Free building report
734 N Western Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 734 N Western Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (12)
6 of 12 open City violation records are from the last 24 months (since November 2024), shown newest first. 6 older ones are collapsed below — still open, still counted.
- Open
CN061014 — REPAIR EXTERIOR WALL
SOUTH AND EAST ELEVAIONS - FRACTURES AND LOOSE MORTAR AT VARIOUS LOCATIONS.14X-3-303.6
- Open
CN062014 — PARAPET & COPING
SOUTH AND EAST ELEVATIONS - FRACTURES, LOOSE AND ERODED MORTAR WITH SHIFTED BRICKS AND COPINGS, UNSAFE, OVER PUBLIC WALK. PERMIT FOR PARAPET REBUILDS AND ALL MASONRY REPAIRS REQUIRED,
- Open
CN065034 — REPAIR WINDOW SILLS
SOUTH AND EAST ELEVATIONS - OPEN SILL JOINTS.14X-3-303.13
- Open
CN063014 — CHIMNEY
SOUTH ELEVATION, CHIMNEY - ERODED MORTAR , LOOSE BRICKS WITH MISSING CAP.14X-3-303.10
- Open
CN061074 — PROTECT SIDEWALK DURING CONST
SOUTHEAST ELEVATION - IMMEDIATELY PROVIDE EMERGENCY SCAFFOLDING OR PROTECTIVE CANOPY OVER THE PUBLIC WAY FOR THE PROTECTION OF PEDESTRIANS FROM UNSAFE BUILDING CONDITIONS AND PREVENT IMMINENT HARM TO PEOPLE OR PROPERTY. A BUILDING PERMIT APPLICATION COVERING THE SCOPE OF THE EMERGENCY REPAIR MUST BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS ON THE NEXT BUSINESS DAY. A PERMIT APPLICATION FOR THE SCAFFOLDING/CANOPY MUST BE SUBMITTED TO THE DEPARTMENT OF BUILDINGS WITHIN 3 BUSINESS DAYS OF ERECTION. THE DEPARTMENT OF TRANSPORTATION MAY NOT ISSUE A PERMIT FOR USE OF THE PUBLIC WAY TO INSTALL SCAFFOLDING/CANOPY UNLESS A PERMIT FOR THE SCAFFOLDING/CANOPY HAS BEEN OBTAINED FROM THE BUILDING DEPARTMENT. (14A-4-401.1.1, 14A-4-401.1.2, 14A-4-404.16 THROUGH 14A-4-404.16.5, 14A-4-404.22.3 AND 14B-33-3306)
- Open
CN065014 — REPAIR LINTELS
SOUTHEAST ELEVATION - RUSTED LINTEL/BEAMS.14X-3-303.1.1
Show 6 older open City violation records (before November 2024)
- Open
CN193110 — VACANT BUILDING - REGISTER
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
SOUTH-EAST CORNER / STORE FRONT GLASS PANE - SEVERELY CRACKED AND OVERHANGING OVER PUBLIC SIDEWALK.
- Open
CN062024 — PARAPET
SOUTH ELEVATION / PARAPET WALL - BULGING AND SHIFTING MASONRY. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.
- Open
CN061014 — REPAIR EXTERIOR WALL
SOUTH ELEVATION / EXTERIOR WALL / ABOVE 3RD FLOOR BAY WINDOWS / MASONRY - SEVERELY BULGING AND SHIFTING OVER PUBLIC SIDEWALK. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.SOUTH-EAST CORNER / ABOVE 2ND FLOOR / MASONRY - SEVERELY CRACKED AND SHIFTING OVER PUBLIC WAY. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.SOUTH-EAST CORNER / BOTTOM OF BAY WINDOWS'S TOWER / MASONRY - SEVERELY CRACKED AND SAGGING OVER PUBLIC SIDEWALK. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.2404 W. / ABOVE EXTERIOR ENTRANCE / LARGE SECTION OF STONEWORK - CRACKED AND SAGGING. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.
- Open
CN065014 — REPAIR LINTELS
SOUTH ELEVATION / GRAFE TO 3RD FLOOR / MULTIPLE LOCATIONS / METAL LINTELS - RUSTED AND BENT. PERMIT ONLY REQUIRED FOR METAL LINTELS REPLACEMENT.
- Open
CN061074 — PROTECT SIDEWALK DURING CONST
DEPARTMENT OF PROVIDE PROTECTIVE CANOPY OVER PUBLIC SIDEWALK. PERMIT ISSUED BY TRANSPORTATION REQUIRED FOR SUCH INSTALLATION.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
- Open City violation record — CN063014 CHIMNEY
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN062014 PARAPET & COPING
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN193110 VACANT BUILDING - REGISTER
- Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
Recently closed / other violations (sample)
- Closed / other
CN062024 PARAPET
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN061074 PROTECT SIDEWALK DURING CONST
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN198019 FILE BLDG REGISTRATION
Around 734 N Western Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 12:45 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.