Free building report

6439 N Richmond St

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 6439 N Richmond St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

47Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (47)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from September 12, 2022. All 47 are collapsed below — still open, still counted.

Show 47 older open City violation records (before November 2024)
  • Open

    EL1816 — ADD RECEPTACLES

    ADD RECEPTACLES OUTLETS IN APARTMENTS WHERE REQUIRED TO PREVENT CORD USAGE.

  • Open

    EL1827 — RESTORE EXIT AND EM

    BATTERY LIGHTS UNAPPROVED, INOPERABLE VARIOUS AREAS, UNMAINTAINED, INSUFFICIENT. DANGEROUS AND HAZARDOUS

  • Open

    EL1823 — INSTALL COVERS

    OPEN BOXES BASEMENT. CLOSE WHERE REQUIRED. DANGEROUS AND HAZARDOUS

  • Open

    PL239010 — ENGAG LIC & BOND PLMBNG CNTRC

    ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR

  • Open

    EL1824 — INSTALL ILLUMINATION

    INSTALL OPERABLE, SUFFICIENT ILLUMINATION AT ALL EXTERIOR ENTRIES, INTERIOR STAIRS, BASEMENT AND WHERE REQUIRED

  • Open

    EL1833 — SECURE RACEWAY

    UNSUPPORTED RACEWAYS EXTERIOR STAIR AND BASEMENT AREAS. SECURE WHERE REQUIRED

  • Open

    CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU

    MISSING SECTIONS FIRE SEPARATION ALL BASEMENTS THROUGHOUT PROPERTY 14X-5-502.3

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    UNIT 2E 6445 MISSING CARBON MONOXIDE DETECTOR. INSTALL WORKING CARBON MONOXIDE DETECTORS WITHIN ALL SPACES WHERE FOSSIL FUELS ARE USED 14X-5-504.9.3

  • Open

    PL237004 — INDIRECT CONN.FOR WATER SUPPLY

    WATER SUPPLY TO BOILER SYSTEM AT BASEMENT IS DIRECTLY CONNECTED WITHOUT ANY MEANS OF BACKFLOW PROTECTION. DANGEROUS AND HAZARDOUS

  • Open

    PL232011 — OBTAIN PERMIT FOR PLUMBING

    OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING, OR USING PLUMBING SYSTEM

  • Open

    EL1856 — SUPPORT OUTLET AND BOX

    UNSUPPORTED BOXES EXTERIOR STAIRS AND BASEMENT AREAS. SECURE WHERE REQUIRED

  • Open

    EL1886 — Violation

    UNAPPROVED FLEXIBLE METAL CONDUIT BASEMENT AREAS, REMOVE WHERE REQUIRED 14E-3-348.10

  • Open

    EL1875 — INSTALL GFCI'S

    INSTALL GFIC PROTECTION KITCHEN, BATH, BASEMENT, EXTERIOR, WET LOCATIONS

  • Open

    EL1822 — EXPOSED WIRING FIXTURES

    EXPOSED WIRING LIGHT FIXTURES AT BASEMENT AREAS. REMOVE WHERE REQUIRED, DANGEROUS AND HAZARDOUS

  • Open

    EL1885 — Violation

    ALL EXTERIOR LIGHT FIXTURES, BOXES, FITTINGS, RACEWAYS MUST BE SUITABLE FOR WET LOCATIONS 14E-1-110.3

  • Open

    EL1817 — CONTINUITY OF RACEWAYS

    ELECTRICAL TROUGH SECTIONS NOT ATTACHED TO EQUIPMENT AT BASEMENTS. ELECTRICAL CONDUITS RUSTED COMPLETELY THROUGH AT EXTERIOR. ENSURE GROUND CONTINUITY WHERE REQUIRED THROUGHOUT. DANGEROUS AND HAZARDOUS

  • Open

    EL1823 — INSTALL COVERS

    OPEN BOXES BASEMENT AREAS. CLOSE WHERE REQUIRED THROUGHOUT PREMISES, DANGEROUS AND HAZARDOUS

  • Open

    EL1839 — CORRODED CONDUIT & EQUIP

    CORRODED RACEWAYS AND BOXES EXTERIOR AND BASEMENT. REPLACE WHERE REQUIRED

  • Open

    EL1884 — SEE INSPECTOR COMMENTS

    PROVIDE ONE LINE DIAGRAMS AND LOAD CALULATIONS FOR ELECTRICAL SERVICES AND FEEDERS. 14E-2-215.5, 14E-2-220.40

  • Open

    EL1806 — PROPER SIZE GRD ELECTRODE COND

    NO VISIBLE WATER GROUND. ENSURE SERVICES GROUNDED IN APPROVED MANNER DANGEROUS AND HAZARDOUS

  • Open

    EL1801 — DEFECTIVE SERVICE

    ELECTRICAL SERVICE CONDUCTORS DETERIORATED. SERVICE RACEWAY CORRODED. MAIN DISCONNECT APPEARS SMOKE/ FIRE DAMAGED. LIVE FRONT DISTRIBUTION. ENSURE SERVIVES IN APPROVED CONDITION DANGEROUS AND HAZARDOUS

  • Open

    EL1886 — Violation

    PROVIDE ALL REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES, AND EQUIPMENT. NEW PANELS IN BASEMENT. SOME MODIFICATIONS BASEMENT. CIRCUITRY MODIFICATIONS BUILDING. MISCELLANEOUS WORK EXTERUIOR. MISCELLANEOUS WORK INTERIOR. NO PERMITS. INSUFFICIENT PERMITS. NO INSPECTIONS. 14A-5-505.2

  • Open

    EL1886 — Violation

    PROVIDE PERMITS TO CORRECT VIOLATIONS AND FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES, AND EQUIPMENT. NEW PANELS BASEMENT. SOME MODIFICATIONS BASEMENT. CIRCUITRY MODIDICATIONS BUILDING. MISCELLANEOUS WORK EXTERIOR. MISCELLANEOUS WORK INTERIOR. NO PERMITS. INSUFFICIENT PERMITS. NO INSPECTIONS. 14A-4-404.6 PREVIOUS WORK AND REQUIRED NEW WORK FOLLOW CODE ARTICLE 570 THROUGHOUT.

  • Open

    EL1886 — Violation

    PROVIDE WALL SWITCH CONTROLLED ILLUMINATION IN HABITABLE ROOMS AT APARTMENTS 14E-5-570.9

  • Open

    EL1811 — ADD BRANCH CIRCUITS

    ADD CIRCUITS IN APARTMENTS WHERE REQUIRED TO PREVENT OVERLOAD

  • Open

    NC2071 — WORK NOT ALLOWED

    STEEL PICKET FENCE OVER 5' REDUCE HEIGHT.REMOVE,OR OBTAIN A PERMIT (14A-4-401)

  • Open

    CN062034 — REPAIR COPING

    6445N - SOUTH ELEVATION[COURTYARD] /COPING - FRACTURED, WITH SECTION MISSING.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    6439N - NORTHWEST CORNER /EXTERIOR WALL - BULGING SHIFTED BRICKS, WITH WASHED OUT MORTAR. PERMIT REQUIRED FOR REPAIRS.

  • Open

    CN132046 — SAFE WORKING CONDITIONS

    6439 APT 1W /RADIATORS - 100 DEGRESS, SCALDING HAZARD.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    SOUTH EAST, NORTH EAST AND NORTH WEST PORCHES; STRINGERS AND RAILS ANCHORED WITH NAILS ONLY. ROTTING, LOOSE AND DEFLECTING RAILS. CENTER STRINGER COLUMNS ONLY 4X4. GUARD RAILS ONLY 32'' IN HEIGHT. TREADS WORN AND ONLY 9 1/4'' DEEP. RISERS AS HIGH AS 8 1/4''. OPEN MASONRY BEAM POCKETS. BEAM POCKET BRICK; FRACTURED, SHIFTING, ERODING MORTAR, SPALLING. BEAMS IN POCKETS INSTALLED 1 BRICK ABOVE LINTELS. ROTTING TREADS. NORTH EAST AND NORTH WEST PORCHES; SINGLE 2 X 8 STRINGER HEADERS SPAN 6' 6''. NORTH EAST AND NORTH WEST PORCHES; ROTTING DECKING. SOUTH EAST PORCH ROTTING PORCH ROOF DECKING AND OUTSIDE JOIST. NORTH EAST AND NORTH WEST PORCHES ROTTING JOISTS AND DECKING. NORTH WEST PORCH ROTTING STRINGER AFTER 2 AND ROTTING HEADER JOIST FOR 3. OBTAIN PLAN AND PERMIT FOR PORCHES.

  • Open

    PL157047 — STOP LEAKING WATER

    6439 1W LEAK BENEATH KITCHEN SINK.

  • Rodent-related

    CN136016 — ROACHES

    6439 1W ROACHES.

  • Open

    CN103015 — REPAIR FLOOR

    6439 1W HARDWOOD FLOORS WORN, DEFICIENT FINISH.

  • Open

    CN165017 — FLOOR, KIT & BATH NON-ABSORB

    6439 1W KITCHEN FLOOR; WORN HARDWOOD FLOORS, NO FINISH REMAINS, SUSTAINING WATER DAMAGE.

  • Open

    CN044013 — PIPE OPENING W/NONCOMBUST MATL

    6439 BASEMENT STORAGE ROOM AND LAUNDRY ROOM; PIPE PENETRATIONS, OPPENINGS FOR COPPER AND IRON PIPES.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    NO SMOKE DETECTOR UNIT 6439 1W.

  • Open

    CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU

    6439 BASEMENT STORAGE ROOM AND LAUNDRY ROOM CEILINGS; WATER DAMAGED, COLLAPSED PLASTER AND LATH, EXPOSED JOISTS AND UNDERSIDE OF FIRST FLOOR FLOORING.

  • Open

    CN102015 — INT WALL/CEILING PEELING PAINT

    6439 UNIT 1W; FLAKING PAINT AND PLASTER DINING ROOM, LIVING ROOM, BED ROOM AND KITCHEN WALLS VARIOUS LOCATIONS.

  • Open

    CN104035 — MAINTAIN WINDOW

    VARIOUS WINDOWS WEST, NORTH, SOUTH ELEVATIONS AND COURT YARD INCLUDING BASEMENT (WHERE NEW REPLACEMENT WINDOWS HAVE NOT BEEN INSTALLED) WINDOWS; ROTTING FRAMES AND SASHES, LOOSE PANES AND MISSING PUTTY. UNIT 6439 1W DINING ROOM WINDOW PANE FRACTURED.

  • Open

    CN062034 — REPAIR COPING

    COURT YARD NORTH COPING; FRACTURES, SPALLING, CRUMBLING COPING STONES TOWARD CENTER.

  • Open

    CN062024 — PARAPET

    COURT YARD NORTH WEST AND SOUTH WEST PARAPET WALLS BOWED, SHIFTING BRICK, BUCKLING, FRACTURES, OPEN MORTAR JOINTS. NORTH ELEVATION WEST END SPALLING BRICK, ERODING MORTAR, OPEN MORTAR JOINTS.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    LIMESTONE SILLS WEST ELEVATION AND COURT YARD; FRACTURES, SHIFTED VARIOUS LOCATIONS. BASEMENT WOOD WINDOW SILLS ROTTING. UNIT 6439 WOOD SILLS IN DINING ROOM ROTTING.

  • Open

    CN064014 — REPAIR CORNICE

    WEST ELEVATION LIMESTONE CORNICE SOUTH END; FRACTURED, SHIFTED, SPALLED, CRUMBLED SECTIONS. COURT YARD VARIOUS LOCATIONS FRACTURED, SHIFTING LIMESTONE.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    WEST ELEVATION AND COURT YARD ELEVATIONS; FRACTURES, OPEN MORTAR JOINTS OFF OF LINTELS. WEST ELEVATION STEP FRACTURES, FRACTURES VARIOUS LOCATIONS. COURT YARD FRACTURES VARIOUS LOCATIONS. COURT YARD SOUTH WEST CORNER; STEP FRACTURES. 6445 ENTRY IN COURT YARD; VERTICAL LIMESTONE FLAKING STAIRWELL WINDOWS IS SHIFTING, FRACTURED, BULGING OUT/ LEANING OUT, UNSECURED, FALL HAZARD.6439 COURTYARD AT WEST ANGLE OF BAY; FRACTURES, SHIFTING BRICK. 6439 FRONT ENTRY LIMESTONE FRACTURED, SHIFTING, SEPARATING. NORTH AND SOUTH ELEVATIONS; FRACTURES AND SPALLING BRICK VARIOUS LOCATIONS INCLUDING AROUND PORCH AND BASEMENT AREAS. LIMESTONE CONDITIONS THROUGHOUT ARE POOR.

  • Open

    CN065014 — REPAIR LINTELS

    WEST ELEVATION AND COURT YARD ELEVATIONS; RUSTING AND SAGGING LINTELS VISIBLE WHERE NOT CAPPED (WHERE LINTELS ARE CAPPED MASONRY CONDITIONS ARE CONSISTENT WITH DETERIORATING LINTELS). OBTAIN PERMIT.

  • Open

    PL170017 — PRV FLOOR DRAIN WITH METAL STR

    6439 BASEMENT STORAGE ROOM FLOOR DRAIN IS OPEN; NO COVER/ STAINER.

  • Open

    CN140046 — PIGEONS-NESTING

    REAR PORCHES; PIGEON FOULING.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — EL1811 ADD BRANCH CIRCUITS
  2. Open City violation record — EL1886
  3. Open City violation record — EL1886
  4. Open City violation record — EL1886
  5. Open City violation record — EL1801 DEFECTIVE SERVICE
  6. Open City violation record — EL1806 PROPER SIZE GRD ELECTRODE COND
  7. Open City violation record — EL1884 SEE INSPECTOR COMMENTS
  8. Open City violation record — EL1839 CORRODED CONDUIT & EQUIP
  9. Open City violation record — EL1823 INSTALL COVERS
  10. Open City violation record — EL1817 CONTINUITY OF RACEWAYS
  11. Open City violation record — EL1885
  12. Open City violation record — EL1822 EXPOSED WIRING FIXTURES
  13. Open City violation record — EL1875 INSTALL GFCI'S
  14. Open City violation record — EL1886
  15. Open City violation record — EL1856 SUPPORT OUTLET AND BOX
  16. Open City violation record — PL232011 OBTAIN PERMIT FOR PLUMBING
  17. Open City violation record — PL237004 INDIRECT CONN.FOR WATER SUPPLY
  18. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  19. Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
  20. Open City violation record — EL1833 SECURE RACEWAY
  21. Open City violation record — EL1824 INSTALL ILLUMINATION
  22. Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
  23. Open City violation record — EL1823 INSTALL COVERS
  24. Open City violation record — EL1827 RESTORE EXIT AND EM
  25. Open City violation record — EL1816 ADD RECEPTACLES
  26. Open City violation record — NC2071 WORK NOT ALLOWED
  27. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  28. Open City violation record — CN062034 REPAIR COPING
  29. Open City violation record — CN132046 SAFE WORKING CONDITIONS
  30. Open City violation record — CN140046 PIGEONS-NESTING
  31. Open City violation record — PL170017 PRV FLOOR DRAIN WITH METAL STR
  32. Open City violation record — CN065014 REPAIR LINTELS
  33. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  34. Open City violation record — CN064014 REPAIR CORNICE
  35. Open City violation record — CN065034 REPAIR WINDOW SILLS
  36. Open City violation record — CN062024 PARAPET
  37. Open City violation record — CN062034 REPAIR COPING
  38. Open City violation record — CN104035 MAINTAIN WINDOW
  39. Open City violation record — CN102015 INT WALL/CEILING PEELING PAINT
  40. Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU

Recently closed / other violations (sample)

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN063014 CHIMNEY

  • Closed / other

    NC2071 WORK NOT ALLOWED

  • Closed / other

    CN074014 SERVICE WALK, PASSAGE, AREAWAY

  • Closed / other

    CN131016 SCREEN OUTER DOORS, WINDOWS

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN063014 CHIMNEY

  • Closed / other

    CN074014 SERVICE WALK, PASSAGE, AREAWAY

  • Closed / other

    CN131016 SCREEN OUTER DOORS, WINDOWS

Around 6439 N Richmond St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 5:38 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com