Free building report
5225 S Blackstone Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 5225 S Blackstone Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (12)
12 of 12 open City violation records are from the last 24 months (since November 2024), shown newest first.
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
BASEMENT AND 3RD FLOOR CEILINGS CRACED WITH HOLES. ALL HALWAYS AND STAIRWAY HAS CRACKED PLASTER WITH CHIPPED AND LOOSE PAINT. 14X-3-304.3
- Open
CN197019 — INSTALL SMOKE DETECTORS
BUILDING THROUGHOUT HAS MISSING SMOKE DETECTORS. 14X-5-504.8
- Open
CN197087 — CARB MONOX DETECT IN RESID
APT 1 AND BASEMENT HAS MISSING CARBON MONOXIDE DETECTORS AT TIME OF INSPECTION. 14-5-504.9
- Open
CN070024 — REPAIR PORCH SYSTEM
EAST ELEVATION / 3 STORY WOOD PORCH / COLUMNS HAVE BEEN INSTALLED WITHOUT METAL BASES. SOME COLUMNS ARE STACKED UPON ANOTHER AND ARE FASTEND WITH LIGHT GUAGE METAL GUSSETS. COLUMN HALF LAP JOINTS MEASURE ONLY 6 INCHES LONG AND HAVE ONLY 2 UNDERSIZED ANCHOR BOLTS AND METAL GUSSETS AT HALF LAP JOINTS. STAIR LANDING IS CANTILEEVERED PASSED COLUMNS UP TO 3 FEET AND ARE SUPPORTED BY A SINGLE 2X12 BEAM. ALL RAILINGS ARE OVERSPANNED, UNDERSIZED AND FASTENED WITH NAILS ONLY. STAIRS HAVE LARGE GAPS AT BOTTOM OF RAILINGS UP TO 12 INCHES WIDE. ENTIRE STAIR SYSTEM HAS MULTIPLE MAKESHIFT BRACES ADDED TO LIMIT THE SWAY OF THE POORLY BUILT STAIR SYSTEM. PLANS AND PERMIT ARE REQUIRED TO REPLACE THE REAR 3 STORY WOOD PORCH. SUBJECT TO FIELD INSEPCTION AND APPROVAL. 14X-3-303.11
- Open
NC2071 — WORK NOT ALLOWED
3 UNIT BUILDING HAS BEEN CONVERTED INTO SINGLE ROOM OCCUPANCY TYPE BUILDING WITH UP TO 19 TENANTS RENTING BEDROOMS OUT THROUGHOUT 1ST THROUGH 3RD FLOORS. EACH FLOOR HAS UP TO 6 BEDROOMS. 14A-4-402.3
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
3 UNIT BUILDING HAS BEEN CONVERTED INTO SINGLE ROOM OCCUPANCY WITH UP TO 19 PEOPLE RENTING ROOMS ON 1ST THROUGH 3RD FLOORS. SUBMIT PLANS AND OBTAIN PERMIT TO AUTORIZE ALTERATIONS AND CHANGE OF USE TO 3 DWELLING UNIT BUILDING. 14A-4-401.1
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
REAR PORCH AT 1ST THROUGH 3RD FLOORS HAVE TABLES AND CHAIRS SET UP BLOCKING EGRESS ( DANGEROUS AND HAZARDOUS ). LARGE FLOWER POTS ARE BEING STORED AT REAR STAIR LANDING AT IME OF INSPECTION. 14X-5-505.1.2
- Open
CN138106 — STOP/REMOVE NUISANCE
REAR PORCH DECKS ARE BEING USED FOR CONGREGATION BY MULTIPLE TENANTS AT 3 DWEILLING UNIT BUILDING, DANGEROUS AND HAZARDOUS. TABLES, CHAIRS, PARTY LIGHTS AND HOUSEHOLD ITEMS ARE BEING STORED AT TIME OF INSEPCTION. REAR YARD HAS NUMEROUS OVERGROWN TREES. 14X-1-103
- Open
CN070014 — REPAIR EXTERIOR STAIR
WEST ELEVATION FROM GRADE TO BASEMENT / STAIRS ARE MISSING GUARDRAIL AND HANDRAIL. 14X-3-303.11
- Open
CN194019 — REPAIR OR REPLACE
PER SECTION CODE : 14X-7-703.2 / APT 3 AT KITCHEN / SWITCH IS MISSING COVER PLATE.
- Open
PL157047 — STOP LEAKING WATER
KITCHENS AT 1ST AND 3RD FLOORS HAVE LEAKING WATER. ONE SINK HAS A BUCKET UNDERNEATH TO CATCH LEAKING WATER. 14X-9-904.1
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
FRONT ENTRY SERVICE WALK HAS CRACKED AND MISSING SLATE (TRIPPING HAZARD).
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
- building
Building Violation
Timeline
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — PL157047 STOP LEAKING WATER
- Open City violation record — CN194019 REPAIR OR REPLACE
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- 311 building — Building Violation
- 311 building — Building Violation
Recently closed / other violations (sample)
No recent closed violations in the sample.
Around 5225 S Blackstone Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:23 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.