Free building report

6657 N Newgard Ave

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 6657 N Newgard Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

21Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (21)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from August 30, 2022. All 21 are collapsed below — still open, still counted.

Show 21 older open City violation records (before November 2024)
  • Open

    CN067024 — REPAIR EAVES

    NORTH AND WEST ELEVATIONS - ROTTED EAVES WITH PEELING PAINT.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS.

  • Open

    CN193000 — MAINTAN BLDG IN SAFE CONDITION

  • Open

    CN193019 — REPAIR/WRECK DANGER RESID PREM

  • Open

    CN193029 — WATCHMAN

  • Open

    CN002081 — SUBMIT FOR APPROVAL PLANS

  • Open

    CN193110 — VACANT BUILDING - REGISTER

  • Open

    CN196039 — POST OWNER INFO ON ABDN BLDG

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    1447-19 FRONT STAIRWAY MISSING SMOKE DETECTOR AT TOP.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    NORTH AND WEST ELEVATIONS/ WINDOW SILLS-WASHED-OUT MORTAR,EAST ELEVATION 1ST FLOOR AND BASEMENT - FRACTURED SILLS.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING NOT REGISTER FROM 1990 THRU 2009

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    1417-19 REAR PORCH STORAGE ON ALL FLOORS BLOCKING EGRESS.

  • Open

    CN063024 — CHIMNEY CAPPING

    CHIMNEY MISSING CAP.

  • Open

    CN063014 — CHIMNEY

    CHIMNEY WASHED OUT MORTAR

  • Open

    CN104015 — REPLCE WINDOW PANES, PLEXGLAS

    EAST ELEVATION BASEMENT WINDOW BROKEN GLASS.1419 APARTMENT 1 AND BASEMENT GUT REHAB WORK EXPOSED STUBS,FLOOR JOIST,PLUMBING WORK,ELECTRICAL WORK-PROVIDE PLANS AND PERMIT.

  • Open

    CN074024 — PROVIDE GUARD RAIL 42 IN HIGH

    REAR BASEMENT ENTRY MISSING GUARDRAIL.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    REAR STAIRS TOO BASEMENT MISSING HANDRAIL.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH 1417 & 1419 (1) 6X6 AND 4X6 COLUMNS RESTING ON CONCRETE BLOCKS ON TOP OF SLAB.(2) FOUNDATION STATUS UNKNOWN.(3)6X6 AND 4X6 COLUMNS OVER NOTCHED.(4)LAP JOINTS ON COLUMNS WITH LARGE GAPS AND ONLY 1 OR 2 BOLTS.(5) SOME LOOKOUT BEAMS OVER SPANNED.(6)SOME LOOKOUT BEAMS MISSING TIE STRAPS.(7)SOME LOOKOUT BEAMS RESTING ON DOOR AND WINDOW JAMS.(8)INADEQUATE BEAM TO COLUMN CONNECTION.(9)2X8 JOIST OVER SPANNED.(10)STRINGERS INADEQUATELY SUPPORTED.(11) STAIR TREADS TOO SMALL.(12)GUARDRAILS LOOSE AND DEFLECT UNDER PRESSURE.(13)DECKING AT 1ST FLOOR FIRE DAMAGED WITH HOLES-1423,6657 REAR PORCH (1) 4X4 COLUMN RESTING ON CONCRETE SLAB AND USED FOR SUPPORT OVER 12 FEET HIGH.(2)2X8 JOIST OVER SPANNED.(3)LEDGER BEAM INADEQUATELY CONNECTED TO BUILDING.(4)MISSING JOIST HANGERS.(5)STRINGERS INADEQUATELY SUPPORTED.(6)STAIR TREADS TOO SMALL.(7)GUARDRAILS TOO LOW.PLANS AND PERMIT REQUIRED FOR BOTH REAR PORCHES.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    ALL ELEVATIONS /VARIOUS LOCATIONS THRU-OUT FROM GRADE THRU 3RD FLOOR SPALLING BRICKS AND WASHED OUT MORTAR.

  • Open

    CN074014 — SERVICE WALK, PASSAGE, AREAWAY

    REAR SERVICE WALK FRACRURED AND BUCKLED CONCRETE CAUSING TRIP HAZARD.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    MORTOR JOINTS OPEN AT WINDOW SILL; VARIOUS LOCATION; ALL ELEVATORS AND OVER DOORS; FRACTURE AT REAR NE CORNER UNDER 1ST WINDOW.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  2. Open City violation record — CN067024 REPAIR EAVES
  3. Open City violation record — CN196039 POST OWNER INFO ON ABDN BLDG
  4. Open City violation record — CN193110 VACANT BUILDING - REGISTER
  5. Open City violation record — CN002081 SUBMIT FOR APPROVAL PLANS
  6. Open City violation record — CN193029 WATCHMAN
  7. Open City violation record — CN193019 REPAIR/WRECK DANGER RESID PREM
  8. Open City violation record — CN193000 MAINTAN BLDG IN SAFE CONDITION
  9. Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
  10. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  11. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  12. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  13. Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
  14. Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
  15. Open City violation record — CN063014 CHIMNEY
  16. Open City violation record — CN063024 CHIMNEY CAPPING
  17. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
  18. Open City violation record — CN198019 FILE BLDG REGISTRATION
  19. Open City violation record — CN065034 REPAIR WINDOW SILLS
  20. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  21. Open City violation record — CN061014 REPAIR EXTERIOR WALL

Recently closed / other violations (sample)

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    CN136026 INSECTS

  • Closed / other

    CN190020 INSPECT CONSTRUCTION WORK

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN065034 REPAIR WINDOW SILLS

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN063024 CHIMNEY CAPPING

  • Closed / other

    CN063014 CHIMNEY

  • Closed / other

    CN104015 REPLCE WINDOW PANES, PLEXGLAS

  • Closed / other

    CN065014 REPAIR LINTELS

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

Around 6657 N Newgard Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:23 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com