Free building report
6438 N Mozart St
Winter habitability score Many open City violation records and/or complaint activity
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 6438 N Mozart St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (35)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 3, 2014. All 35 are collapsed below — still open, still counted.
Show 35 older open City violation records (before November 2024)
- Open
CN073044 — REPAIR EXTERIOR DOOR HARDWARE
1ST FLOOR APARTMENT - REAR SCREEN DOOR , BROKEN AT LATCH .
- Rodent-related
CN134016 — RATS
REAR BASEMENT BOILER AND STORAGE ROOMS ,STOCKPILED BUILDING MATERIALS . RATS AND RAT HARBORAGE .
- Heat-related
NC10012 — HEATING PLANT ENCLOSURE
REAR BASEMENT BOILER AND STORAGE ROOMS ,EXPOSED WOOD WALL AND CEILING FRAMING . FIRE AND SAFETY HAZARD .
- Open
CN063014 — CHIMNEY
REAR BASEMENT BOILER AT BASE OF BRICK CHIMNEY , LARGE HOLE IN CHIMNEY ( APPROXIMATELY 16 INCHES ROUND ) , VENT PIPE REMOVED AND NOT SEALED . HEALTH AND SAFETY HAZARD TO TENANTS AND OCCUPANTS .
- Open
CN197087 — CARB MONOX DETECT IN RESID
REAR BASEMENT BOILER ROOM - MISSING CARBON MONOXIDE DETECTOR .
- Open
EL0056 — SUPPORT OUTLET AND JBOX
BASEMENT BOILER ROOM , LOOSE AND HANGING CONDUIT , BOXES AND WIRES .
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
REAR BASEMENT LAUNDRY ROOM STAIRS , MISSING HANDRAILS AND GUARDRAILS .
- Open
NC8012 — 1HR SEP-D.U. AND REST OF BLDG
BOILER ROOM WALL SEPARATING BASEMENT DWELLING UNIT , EXPOSED WOOD STUDS . NOT PROPER FIRE SEPARATION .
- Open
PL154027 — SUPPLY HOT WTR MIN TEMP 120DEG
1ST FLOOR APARTMENT - KITCHEN HOT WATER SUPPLIED AT 150 DEGREES . SEVERE SCALDING HAZARD .
- Open
EL0023 — INSTALL COVERS
1ST FLOOR APARTMENT - MISSING ALL SWITCH COVERS .
- Open
CN105015 — REPAIR DOOR, INT.
1ST FLOOR APARTMENT - BATHROOM AND BEDROOM DOORS RUB ON FRAMES AND WILL NOT CLOSE .
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
1ST FLOOR APARTMENT - FRONT BATHROOM , WATER DAMAGED PLASTER ON CEILINGS AND WALLS .
- Open
CN101025 — INT WALL/CEILING CHIP PLASTER
1ST FLOOR APARTMENT - FRONT BATHROOM HALL CLOSET , CHIPPED PAINT AND PLASTER ON CEILINGS AND WALLS .
- Open
CN073054 — REPAIR EXTERIOR DOOR, RESET
1ST FLOOR APARTMENT - REAR DOOR FRAME , COLD AIR SEEPAGE , GAPS AND CRACKS , DRAFTY .
- Heat-related
CN132016 — HEAT UNIT ADEQUATELY
1ST FLOOR APARTMENT -ROOM TEMPERATURE 48 DEGREES . HEATING SYSTEM IS ON AT TIME OF INSPECTION , HEAT IS INSUFFICIENT .
- Open
CN132046 — SAFE WORKING CONDITIONS
1ST FLOOR APARTMENT - FURNACE NEEDS SERVICING , HEAT IS INSUFFICIENT .
- Open
PL154027 — SUPPLY HOT WTR MIN TEMP 120DEG
1ST FLOOR APARTMENT - KITCHEN HOT WATER SUPPLIED AT 150 DEGREES . SEVERE SCALDING CONDITION EXIST OVER 130 DEGREES . HAZARD TO TENANTS AND OCCUPANTS .
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING - NOT REGISTERED ALL YEARS , 1990 THROUGH 2013 .
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING - NO OWNER'S I.D. SIGN POSTED .
- Open
CN104035 — MAINTAIN WINDOW
ALL ELEVATIONS AND FLOORS , WOOD WINDOW FRAMES ROTTED WITH FLAKING PAINT .
- Open
CN065024 — MAINTAIN PROJECTIONS
FRONT FIRST FLOOR IRON BALCONETTE RAILS RUSTED WITH FLAKING PAINT .
- Open
CN131026 — REPAIR SCREENS
ALL ELEVATIONS AND FLOORS , WINDOW SCREENS , TORN ,LOOSE AND MISSING .
- Open
NC5042 — SELF-CLOSE CLASS B FIRE DOOR
BASEMENT APARTMENT , FRONT AND REAR DOORS , SIX PANEL WOOD AND NOT FIRE RATED . FIRE AND SAFETY HAZARD .
- Open
CN105055 — INSTALL DOOR VIEWING DEVICE
BASEMENT APARTMENT - MISSING VIEWING DEVICES .
- Open
CN190020 — INSPECT CONSTRUCTION WORK
PERMIT # 100464436 ISSUED 4/5/2013 FOR " LEGALIZE GROUND FLOOR APARTMENT AND CONVERT 3 DWELLING UNITS TO 4 DWELLING UNITS " , NO PLANS AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATIONS COMPLIED WITHOUT MAKING PROPERTY " NEW ANNUAL BUILDING " .
- Open
CN190020 — INSPECT CONSTRUCTION WORK
PERMIT # 100419191 ISSUED 12/05/2011 FOR " REPLACE REAR OPEN WOOD PORCH AS PER PLANS " , NO PLANS AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION .
- Open
CN190020 — INSPECT CONSTRUCTION WORK
PERMIT # 100454577 ISSUED 8/21/2012 FOR " TUCKPOINTING - NO STRUCTURAL WORK " NO PERMIT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION
- Rodent-related
CN134056 — RAT PROOF METAL FLOOR DRAINS
REAR BRICK GARAGE - MISSING FLOOR DRAIN COVERS .
- Open
EL0019 — DEFECTIVE FIXTURES
REAR BRICK GARAGE - LIGHTS AND SWITCH , OUT OF SERVICE .
- Open
CN076034 — REPAIR GUTTER
REAR PORCH GUTTER , RUSTED , LEAKING AND FLAKING PAINT .
- Open
CN032035 — NO GASOLINE(LPG) STORAGE
MOTORCYCLE STORED UNDER WOOD FRAME PORCH STAIRS . FIRE AND SAFETY HAZARD .
- Open
CN017012 — INTERIOR FINISH FIRERESISTANCE
BASEMENT , REMOVE NON-FIRE RATED CEILING TILES AND METAL GRID FROM BASEMENT APARTMENT AND REAR LAUNDRY ROOM .
- Open
CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU
REAR BASEMENT BOILER AND STORAGE ROOMS , BROKEN ,LOOSE AND FALLING PLASTER WITH EXPOSED WOOD FRAMING . FIRE AND SAFETY HAZARD .
- Open
CN138066 — DEMO DEBRIS
REAR BASEMENT BOILER AND STORAGE ROOMS ,STOCKPILED BUILDING MATERIALS . FIRE AND SAFETY HAZARD .
- Open
CN138056 — DEBRIS, EXCESSIVE
REAR BASEMENT BOILER AND STORAGE ROOMS ,STOCKPILED JUNK AND DEBRIS . FIRE AND SAFETY HAZARD .
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN138056 DEBRIS, EXCESSIVE
- Open City violation record — CN138066 DEMO DEBRIS
- Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Open City violation record — CN017012 INTERIOR FINISH FIRERESISTANCE
- Open City violation record — CN032035 NO GASOLINE(LPG) STORAGE
- Open City violation record — CN076034 REPAIR GUTTER
- Open City violation record — EL0019 DEFECTIVE FIXTURES
- Open City violation record — CN134056 RAT PROOF METAL FLOOR DRAINS
- Open City violation record — CN190020 INSPECT CONSTRUCTION WORK
- Open City violation record — CN190020 INSPECT CONSTRUCTION WORK
- Open City violation record — CN190020 INSPECT CONSTRUCTION WORK
- Open City violation record — CN105055 INSTALL DOOR VIEWING DEVICE
- Open City violation record — NC5042 SELF-CLOSE CLASS B FIRE DOOR
- Open City violation record — CN131026 REPAIR SCREENS
- Open City violation record — CN065024 MAINTAIN PROJECTIONS
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — PL154027 SUPPLY HOT WTR MIN TEMP 120DEG
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
- Open City violation record — CN073054 REPAIR EXTERIOR DOOR, RESET
- Open City violation record — CN101025 INT WALL/CEILING CHIP PLASTER
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN105015 REPAIR DOOR, INT.
- Open City violation record — EL0023 INSTALL COVERS
- Open City violation record — PL154027 SUPPLY HOT WTR MIN TEMP 120DEG
- Open City violation record — NC8012 1HR SEP-D.U. AND REST OF BLDG
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — EL0056 SUPPORT OUTLET AND JBOX
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN063014 CHIMNEY
- Open heat-related City violation record — NC10012 HEATING PLANT ENCLOSURE
- Open City violation record — CN134016 RATS
- Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
Recently closed / other violations (sample)
- Closed / other
NC2021 PERMIT REQUIRED - CONTRACTOR
- Closed / other
CN063014 CHIMNEY
- Closed / other
NC8012 1HR SEP-D.U. AND REST OF BLDG
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN062024 PARAPET
- Closed / other
EL0036 COVER OUTLETS AND JBS
- Closed / other
CN197019 INSTALL SMOKE DETECTORS
- Closed / other
CN197087 CARB MONOX DETECT IN RESID
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
CN101015 REPAIR INTERIOR WALLS/CEILING
- Closed / other
CN190020 INSPECT CONSTRUCTION WORK
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
Around 6438 N Mozart St
- West Ridge community area: search another address
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 2:28 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.