All open City violation records (34)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 14, 2015. All 34 are collapsed below — still open, still counted.
Show 34 older open City violation records (before November 2024)
- Open
CN197087 — CARB MONOX DETECT IN RESID
BASEMENT APT. MISSING CARBON MONOXIDE DETECTOR.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING- THIRD FLOOR APT. NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN131026 — REPAIR SCREENS
REPAIR REPLACE DEFECTIVE SCREENS THROUGHOUT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR EXTERIOR WOODEN THREE STORY PORCH,COLUMNS ONLY HAVE 12 IN. SPLICE,AND TWO BOLTS.4X4 COLUMNS USED ON STAIR STRINGERS GRADE THRU THIRD FLOOR.VERTICAL 6X6 BEAMS TO COLUMNS NOT STRAPPED TOGETHER,ONLY NAILED TOGETHER.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
SUBMIT PLANS AND OBTAIN A PERMIT TO AUTHORIZED ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO ORIGIONAL STATE.
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT A PERMIT AND PLANS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING- NO OWNER'S ID SIGN POSTED.
- Heat-related
NC10022 — HEATING PLANT SEPARATION
BASEMENT- BOILER/ FURNACE AND HOT WATER HEATER ROOM- PIPE, DUCT AND VARIOUS PENETRATIONS THROUGHOUT. CEILING CONSTRUCTED OF FIBER BOARD- NO FIRE RATING. NO DOOR ON HEATING PLANT ROOM. BASEMENT ILLEGAL APARTMENT ALSO HAS FURNACE IN FRONT CLOSET SERVING 1RST FLOOR APARTMENT- FOLDING CLOSET DOORS, NO FIRE RATING.
- Open
CN102015 — INT WALL/CEILING PEELING PAINT
BASEMENT ILLEGAL APARTMENT BATHROOM WITH WATER DAMAGE/ STAINS, LOOSE JOINT COMPOUND AND TAPE. FRONT LOBBY CEILING WITH FRACTURES AND WATER DAMAGE.
- Open
CN104075 — WINDOW REPAIR FOR AIR SEEPAGE
BASEMENT ILLEGAL APARTMENT BEDROOM WINDOW- LOOSE IN TRACK, AIR INFILTRATION, FRACTURED AND LOOSE TRIM.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
BASEMENT - SMOKE DETECTOR NOT IN SERVICE.
- Open
CN197087 — CARB MONOX DETECT IN RESID
NO CARBON MONOXIDE DETECTOR- BASEMENT.
- Rodent-related
CN136016 — ROACHES
BASEMENT, 1RST AND 3RD FLOORS- ROACH INFESTATION.
- Open
PL160017 — REMV OBSTR FROM DRAINAGE SYSTM
1RST FLOOR APARTMENT REAR BATHROOM- CLOGGED TOILET.
- Open
EL0018 — DEFECTIVE OUTLETS
APARTMENT 3- LIVING ROOM AND FRONT BEDROOM OUTLETS NOT IN SERVICE.
- Open
NC2071 — WORK NOT ALLOWED
APARTMENTS AT 1 AND 3- PARTIONS ERECTED IN LIVING ROOM, CREATING ADDITIONAL BEDROOM. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ELECTRIC) INSTALLED WITH OUT A PERMIT.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
POST I.D.
- Heat-related
CN046013 — UNAPPROVED HEATING DEVICE
BASEMENT ILLEGAL APARTMENT- SPACE HEATERS AND STOVE TOP/ OVEN USED FOR HEAT. NO PERMANENT HEATING SYSTEM INSTALLED TO SERVE BASEMENT APARTMENT.
- Heat-related
CN132016 — HEAT UNIT ADEQUATELY
3RD FLOOR APARTMENT- NO HEAT. 59 DEGREES DINING ROOM, 58 DEGREES LIVING ROOM, 55 DEGREES FRONT BED ROOM.
- Open
CN132046 — SAFE WORKING CONDITIONS
THIRD FLOOR APARTMENT- FURNACE NOT IN SERVICE, NOT OPERATING. ELECTRICITY NOT FUNCTIONING TO HEATING UNIT (ELECTRICITY NOT OPERATING FRONT OF APARTMENT IN LIVING ROOM, FURNACE CLOSET, FRONT BEDROOM).
- Open
CN104075 — WINDOW REPAIR FOR AIR SEEPAGE
FRONT BED ROOM WINDOW NOT CLOSING, SASH WILL NOT COME DOWN.
- Open
CN065014 — REPAIR LINTELS
WEST ELEVATION LINTELS SIGNIFICANT SAGGING, RUST BLEADING THROUGH PAINT. NORTH AND SOUTH ELEVATIONS AT WEST ENDS- LINTELS SAGGING AND RUSTING. NORTH ELEVATION AT 3 LARGE LINTEL RUSTING AND SAGGING. OBTAIN PERMIT.
- Open
CN061014 — REPAIR EXTERIOR WALL
BOWING BRICK, SHIFTING BRICK AND FRACTURES OFF OF LINTELS- MOST NOTABLE AT 3.
- Open
CN138066 — DEMO DEBRIS
GARAGE- FILLED WITH DEMO DEBRIS, DRYWALL, WOOD, GARBAGE, MATRESSES.
- Open
CN079014 — REPAIR/REBUILD GARAGE OR SHED
GARAGE- SPALLING BRICK AND ERODING MORTAR VARIOUS LOCATIONS THROUGHOUT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR 3 STORY PORCH- COLUMNS ON SLAB. LOOKOUT BEAM AND COLUMN CONNECTIONS FASTENED/ ANCHORED WITH NAILS ONLY. COLUMNS OVER CUT AT FIRE CUTS- MORE THAN 2''. LOOKOUT BEAMS SPAN 8' 8''. RIM JOISTS ANCHORED WITH NAILS ONLY. RAILS ANCHORED WITH NAILS AND/ OR SCREWS ONLY. STRINGERS AT SOME LOCATIONS ANCHORED WITH NAILS ONLY. SOME JOISTS ANCHORED WITH NAILS ONLY. LANDING JOISTS OVER HAND LANDING BEAM BY 3 1/2''. RISER HEIGHTS VARY - 6 1/2'', 8'', 1 1/2'', 7'', 8 1/2''. LOOSE DECKING. 4X4 COLUMNS WITH 1/2 LAPP JOINT SPLICES AS LITTLE AS 4'' AND FASTENED WITH 1 BOLT. OUT OF PLUMB, BOWED AND WARPED OVER EXTENDED 4X4 COLUMNS. CRACKED/ SPLIT TREADS. OBTAIN PLAN AND PERMIT.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
BASEMENT ILLEGAL CONVERSION. APARTMENT CONSTRUCTED- KITCHEN, BEDROOM, BATHROOM, LIVINGROOM, PARTITIONS. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE (PEMIT AND PLAN REQUIRED FOR DECONVERSION).
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO INSPECT MOST APARTMENTS AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY.
- Open
CN138106 — STOP/REMOVE NUISANCE
REAR PORCH - BBQ GRILLS ON 2ND, 3RD FLOOR DECKS.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 BEAMS NOTCHED, TOENAILED TO 6X6 COLUMNS; UNDERSIZED 4X4 COLUMNS; 2X8 JOISTS SPAN 9'-2"; SPLICE JOINTS AT 4X4 COLUMN ONLY 4"-8" WITH ONLY ONE BOLT. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH.
- Open
CN136026 — INSECTS
2ND FLOOR APARTMENT - INSECTS IN BEDROOM
- Open
CN197087 — CARB MONOX DETECT IN RESID
2ND FLOOR APARTMENT - CARBON MONOXIDE DETECTOR - MISSING
- Open
EL0020 — SUPPORT FIXTURES
INTERIOR STAIRWELL - 2ND FLOOR - LOOSE WALL FIXTURE; UNSECURED.
- Open
CN197019 — INSTALL SMOKE DETECTORS
2ND FLOOR APARTMENT; INTERIOR STAIRWELL - SMOKE DETECTOR - MISSING
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- rodent
Rodent Baiting/Rat Complaint
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN131026 REPAIR SCREENS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN079014 REPAIR/REBUILD GARAGE OR SHED
- Open City violation record — CN138066 DEMO DEBRIS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN104075 WINDOW REPAIR FOR AIR SEEPAGE
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
- Open heat-related City violation record — CN046013 UNAPPROVED HEATING DEVICE
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open City violation record — EL0018 DEFECTIVE OUTLETS
- Open City violation record — PL160017 REMV OBSTR FROM DRAINAGE SYSTM
- Open City violation record — CN136016 ROACHES
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN104075 WINDOW REPAIR FOR AIR SEEPAGE
- Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
- Open heat-related City violation record — NC10022 HEATING PLANT SEPARATION
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — EL0020 SUPPORT FIXTURES
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN136026 INSECTS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
Recently closed / other violations (sample)
- Closed / other
CN070024 REPAIR PORCH SYSTEM
Around 7359 N Seeley Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 5:46 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.