Free building report

5300 S HYDE PARK BLVD

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 5300 S Hyde Park Blvd, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

44Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
2311 building (24 mo)

What rat complaints mean →

All open City violation records (44)

4 of 44 open City violation records are from the last 24 months (since November 2024), shown newest first. 40 older ones are collapsed below — still open, still counted.

  • Open

    NC5042 — SELF-CLOSE CLASS B FIRE DOOR

    5300 NORTH & SOUTH STAIRWELLS / DOORS - TAGS MISSING. 14A-7-716.1

  • Open

    CN133016 — CARPETING

    5300 STAIRWELL / CARPET - SAGGING , PULLING & TEARING AWAY FROM STAIRS. 14X-3-304.4

  • Rodent-related

    CN136016 — ROACHES

    5300 APT 302 / ROACHES - OBSERVED AT TIME OF INSPECTION.PROVIDE PROFESSIONAL EXTERMINATION SERVICES AND ABATE ROACH INFESTATION. VIOLATION WILL NOT BE COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. 14X-3-308

  • Open

    CN104035 — MAINTAIN WINDOW

    EAST ELEVATION / FRAMES - ROTTING WITH CHIPPING & FLAKING PAINT. 14X-3-303.13

Show 40 older open City violation records (before November 2024)
  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    NO ENTRY INTO 1ST FLOOR, COMMON SPACES, RESIDENTIAL STAIRWELLS, APARTMENTS OR MECHANICAL SPACES TO VERIFY EGRESS, EXIT SIGNS, FIRE EXTINGUISHERS, CARBON MONOXIDE DETECTORS, SMOKE DETECTORS, INTERIOR STRUCTURAL, COSMETIC OR ENVIRONMENTAL CONDITIONS

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF APTS. - NO ENTRY, UNVERIIFIED DETECTORS AND CONDITIONS.

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    1ST TON 3RD FLOOR / INTERIOR HALLWAY LEADING FROM NORTH TO SOUTH HALLWAYS / DOORS ARE PADLOCKED AND OR SCREWED SHUT.

  • Open

    CN078014 — ILLUMINATE EXIT AREAS

    EXIT LIGHTS THROUGHOUT NOT WORKING AT TIME OF INSPECTION.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    NORTH ELEVATION-1ST FLOOR STEP CRACKS.WEST ELEVATION - 1ST FLOOR WASHED OUT MORTAR.REAR RETAINING WALL CRACKED .

  • Open

    CN104015 — REPLCE WINDOW PANES, PLEXGLAS

    5306 FRONT 1ST FLOOR WINDOW BROKEN.

  • Open

    CN074024 — PROVIDE GUARD RAIL 42 IN HIGH

    REAR PORCH GRADE TO 3RD FLOOR .1ST FLOOR BY WINDERS NO GUARD RAIL.

  • Open

    CN064014 — REPAIR CORNICE

    NORTH ELEVATION - CORNICE OPEN MORTAR JOINTS.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    NORTH ELEVATION 1ST AND 2ND FLOOR WINDOW SILLS OPEN MORTAR JOINTS.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    NORTH ELEVATION-1ST FLOOR STEP CRACKS.WEST ELEVATION - 1ST FLOOR WASHED OUT MORTAR.REAR RETAINING WALL CRACKED .

  • Open

    CN197088 — CARB MONOX DETECT IN HOTEL

    5306 BASEMENT LAUNDRY ROOM NO CARBON MONOXIDE.

  • Open

    CN107015 — ILLUMINATE PUBLIC STAIR/HALL

    5306 1ST FLOOR FRONT CEILING LIGHT NOT ON AT TIME OF INSPECTION.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    5308 FRONT INTERIOR STAIRS 3RD FLOOR NO SMOKE DETECTOR

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    5306 1ST,2ND AND 3RD FLOOR REAR EXTERIOR DOOR WINDOW IS NOT FIRE RATED FOR B DOOR

  • Open

    CN105015 — REPAIR DOOR, INT.

    INTERIOR DOORS FRONT 1ST FLOOR AND BASEMENT MISSING IN HALLWAY.INTERIOR DOOR MISSING CLOSER AND DO NOT LATCH THROUGHOUT.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    5306 BASEMENT REAR BIKE ROOM TO HALLWAY HOLES AT TOP OF WALLS

  • Rodent-related

    CN136016 — ROACHES

    APARTMENT 204 ROACH INFESTATION.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    5308 PORCH-JOISTS AND BEAMS OVERSPANNED. COLUMNS OVER NOTCHED STACKED ON BEAMS AND SHIFTING. RAIL SECTIONS SHOW DEFLEXION, WEAK CONNECTIONS AT COLUMNS. TREADS AND RISERS LOOSE. MISSING BOLTED CONNECTIONS, JOIST HANGERS, STEEL BRACKET AT BEAM COLUMN CONNECTION, TIE STRAPS. AREA UNDER PORCH BEING USED AS PARKING AREA VEHICLE IMPACT PROTECTION REQUIRED. 5300-JOISTS SPACED OVER 16 INCHES ON CENTER DECKING ROTTED. NO BOLTED CONNECTIONS. OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE TWO DANGEROUS PORCH SYSTEMS.

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    BOILER ROOM JUNK AND DEBRIS

  • Open

    CN065034 — REPAIR WINDOW SILLS

    WINDOW SILLS-OPEN JOINTS CRACKED.

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    BOILER ROOM JUNK AND DEBRIS[NO ENTRY 4-22-10]

  • Open

    CN031023 — FIRE EXTNGSHR RECHARGE & TAG

    FIRE EXTINGUISHER-TAGS EXPIRED IN 2006.[NO ENTRY 4-22-10]

  • Open

    CN105035 — REPAIR DOOR HARDWARE

    THIRD FLOOR STAIRWELL DOOR MISSING DOOR KNOB[NO ENTRY 4-22-10]

  • Open

    CN107035 — MAINTAIN EXIT SIGN ILLUMINATED

    VARIOUS LOCATIONS EXIT SIGNS INOPERABLE[NO ENTRY 4-22-10]

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    LAUNDRY ROOM-NO SMOKE DETECTOR[NO ENTRY 4-22-10]

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    LAUNDRY ROOM-NO CO2 DETECTOR[NO ENTRY 4-22-10]

  • Open

    PL171027 — LICENSED BONDED PLMBG CONTRCTR

  • Open

    PL171017 — OBTN PERMIT FOR PLUMBING WORK

    PERMIT

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    REINSPECT

  • Open

    PL231060 — TEST ALTERED SYSTEM

    TEST

  • Open

    PL236020 — INSTALL FIXTURES PROPERLY

    ALL

  • Open

    PL157047 — STOP LEAKING WATER

    REPLACE ABOVE DEFECTIVE FAUCETS WATER RUNNING CONSTANTLY AT BOTH FIXTURES

  • Open

    PL156017 — REPLACE DEFECTIVE WATER PIPING

    APARTMENT 301 DEFECTIVE TUB FAUCETS AND LAVATORY FAUCETS IN BATHROOM

  • Open

    CN107035 — MAINTAIN EXIT SIGN ILLUMINATED

    EXIT SIGNS DON'T WORK.

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    SUBMIT PLANS AND PERMITS FOR REPAIRS.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    NORTH WINDOW SILLS CRACKED.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    NORTH 5308 PORCH LOOKOUTS AND UPRIGHTS IMPROPER CONNECTION, NO FOOTING, TREADS SPLIT, NO LEDGER BOLTS NO JOIST HANGING, IMPROPER STRINGER AND LANDING SUPPORT.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    NORTH 5308 PORCH LOOKOUTS AND UPRIGHTS IMPROPER.

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    BOILER ROOM JUNK AND DEBRIS.

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    CENTER HALLWAY AREAWAY STORAGE ITEM.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • building

    Building Violation

  • building

    Building Violation

Timeline

  1. Open City violation record — CN104035 MAINTAIN WINDOW
  2. Open City violation record — CN136016 ROACHES
  3. Open City violation record — CN133016 CARPETING
  4. Open City violation record — NC5042 SELF-CLOSE CLASS B FIRE DOOR
  5. 311 building — Building Violation
  6. 311 building — Building Violation
  7. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  8. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
  9. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  10. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  11. Open City violation record — CN105015 REPAIR DOOR, INT.
  12. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  13. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  14. Open City violation record — CN107015 ILLUMINATE PUBLIC STAIR/HALL
  15. Open City violation record — CN197088 CARB MONOX DETECT IN HOTEL
  16. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  17. Open City violation record — CN065034 REPAIR WINDOW SILLS
  18. Open City violation record — CN064014 REPAIR CORNICE
  19. Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
  20. Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
  21. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  22. Open City violation record — CN078014 ILLUMINATE EXIT AREAS
  23. Open City violation record — CN136016 ROACHES
  24. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  25. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  26. Open City violation record — CN107035 MAINTAIN EXIT SIGN ILLUMINATED
  27. Open City violation record — CN105035 REPAIR DOOR HARDWARE
  28. Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
  29. Open City violation record — CN138056 DEBRIS, EXCESSIVE
  30. Open City violation record — CN065034 REPAIR WINDOW SILLS
  31. Open City violation record — CN138056 DEBRIS, EXCESSIVE
  32. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  33. Open City violation record — PL156017 REPLACE DEFECTIVE WATER PIPING
  34. Open City violation record — PL157047 STOP LEAKING WATER
  35. Open City violation record — PL236020 INSTALL FIXTURES PROPERLY
  36. Open City violation record — PL231060 TEST ALTERED SYSTEM
  37. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  38. Open City violation record — PL171017 OBTN PERMIT FOR PLUMBING WORK
  39. Open City violation record — PL171027 LICENSED BONDED PLMBG CONTRCTR
  40. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY

Recently closed / other violations (sample)

  • Closed / other

    CN065034 REPAIR WINDOW SILLS

  • Closed / other

    CN064014 REPAIR CORNICE

  • Closed / other

    CN101015 REPAIR INTERIOR WALLS/CEILING

  • Closed / other

    CN105015 REPAIR DOOR, INT.

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN107015 ILLUMINATE PUBLIC STAIR/HALL

  • Closed / other

    CN104015 REPLCE WINDOW PANES, PLEXGLAS

  • Closed / other

    CN065034 REPAIR WINDOW SILLS

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN107035 MAINTAIN EXIT SIGN ILLUMINATED

  • Closed / other

    CN031023 FIRE EXTNGSHR RECHARGE & TAG

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN105035 REPAIR DOOR HARDWARE

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    EL0023 INSTALL COVERS

  • Closed / other

    EL0027 RESTORE EXIT AND EM

  • Closed / other

    EL0016 ADD RECEPTACLES

  • Closed / other

    EL0019 DEFECTIVE FIXTURES

  • Closed / other

    EL0084 SEE INSPECTOR COMMENTS

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    NC2011 PLANS & PERMITS REQ - CONTRCTR

  • Closed / other

    CN107035 MAINTAIN EXIT SIGN ILLUMINATED

  • Closed / other

    CN107025 INSTALL EXIT SIGN

Around 5300 S Hyde Park Blvd

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:30 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com