All open City violation records (13)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from August 16, 2016. All 13 are collapsed below — still open, still counted.
Show 13 older open City violation records (before November 2024)
- Open
CN065034 — REPAIR WINDOW SILLS
EAST - WINDOW SILLS - WASHED OUT MORTAR
- Open
CN104055 — REPUTTY WINDOW PANES
EAST - WINDOW TRIM - ROTTING
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
WEST/2ND FLOOR/#6441 - WINDOW - HOLE IN PANE; POSSIBLY FOR VENTING
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCHES. UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN070014 — REPAIR EXTERIOR STAIR
NORTH ELEVATION AT 6442 ENCLOSED STAIR SYSTEM WITH THE FOLLOWING DEFECTS, NO BOLTS STRINGERS, WINDER TO SUPPORT POSTS AND TO BUILDING, 4X4 SUPPORT COLUMNS OVER SPAND 14'; AT THIRD FLOOR WINDERS WEAK, SUPPORT COLUMN WEAK, 2ND AND 3RD FLOOR LANDINGS DECKING DRY ROTTED, 1ST FLOOR LANDING FORMED CONCRETE SLAB CRUMBLING AT STAIRS. PLANS AND PERMIT REQUIRED.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH SYSTEM WITH THE FOLLOWING DEFECTS, 2X6 RIDGE BOARDS IMPROPERLY INSTALLED ON STRINGERS (INSTALLED ON OUTSIDE INSTEAD OF INSIDE) 318 BOLTS USED TO SECURE TO STRINGERS UNDERSIZED, 1/4 INCH ANGLE BRACKETS INSTALLED AT BEAM CONNECTIONS UNDERSIZED 6X6 COLUMN NORTH WEST ELEVATION TWISTING AT ROOF. PLANS AND PERMITS REQUIRED FOR REPAIRS
- Open
CN070024 — REPAIR PORCH SYSTEM
SR#801592630 NORTH WEST ENCLOSED PORCH STRINGERS NOT BOLTED TO EXTERIOR WALL 3RD FLOOR GUARDRAILS TO LOW APROX. 36' -CONCRETE PLATFORM ON 1ST FLOOR DETERIORATING AT EDGE OF STEPS-PROVIDE REPAIR PERMIT.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
PROVIDE FULL INTERIOR ACCESS TO VERIFY SAFETY DETECTORS AND OCCUPANCY
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
MISSING PICKETS INTERIOR STAIRS 6439.
- Open
CN070024 — REPAIR PORCH SYSTEM
PORCH SYSTEM: 1.) NW STRINGERS NOT BOLTED, RAILS GRADE TO 1ST. LOOSE. STRINGERS 2ND TO 3RD SCABED. CONCRETE PLATFORM AT 1ST FLOOR DETERIORATING AT EDGE OF STEPS. 2.) NE IMPROPER FOUNDATIONS COLUMNS ERECTED ON CONCRETE SLABS. 8X8 COLUMNS AND LOOKOUTS HAVE GAPS 1/2 TO 3/4" AT VARIOUS LOCATIONS, AND MISSING METAL TIES. RAILS ARE 34" HIGH SHOULD BE 42". RAIL IS LOOSE AT 2ND FLOOR. 3.) SE STRINGERS NOT BOLTED TO WALLS OR COLUMNS. MISSING JOIST HANGERS. MISSING PICKETS VARIOUS LOCATIONS. PICKET SPCING IS OVER 4 1/2". OBTAIN A PERMIT FOR REPAIRS.
- Open
EL0084 — SEE INSPECTOR COMMENTS
PROVIDE WEATHER PROOF BOXES AND WEATHER PROOF FIXTURES FOR PORCH AREA'S CONDUCTORS AND ELECTRICAL EQUIPMENT SHALL BE SUITABLE FOR LOCATION AND TEMPERATURE 18-27-110.11
- Open
EL0019 — DEFECTIVE FIXTURES
IN ALL STAIRWAYS CORRIDORS AND COMMON AREA'S
- Open
EL0025 — SYSTEM III
IN ALL STAIRWAYS CORRIDORS AND COMMON AREA'S OF BUILDING
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- rodent
Rodent Baiting/Rat Complaint
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — EL0025 SYSTEM III
- Open City violation record — EL0019 DEFECTIVE FIXTURES
- Open City violation record — EL0084 SEE INSPECTOR COMMENTS
Recently closed / other violations (sample)
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN197087 CARB MONOX DETECT IN RESID
- Closed / other
CN073044 REPAIR EXTERIOR DOOR HARDWARE
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN061034 FLAKY INTERIOR PAINT
- Closed / other
CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Closed / other
CN103015 REPAIR FLOOR
- Closed / other
CN102015 INT WALL/CEILING PEELING PAINT
- Closed / other
CN101015 REPAIR INTERIOR WALLS/CEILING
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN138056 DEBRIS, EXCESSIVE
- Closed / other
CN197087 CARB MONOX DETECT IN RESID
- Closed / other
CN138106 STOP/REMOVE NUISANCE
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN070024 REPAIR PORCH SYSTEM
Around 6439 N Newgard Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:30 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.