Free building report

633 W Addison St

Winter habitability score Open City violation records are on file — read the list, not just the score

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 633 W Addison St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

10Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (10)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from May 17, 2024. All 10 are collapsed below — still open, still counted.

Show 10 older open City violation records (before November 2024)
  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    ARRANGE FOR INSPECTION / UNABLE TO VERIFY INTERIOR CONDITIONS, DETECTORS AND OR OCCUPANCY. UNABLE TO VERIFY 3RD FLOOR CEILING DAMAGE AND PREVIOUS VIOLATIONS. REINSPECTION REQUIRED FOR REMOVAL OF PREVIOUS VIOLATIONS.

  • Open

    CN061024 — SUBMIT 2 COPY STRUCTURAL RPT

    THIS REPORT IS TO FOCUS ON THE WEST ELEVATION BALCONY AND ALL OF ITS COMPONENTS BOTH STRUCTURAL AND ORNAMENTAL. THE MAIN BEAM UNDER THE TERRA COTTA CLADDING IS TO BE CRITICALLY EXAMINED AS WELL.

  • Open

    CN066034 — REPAIR BALCONY

    WEST ELEVATION ... 2CD TO 3RD LEVEL BALCONY.*THERE ARE 6 CONCRETE COLUMNS EXTENDING UPWARD FROM THE OUTER BALCONY WALL THAT SUPPORT THE MASONRY AT THE 3RD LEVEL OF THIS BUILDING. THESE COLUMNS ARE SEVERELY STRESS FRACTURED AND SPALLED. AN ATTEMPT TO ABATE THE CONTINUED STRESS FRACTURING HAS BEEN ATTEMPTED WITHOUT PLANS OR PERMIT BY INSTALLING STEEL BANDS AROUND THE PILLARS THEMSELVES. PLANS AND PERMIT REQUIRED FOR REPAIRS.*AT THE MASONARY HEADER BEAM WHERE THE COLUMN TOPS ARE AFFIXED IS A MAIN STRUCTURAL BEAM CLAD WITH TERRA COTTA PIECES THAT ARE LOOSE / SHIFTED / DISPLACED. DANGEROUS AND HAZARDOUS. PLANS AND PERMIT REQUIRED TO MAKE REPAIRS TO THE TERRA COTTA AND ANY / ALL ELEMENTS OF THE BEAM WITH WHICH THE TERRA COTTA PIECES ARE ATTACHED.

  • Open

    CN061024 — SUBMIT 2 COPY STRUCTURAL RPT

    THIS REPORT IS TO FOCUS ON THE WEST ELEVATION BALCONY AND ALL OF ITS COMPONENTS BOTH STRUCTURAL AND ORNAMENTAL. THE MAIN BEAM UNDER THE TERRA COTTA CLADDING IS TO BE CRITICALLY EXAMINED AS WELL.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    2 PORCHES. BOTH 3 STORIES. ONE AT THE EAST ELEVATION. ONE AT THE SOUTH ELEVATION.*THE STAIR STRINGERS ARE OVER NOTCH CUT.*THE STAIR BANISTERS ARE TOO LOW AT 30".*THE PORCH DECK BANISTERS ARE TOO LOW AT 34".*THERE ARE NO INTERMEDIATE BANISTER POSTS.*THE STAIR FLIGHTS ARE NAILED, NOT BOLTED TO THE PORCH STRUCTURE. *THERE ARE NO DESCERNABLE FOOTINGS FOR THE COLUMNS THAT EXTEND BELOW THE FROST LINE. *THERE ARE NO METAL TIE BACK CLIPS FASTENING THE BANISTER SECTION TO THE PORCH STRUCTURE.*THE STRUCTURAL COLUMNS THEMSELVES ARE UNDERSIZED 4"X4" DIMENSIONAL LUMBER.*PLANS AND PERMIT REQUIRED FOR PORCH UPGRADES.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    2 PORCHES. BOTH 3 STORIES. ONE AT THE EAST ELEVATION. ONE AT THE SOUTH ELEVATION.*THE STAIR STRINGERS ARE OVER NOTCH CUT.*THE STAIR BANISTERS ARE TOO LOW AT 30".*THE PORCH DECK BANISTERS ARE TOO LOW AT 34".*THERE ARE NO INTERMEDIATE BANISTER POSTS.*THE STAIR FLIGHTS ARE NAILED, NOT BOLTED TO THE PORCH STRUCTURE. *THERE ARE NO DESCERNABLE FOOTINGS FOR THE COLUMNS THAT EXTEND BELOW THE FROST LINE. *THERE ARE NO METAL TIE BACK CLIPS FASTENING THE BANISTER SECTION TO THE PORCH STRUCTURE.*THE STRUCTURAL COLUMNS THEMSELVES ARE UNDERSIZED 4"X4" DIMENSIONAL LUMBER.*PLANS AND PERMIT REQUIRED FOR PORCH UPGRADES.

  • Open

    CN066034 — REPAIR BALCONY

    WEST ELEVATION ... 2CD TO 3RD LEVEL BALCONY.*THERE ARE 6 CONCRETE COLUMNS EXTENDING UPWARD FROM THE OUTER BALCONY WALL THAT SUPPORT THE MASONRY AT THE 3RD LEVEL OF THIS BUILDING. THESE COLUMNS ARE SEVERELY STRESS FRACTURED AND SPALLED. AN ATTEMPT TO ABATE THE CONTINUED STRESS FRACTURING HAS BEEN ATTEMPTED WITHOUT PLANS OR PERMIT BY INSTALLING STEEL BANDS AROUND THE PILLARS THEMSELVES. PLANS AND PERMIT REQUIRED FOR REPAIRS.*AT THE MASONARY HEADER BEAM WHERE THE COLUMN TOPS ARE AFFIXED IS A MAIN STRUCTURAL BEAM CLAD WITH TERRA COTTA PIECES THAT ARE LOOSE / SHIFTED / DISPLACED. DANGEROUS AND HAZARDOUS. PLANS AND PERMIT REQUIRED TO MAKE REPAIRS TO THE TERRA COTTA AND ANY / ALL ELEMENTS OF THE BEAM WITH WHICH THE TERRA COTTA PIECES ARE ATTACHED.

  • Open

    RF301091 — PRV PLUGGED/CAPPED

  • Open

    RF301031 — ACCESS TO ROOF

  • Open

    RF301041 — ARRANGE FOR INSPECTION

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  2. Open City violation record — CN066034 REPAIR BALCONY
  3. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  4. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  5. Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
  6. Open City violation record — CN066034 REPAIR BALCONY
  7. Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
  8. Open City violation record — RF301041 ARRANGE FOR INSPECTION
  9. Open City violation record — RF301031 ACCESS TO ROOF
  10. Open City violation record — RF301091 PRV PLUGGED/CAPPED

Recently closed / other violations (sample)

  • Closed / other

    BR1001 OWNER OR LICENSED CONTRACTOR

  • Closed / other

    BR2010 NO ENTRY

Around 633 W Addison St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 4:20 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com