Free building report

530 W ALDINE AVE

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 530 W Aldine Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

15Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
1311 building (24 mo)

What rat complaints mean →

All open City violation records (15)

2 of 15 open City violation records are from the last 24 months (since November 2024), shown newest first. 13 older ones are collapsed below — still open, still counted.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    PROVIDE PROOF OF COMPLIANCE WITH SAFETY BULKHEAD MANDATE (DOUBLE WALLED CYLINDER) OR OBTAIN PERMIT TO REPLACE.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    PROVIDE PROOF OF COMPLIANCE WITH SAFETY BULKHEAD MANDATE (DOUBLE WALLED CYLINDER) OR OBTAIN PERMIT TO REPLACE.

Show 13 older open City violation records (before November 2024)
  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    PROOF OF DOUBLE WALLED CYL.

  • Open

    CN062034 — REPAIR COPING

    FRONT ELEVATION /COPING - SHIFTED STONE SECTIONS WITH OPEN MORTAR JOINTS.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    FRONT ELEVATION /STONE SILLS - OPEN MORTAR JOINTS THROUGHOUT.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    FRONT ELEVATION /EXTERIOR WALL - MASONRY DEFLECTIONS NEAR WINDOW LOCATIONS; SHIFTED BRICK SECTIONS WITH OPEN MORTAR JOINTS AT MULTIPLE LOCATIONS; WASHED OUT MORTAR AT VARIOUS LOCATIONS. PERMIT REQUIRED FOR MASONRY REPAIRS. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    PROOF OF DOUBLE WALLED CYL.

  • Open

    CN031023 — FIRE EXTNGSHR RECHARGE & TAG

    FIRE EXSTINGUISHERS TAGS EXPIRED - 2015.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING /MOST APTS. - NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS.

  • Open

    CN197079 — REPAIR/REPLACE SMOKE DETECTORS

    3RD FLOOR CORRIDOR - SMOKE DETECTOR - LOOSE AND HANGING.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    CAT-1 TEST

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEVATION, 5TH FLOOR - EXTERIOR WALL - FRACTURES AND SHIFTING BRICK ABOVE WINDOWS.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    SOUTH ELEVATION, MULTIPLE FLOORS - STONE SILLS - OPEN MORTAR JOINTS.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING - NO RESPONSE, SIDE GATE LOCKED- UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF EXPIRED FIRE EXTINGUISHER TAGS.

  • Open

    CN062024 — PARAPET

    WEST ELEVATION, PARAPET - WASHED OUT MORTAR.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

  • building

    Building Violation

Timeline

  1. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  2. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  3. 311 building — Building Violation
  4. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  5. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  6. Open City violation record — CN065034 REPAIR WINDOW SILLS
  7. Open City violation record — CN062034 REPAIR COPING
  8. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  9. Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
  10. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  11. Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
  12. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  13. Open City violation record — CN062024 PARAPET
  14. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  15. Open City violation record — CN065034 REPAIR WINDOW SILLS
  16. Open City violation record — CN061014 REPAIR EXTERIOR WALL

Recently closed / other violations (sample)

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN197079 REPAIR/REPLACE SMOKE DETECTORS

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV1111 MAINTAIN OR REPAIR HYDRO ELEVA

  • Closed / other

    EV0065 TEST G & S PASS ELE

Around 530 W Aldine Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:19 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address