All open City violation records (18)
1 of 18 open City violation records are from the last 24 months (since November 2024), shown newest first. 17 older ones are collapsed below — still open, still counted.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF BED BUG INFESTATION WITHIN 3C AND 3E. (14A-1-104.7)
Show 17 older open City violation records (before November 2024)
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCHES SOUTHEAST PORCH 6X6 COLUMNS RESTING ON 8 INCH PIERS THAT ARE RESTING ON TOP OF CONCRETE SLAB. FOUNDATION STATUS UNKNOWN 2X8 JOIST OVER SPANNED (11 FEET) 35 INCHES OF CLEAR TRAVEL AT LANDINS. CENTER PORCH- 6X6 COLUMNS RESTING ON 8 INCH PIERS NO SPREAD FOOTING, 32 INCHES OF CLEAR TRAVEL AT LANDING, WEST PORCH- 4X4 COULMNS RESTING ON CONCRETE SLAB, FOUNDATION STATUS UNKNOWN 4X4 AND 6X6 COLUMNS RESTING ON WOOD BLOCKS ON TOP OF ROOF. LOOKOUT BEAMS MISSING TIE STRAPS INADEQUATE BEAM TO COLUMN CONNECTION 2X8 JOIST OVER SPANNED (16FEET) HANDRAILS LOOSE AT LANDING HANDRAILS TOO HIGH (38 INCHES) ALL STAIR TREADS TOO SMALL ONLY 9 1/4 INCHES STRINGERS INADEQUATELY SUPPORTED, PALNS AND PERMIT REQUIRED FOR ALL PORCHES ALSO LEDGER NOT BOLTED
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
REAR PORCHES BICYLES STORE ON PORCH BLOCKING EGRESS.
- Open
CN131016 — SCREEN OUTER DOORS, WINDOWS
REARYARD/ ALL FLOORS MISSING WINDOWS SCREENS
- Open
CN074024 — PROVIDE GUARD RAIL 42 IN HIGH
REAR COURTYARD/ROOF TOP WITH PLANTS ON TOP MISSING GUARDRAIL.ALSO GUARDRAILS AT BASEMENT STAIRS TOO LOW AND ANGLE TO COME SLAB
- Open
CN070014 — REPAIR EXTERIOR STAIR
REAR STAIRS TO BASEMENT MISSING HANDRAILS(CENTER SET)
- Open
CN065014 — REPAIR LINTELS
NOETH ELEVATION/ 2ND AND 3RD FLOOR LINTELS RUSTED AND SAGGING LINTELS ABOVE PUBLIC WALKWAY/PERMIT REQUIRED FOR REAPIRS
- Open
CN062024 — PARAPET
NORTH ELEVATION/PARAPET WALL-SPALLING AND MISSING BRICK AND WASHED OUT MORTAR PERMIT REQUIRED TO REPLACE BRICKS.
- Open
CN061074 — PROTECT SIDEWALK DURING CONST
PROTECT PUBLIC WALKWAY DURING REPAIR OF LINTELS AND PARAPET WALLS
- Open
CN031023 — FIRE EXTNGSHR RECHARGE & TAG
ALL FIRE EXTINGUISHER WITH EXPIRED TAGS OF TAGS ARE MISSING
- Open
CN107035 — MAINTAIN EXIT SIGN ILLUMINATED
1641/2ND AND 3RD FLOORS EXIT SIGNS NOT ILLUMINATED
- Open
CN104025 — MAINTAIN WINDOW SASH
REAR COURTYARD/ALL FLOORS ROTTED WINDOW SASHES
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED FROM 2007 THRU 2008.
- Open
CN062024 — PARAPET
NORTH ELEVATION/PARAPET-SPALLING BRICK AND WASHED OUT MORTAR
- Open
CN065014 — REPAIR LINTELS
NORTH ELEVATION/2ND AND 3RD FLOORS-SAGGING AND RUSTED LINTELS OVER PUBLIC WALK WAY.
- Open
CN065034 — REPAIR WINDOW SILLS
NORTH AND WEST ELEVATION AT 2&3-SILLS WASHED OUT MORTAR.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
PROVIDE PLANS AND PERMIT FOR PORCH REPAIRS THAT WERE PERFORMED.
- Open
CN031013 — FIRE EXTNGSHR REQ, RESDNTL
1633 FIRE EXTINGUISHER TAG OUT OF DATE.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN104025 MAINTAIN WINDOW SASH
- Open City violation record — CN107035 MAINTAIN EXIT SIGN ILLUMINATED
- Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
- Open City violation record — CN131016 SCREEN OUTER DOORS, WINDOWS
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN031013 FIRE EXTNGSHR REQ, RESDNTL
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN065034 REPAIR WINDOW SILLS
Recently closed / other violations (sample)
- Closed / other
CN101025 INT WALL/CEILING CHIP PLASTER
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN132016 HEAT UNIT ADEQUATELY
- Closed / other
CN046013 UNAPPROVED HEATING DEVICE
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN107035 MAINTAIN EXIT SIGN ILLUMINATED
- Closed / other
CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Closed / other
CN070014 REPAIR EXTERIOR STAIR
- Closed / other
CN061074 PROTECT SIDEWALK DURING CONST
- Closed / other
CN062024 PARAPET
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
- Closed / other
CN104025 MAINTAIN WINDOW SASH
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN074024 PROVIDE GUARD RAIL 42 IN HIGH
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN062024 PARAPET
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
CN031013 FIRE EXTNGSHR REQ, RESDNTL
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN138026 USE SANITARY REFUSE CONTAINERS
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
Around 6657 N Clark St
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 12:16 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.