS TO SOUTH PORCHES AND STAIRS.

  • Open

    CN063014 — CHIMNEY

    CHIMNEY- AT 3 NORTH ELEVATION EAST END, WEST FACE WITH ERODING MORTAR AND OPEN MORTAR JOINTS.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    NORTH ELEVATION AT EAST END AT PORCH- 3RD FLOOR- ERODED MORTAR, OPEN MORTAR JOINTS, FRACTURES, SPALLING BRICK.

  • Open

    CN031013 — FIRE EXTNGSHR REQ, RESDNTL

    EXPIRED FIRE EXTINGUISHER 7375 STAIRWELL.

  • Open

    CN190020 — INSPECT CONSTRUCTION WORK

    ARRANGE FOR FINAL INSPECTION OF PORCHES, HAVE APPROVED PLAN AND ORIGINAL PERMIT ON SITE AT TIME OF INSPECTION.

  • Open

    CN106015 — REPAIR INTERIOR STAIR SYSTEM

    7639 A AND B INTERIOR STAIR WITH LOOSE AND DEFLECTING RAILS AND WORN TREADS. OBTAIN PERMIT.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    SOUTH EXTERIOR PORCHES INSUFFICIENT BEAM TO COLUMN CONNECTIONS - NO ANGLE IRONS. BOLTS WITHOUT WASHERS AND NUTS AT BEAM TO COLUMN CONNECTIONS. INSUFFICIENT LEDGER BOLTS IN NUMBER AND SPACING. PICKETS ON OUTSIDE OF RAILING SYSTEMS BROKEN AND MISSING. INSUFFICIENT RAILING ANCHORS, MISSING MASONRY BOLTS. RAILINGS SEPARATING AT MULTIPLE LOCATIONS. SOUTH CENTER PORCH WITH INSUFFICIENT STRINGER CONSTRUCTION FOR LENGTH OF RUN. UNDERSIZED 2X10 BEAM. NORTHSIDE OF STIARS FOR INTERSECTING JOISTS. COLUMNS AT 1 NOTCHED AND SPLICED AT DECK.SOUTHEAST PORCH WITH OPEN MASONRY POCKETS AND NO STRAPS TO MASONRY AT BEAMS. SOUTH PORCHES INSUFFICIENT BEAM/JOIST CONSTRUCTION AT TOPS AND BOTTOMS OF STAIRS NOT DOUBLED. NORTH PORCHES WITH SAME DEFECTS AND DEFICIENCIES. NORTHEAST PORCH WITH CANTILEVER.NORTH CENTER PORCH WITH MULTIPLE FOOTING AND FOUNDATION DEFECTS, SOME COLUMNS WITH CRUMBLING FOOTINGS, SOME COLUMNS ON SLAB, SOME COLUMNS SEATED OFF CENTER ON UNDERSIZED FOOTINGS. OBTAIN PLANS AND PERMITS FOR ALL PORCH REPAIRS.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    7639 A & B REAR STAIRS MISSING HANGERS, INSUFFICIENT STRINGER ANCHORS, LOOSE RAIL AT GROUND. INSUFFICIENT RAILING ANCHORS. WORN TREADS. UNDERSIZED BEAMS FOR INTERCEDING JOISTS - 2X8 BEAM SPANNING 10'6". GUARDRAILS AT 3 ONLY 36" IN HEIGHT - 42" REQUIRED. OBTAIN PLANS AND PERMIT

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    SOUTH EXTERIOR PORCHES INSUFFICIENT BEAM TO COLUMN CONNECTIONS - NO ANGLE IRONS. BOLTS WITHOUT WASHERS AND NUTS AT BEAM TO COLUMN CONNECTIONS. INSUFFICIENT LEDGER BOLTS IN NUMBER AND SPACING. PICKETS ON OUTSIDE OF RAILING SYSTEMS BROKEN AND MISSING. INSUFFICIENT RAILING ANCHORS, MISSING MASONRY BOLTS. RAILINGS SEPARATING AT MULTIPLE LOCATIONS. SOUTH CENTER PORCH WITH INSUFFICIENT STRINGER CONSTRUCTION FOR LENGTH OF RUN. UNDERSIZED 2X10 BEAM. NORTHSIDE OF STIARS FOR INTERSECTING JOISTS. COLUMNS AT 1 NOTCHED AND SPLICED AT DECK.SOUTHEAST PORCH WITH OPEN MASONRY POCKETS AND NO STRAPS TO MASONRY AT BEAMS. SOUTH PORCHES INSUFFICIENT BEAM/JOIST CONSTRUCTION AT TOPS AND BOTTOMS OF STAIRS NOT DOUBLED. NORTH PORCHES WITH SAME DEFECTS AND DEFICIENCIES. NORTHEAST PORCH WITH CANTILEVER.NORTH CENTER PORCH WITH MULTIPLE FOOTING AND FOUNDATION DEFECTS, SOME COLUMNS WITH CRUMBLING FOOTINGS, SOME COLUMNS ON SLAB, SOME COLUMNS SEATED OFF CENTER ON UNDERSIZED FOOTINGS. OBTAIN PLANS AND PERMITS FOR ALL PORCH REPAIRS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY ANY FRONT INTERIOR STAIRS, NO ENTRY ANY UNITS OR BASEMENT.

  • Open

    CN074014 — SERVICE WALK, PASSAGE, AREAWAY

    NORTH AND SOUTH SERVICE WALKS-BUCKLED AND FRUCTURED CONCRETE.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING-NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS. APT.G3-NO ENTRY, UNABLE TO VERIFY COMPLAINT OF BROKEN WINDOWS, RADIATOR, DOOR KNOB AND MAIL BOXES.

  • Open

    CN140016 — DWELLING CLEAN AND SANITARY

    7369 REAR WEST INTERIOR STAIR SYSTEM UNSANITARY CONDITIONS, DIRT, GARBAGE ODOR STAINED DECKS AND TREADS

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    7369 WEST INTERIOR STAIR SYSTEM REAR LOOSE DEFLECTING UNDERSIZED GUARDRAILS MISSING JOIST HANGERS

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • rodent

    Rodent Baiting/Rat Complaint

  • rodent

    Rodent Baiting/Rat Complaint

Timeline

  1. 311 rodent — Rodent Baiting/Rat Complaint
  2. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  3. Open City violation record — CN064014 REPAIR CORNICE
  4. Open City violation record — CN065034 REPAIR WINDOW SILLS
  5. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  6. Open City violation record — CN131026 REPAIR SCREENS
  7. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  8. Open City violation record — CN069034 REPAIR AREAWAY WALL
  9. Open City violation record — CN062014 PARAPET & COPING
  10. 311 rodent — Rodent Baiting/Rat Complaint
  11. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  12. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  13. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  14. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  15. Open City violation record — CN194039 REMOVE
  16. Open City violation record — CN198019 FILE BLDG REGISTRATION
  17. Open City violation record — CN077014 REPAIR FENCE
  18. Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
  19. Open City violation record — CN104055 REPUTTY WINDOW PANES
  20. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  21. Open City violation record — CN065014 REPAIR LINTELS
  22. Open City violation record — CN107015 ILLUMINATE PUBLIC STAIR/HALL
  23. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  24. Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
  25. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  26. Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
  27. Open City violation record — CN065014 REPAIR LINTELS
  28. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  29. Open City violation record — CN065014 REPAIR LINTELS
  30. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  31. Open City violation record — CN190020 INSPECT CONSTRUCTION WORK
  32. Open City violation record — CN198019 FILE BLDG REGISTRATION
  33. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  34. Open City violation record — CN062024 PARAPET
  35. Open City violation record — CN062034 REPAIR COPING
  36. Open City violation record — CN064014 REPAIR CORNICE
  37. Open City violation record — CN065014 REPAIR LINTELS
  38. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  39. Open City violation record — CN190020 INSPECT CONSTRUCTION WORK
  40. Open City violation record — CN114045 LIVING AREA - RESIDENT. UNIT

Recently closed / other violations (sample)

  • Closed / other

    CN190029 ARRANGE FOR REINSPECTION REGAR

  • Closed / other

    CN064014 REPAIR CORNICE

  • Closed / other

    CN190029 ARRANGE FOR REINSPECTION REGAR

  • Closed / other

    CN104035 MAINTAIN WINDOW

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN078014 ILLUMINATE EXIT AREAS

  • Closed / other

    CN073044 REPAIR EXTERIOR DOOR HARDWARE

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN076044 REPAIR DOWNSPOUT

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    CN104015 REPLCE WINDOW PANES, PLEXGLAS

  • Closed / other

    CN138106 STOP/REMOVE NUISANCE

  • Closed / other

    CN064014 REPAIR CORNICE

  • Closed / other

    CN062034 REPAIR COPING

  • Closed / other

    CN062024 PARAPET

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN114045 LIVING AREA - RESIDENT. UNIT

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN063014 CHIMNEY

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN031013 FIRE EXTNGSHR REQ, RESDNTL

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN136016 ROACHES

  • Closed / other

    CN135016 MICE/RODENTS

Around 7369 N Damen Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:45 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com