Free building report

660 W WRIGHTWOOD AVE

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 660 W Wrightwood Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

20Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
1311 building (24 mo)

What rat complaints mean →

All open City violation records (20)

9 of 20 open City violation records are from the last 24 months (since November 2024), shown newest first. 11 older ones are collapsed below — still open, still counted.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    GARAGE CEILING - SEVERELY WEATHERED, SAGGING, BROKEN / MISSING SECTIONS OF WATER DAMAGED DRWALL IN VARIOUS LOCATIONS. 14X-3-304.3

  • Open

    CN075014 — GRADE AND DRAIN LOT

    PARKING LOT - SEWER DRAING IS SINKING WITH LARGE POT HOLES CREATING A TRIP HAZARD AND FLOODING ISSUES. 14X-3-302.2

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    CEILING - IS WATER DAMAGED WITH PEELING PAINT AND SMALL HOLE. 14X-3-304.3

  • Open

    CN103015 — REPAIR FLOOR

    FLOORS - CARPETED FLOORS SINKING / SOFT VOIDS WHEN DEFLECTED. 14X-3-304.4

  • Open

    NC6012 — 1HR PUB.CORRIDOR IN MULT. D.U.

    CORRIDOR FIRE DOORS - PROPED OPEN WITHOUT FAIL-SAFE SYSTEM INSTALLED. KEEP DOORS CLOSED OR PROVIDE FAIL-SAFE SYSTEM. LAUNDRY ROOM / DOOR - PROPED OPE AT THE TIME OF INSPECTION. 14B-10.1020.1

  • Open

    NC5012 — CLASS B DOOR IN STAIRWELL

    FIRE DOORS - NOT LATCHING IN VARIOUS LOCATIONS. 14A-7-716.1

  • Open

    CN194029 — PROVIDE

    STAIRWELL DOOR LOCKED AND REQUIRES KEY FOR RE-ENTRY ONTO FLOORS, NO FAIL-SAFE DOOR UNLOCKING SYSTEM INSTALLED. PER 13-196-084

  • Open

    CN031023 — FIRE EXTNGSHR RECHARGE & TAG

    FIRE EXSTINGUISHER - ALL TAGS HAVE EXPIRED AUGUST 2024. 14X-5-504.5

  • Open

    CN197039 — RELOCATE SMOKE DETECTOR

    SMOKE DETECTOR - RELOCATE SO THAT IT IS ABLE TO BE TESTED / REPLACED WHEN NEEDED. 1ST FLOOR / LAUNDRY ROOM SMOKE DETECTOR - WAS INSTALLED OVER THE DOOR. RELOCATE. 14X-5-504.8

Show 11 older open City violation records (before November 2024)
  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED DETECTORS.

  • Open

    CN075014 — GRADE AND DRAIN LOT

    PARKING GARAGE UNDER 5 STORY BUILDING - CONCRETE AND ASPHALT AROUND SEWER - COLLAPSING.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    PARKING GARAGE UNDER 5 STORY BUILDING - CEILING - VARIOUS LOCATIONS MISSING DRYWALL AND EXPOSED JOISTS.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    REPAIR FIRE RECALL

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    CLEAN MACHINE ROOM OUT

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    PERFORM CATEGORY 1 TEST

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    CLEAN PIT FROM WATER

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    INSTALL DOOR RESTRICTOR

  • Open

    CN132046 — SAFE WORKING CONDITIONS

    UNITS 209 AND 211 AND MULTIPLE OTHER UNITS. NEW BASE BOARD ELECTRIC HEAT INSTALLED. TENANTS NOT ABLE TO TURN HEAT ON, HEAT SOURCE OUT OF SERVICE AT TIME OF INSPECTION.

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    UNITS 209, 211 AND MULTIPLE OTHER UNITS - MISSING CARBON MONOXIDE DETECTORS.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    REMOVE NONE ELEVATOR ITEMS FROM MACHINE ROOM

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • building

    Building Violation

Timeline

  1. Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
  2. Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
  3. Open City violation record — CN194029 PROVIDE
  4. Open City violation record — NC5012 CLASS B DOOR IN STAIRWELL
  5. Open City violation record — NC6012 1HR PUB.CORRIDOR IN MULT. D.U.
  6. Open City violation record — CN103015 REPAIR FLOOR
  7. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  8. Open City violation record — CN075014 GRADE AND DRAIN LOT
  9. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  10. 311 building — Building Violation
  11. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  12. Open City violation record — CN075014 GRADE AND DRAIN LOT
  13. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  14. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  15. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  16. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  17. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  18. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  19. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  20. Open City violation record — CN132046 SAFE WORKING CONDITIONS
  21. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

Recently closed / other violations (sample)

  • Closed / other

    CN107015 ILLUMINATE PUBLIC STAIR/HALL

  • Closed / other

    CN107015 ILLUMINATE PUBLIC STAIR/HALL

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN065034 REPAIR WINDOW SILLS

  • Closed / other

    CN190029 ARRANGE FOR REINSPECTION REGAR

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    CN132046 SAFE WORKING CONDITIONS

  • Closed / other

    CN132016 HEAT UNIT ADEQUATELY

  • Closed / other

    CN132046 SAFE WORKING CONDITIONS

  • Closed / other

    CN132016 HEAT UNIT ADEQUATELY

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

Around 660 W Wrightwood Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:45 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com