Free building report
5235 S DREXEL AVE
Winter habitability score Many open City violation records and/or complaint activity
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 5235 S Drexel Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (43)
3 of 43 open City violation records are from the last 24 months (since November 2024), shown newest first. 40 older ones are collapsed below — still open, still counted.
- Open
CN070014 — REPAIR EXTERIOR STAIR
EAST ELEVATION / EXTERIOR BASEMENT STAIRS - LARGE HOLE IN CONCRETE AT DOOR. 14X-3-303.11.
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
SOUTH ELEVATION / WINDOW PANE - CRACKED AT GRADE. 14X-3-303.13.
- Open
CN104035 — MAINTAIN WINDOW
NORTH ELEVATION / WOOD WINDOW FRAME - ROTTING WITH FLAKY PAINT AT 1ST FLOOR. 14X-3-303.13.
Show 40 older open City violation records (before November 2024)
- Open
CN073024 — REPAIR EXTERIOR DOOR FRAME
EAST/REAR ENTRY DOOR FRAMES/ALL LEVELS - PAINT PEELING
- Open
CN108015 — REPAIR SKYLIGHT
#5239/3RD FLOOR/INTERIOR STAIRWELL - GLASS PANE MISSING; BOARDED FROM WITHIN
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO INSPECT ALL INTERIORS, APARTMENTS, STAIRWELLS, AND BASEMENT. UNVERIFED DETECTORS AND CONDITIONS.
- Open
CN061014 — REPAIR EXTERIOR WALL
EAST/EXTERIOR WALL - WASHED OUT MORTAR
- Open
CN104055 — REPUTTY WINDOW PANES
EAST COURTYARD/ALL LEVELS/WINDOW TRIM - ROTTING; PAINT PEELING
- Open
CN197087 — CARB MONOX DETECT IN RESID
BASEMANT 906 NO CARBON MONOXIDE.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
BUILDING OWNER ID NOT COMPLETE.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE UNVERIFIED DETECTORS AND CONDITIONS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
ALL APARTTMENTS AND INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF INTERCOM SYSTEM AND HALL LIGHTS NOT WORKING. UNABLE TO I9NSPECT INTERIOR STAIRWAYS, REAR PORCHES, NORTH EXTERIOR ELEVATION AND SOME POTIONS OF EAST EXTERIOR ELEVATION. UNABLE TO VERIFY COMPLIANCE ON PREVIOUS PORCH VIOLATIONS. UNABLE TO COMPLETE INTERIOR INSPECTION (OVERALL CONDITIONS) FOR 2016 ANNUAL INSPECTION.
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
EAST ELEVATION/ REAR METAL GATE 80 INCHES HIGH AND METAL OVERHEAD ROLL UP GATE 9 FEET HIGH - CONSTRUCTED WITHOUT OBTAINING A PERMIT.
- Open
CN064014 — REPAIR CORNICE
SOUTH ELEVATION CORNICE HAS WASHED OUT MORTAR JOINTS.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED FROM 2009 THRU 2014.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO 5239 TO VERIFY COMPLAINT OF MICE INFESTATION.UNABLE TO GAIN ENTRY TO VERIFY EXISTING VIOLATIONS.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS,PORCHES AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION.
- Open
CN062034 — REPAIR COPING
COPING TILE - MISSING
- Open
CN138106 — STOP/REMOVE NUISANCE
APPLIANCES, MATERIALS STORED IN REAR YARD.
- Open
CN198019 — FILE BLDG REGISTRATION
NOT REGISTERED 2009-2011
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY.
- Open
CN062034 — REPAIR COPING
COPING TILE - MISSING
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY.
- Rodent-related
CN135016 — MICE/RODENTS
EXTERMINATE FOR RODENTS
- Open
CN103015 — REPAIR FLOOR
ROTTED SUB FLOOR WATER DAMAGED LARGE HOLES
- Open
PL165017 — REPL DEFECTIVE BATHROOM FLOOR
MISSING FLOOR TILES KITCHEN AND BATH 5245 BASEMENT
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE ALL PORCH SYSTEMS
- Open
CN101025 — INT WALL/CEILING CHIP PLASTER
CEILING COLLAPSED WATER DAMAGED BATHROOM 5245 BASEMENT
- Open
CN197019 — INSTALL SMOKE DETECTORS
NO SMOKE DETECTOR 5245 BASEMENT
- Open
CN073044 — REPAIR EXTERIOR DOOR HARDWARE
EXTERIOR DOOR HARDWARE INOPERABLE 5245 FRONT
- Open
CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU
BASEMENT APARTMENT 5245 SUSPENDED CEILING EXPOSED JOISTS
- Open
EL0029 — EXPOSED WIRING
EXPOSED WIRES KITCHEN 5245 BASEMENT APARTMENT
- Open
CN108015 — REPAIR SKYLIGHT
5245 LEAKING SKYLIGHT CAUSING WATER DAMAGE
- Open
CN070024 — REPAIR PORCH SYSTEM
(1535-45) GUARDRAILS LOOSE, DESIGNED WITH HORIZONTAL COMPONENTS, NO VIVIBLE FOOTINGS TREADS CRACKED AND LOOSE COLUMNS TWISTED AND BOWED NO BOLTED CONNECTIONS BEAMS AND JOIST UNDERSIZED
- Open
PL157047 — STOP LEAKING WATER
STOP WATER LEAKING INTO BATHROOM 5245 BASEMENT
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCHES HORIZONTAL HANDRAILS ALL PORCHES ALL FLOORS 5235-37-39-41 AND 906-08 ALL HAVE COLUMN ON TOP OF BEAM CONSTRUCTION AT 5245 THE COLUMN SPLICES ARE NOT ROTTED ALL HAVE 4X4 COLUMNS OVER 24 ALL COLUMNS ARE NOT BRACKETED TO FOOTINGS NO HANDRAILS OR GUARDS AT BASEMENT OR PASSAGEWAY STEPS TREADS UNDERSIZED AT 9 1/4 INCHES
- Open
CN140046 — PIGEONS-NESTING
BIRDS FOULING 3RD FLOOR 5235
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
SERVICE WALK AT EAST OF 906-08 POCKMARKED DEEPLY UNEVEN
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY TO COMMON AREA OR 5245 2ND FLOOR
- Open
CN070024 — REPAIR PORCH SYSTEM
RAER PORCH 5235-37 IMPROPER PICKET, NO LEDGER BOLTS , REPLACE 4X4 WITH 6X6 , RAILS LOOSE , IMPROPERLY BUILTTREADS SPLIT 5239 PORCH STRINGER SCAB WORK NO FOOTING, IMPROPER PICKETS, UPRIGHT IMPROPERLY JOINT AND OUT OF PLUMB , TREADS WOOD SPLIT, 5245 PORCH IMPROPERLY PICKET , NO FOOTING NO LEDGER BOLTS LOOKOUTS NOT SEALED IN WALL , UPRIGHT IMPROPER JOINT.
- Open
CN062024 — PARAPET
EAST PARAPET WALL LOOSE BRICKS AND MORTAR MISSING PORCH AREA WALL MORTAR MISSING 5239 WALL BRICKS MISSING , EAST WALL MORTAR MISSING .
- Heat-related
CN132016 — HEAT UNIT ADEQUATELY
INSUFFICIENT HEAT IN UNIT 5235-1-63 DEGREES 5237-1-63 DEGREES 3-60 DEGREES
- Heat-related
CN046013 — UNAPPROVED HEATING DEVICE
IMPROPER HEATING DEVICE STOVES AND SPACE HEATERS ALL UNITS INSP
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
- building
Buildings - Plumbing Violation
- building
Buildings - Plumbing Violation
- building
Buildings - Plumbing Violation
- building
Buildings - Plumbing Violation
Timeline
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- 311 building — Building Violation
- 311 building — Buildings - Plumbing Violation
- 311 building — Buildings - Plumbing Violation
- 311 building — Buildings - Plumbing Violation
- 311 building — Buildings - Plumbing Violation
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN108015 REPAIR SKYLIGHT
- Open City violation record — CN073024 REPAIR EXTERIOR DOOR FRAME
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN064014 REPAIR CORNICE
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — PL157047 STOP LEAKING WATER
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN108015 REPAIR SKYLIGHT
- Open City violation record — EL0029 EXPOSED WIRING
- Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN101025 INT WALL/CEILING CHIP PLASTER
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — PL165017 REPL DEFECTIVE BATHROOM FLOOR
- Open City violation record — CN103015 REPAIR FLOOR
- Open City violation record — CN135016 MICE/RODENTS
Recently closed / other violations (sample)
- Closed / other
CN134026 RAT STOP AROUND EXTERIOR
- Closed / other
CN140046 PIGEONS-NESTING
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN138106 STOP/REMOVE NUISANCE
- Closed / other
CN131026 REPAIR SCREENS
- Closed / other
CN070014 REPAIR EXTERIOR STAIR
- Closed / other
CN106015 REPAIR INTERIOR STAIR SYSTEM
- Closed / other
CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Closed / other
CN070014 REPAIR EXTERIOR STAIR
- Closed / other
NC2021 PERMIT REQUIRED - CONTRACTOR
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN064014 REPAIR CORNICE
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN062034 REPAIR COPING
- Closed / other
CN015012 NO KEY TO USE EXIT DOOR
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN062024 PARAPET
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
NC2021 PERMIT REQUIRED - CONTRACTOR
Around 5235 S Drexel Ave
- Hyde Park building violations and 311 complaints
- UChicago off-campus housing: Hyde Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:05 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.