Free building report
5205 S DREXEL AVE
Winter habitability score Many open City violation records and/or complaint activity
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 5205 S Drexel Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (32)
16 of 32 open City violation records are from the last 24 months (since November 2024), shown newest first. 16 older ones are collapsed below — still open, still counted.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO INSPECT ALL INTERIORS, STAIRWELLS, COMMON AREAS, BASEMENT, REAR PREMISES, AND REAR PORCHES. UNVERIFIED DETECTORS AND CONDITIONS. (14A-1-104.7)
- Open
CN105035 — REPAIR DOOR HARDWARE
#5205/GRADE/VESTIBULE DOOR - LOCK MISSING (14X-3-304.6)
- Open
CN105015 — REPAIR DOOR, INT.
#5205/GRADE/VESTIBULE DOOR - RUBBING AGAINST FLOOR; DIFFICULT TO OPEN (14X-3-304.6)
- Open
CN197019 — INSTALL SMOKE DETECTORS
#5205/INTERIOR STAIRWELL/3RD FLOOR/SMOKE DETECTOR - MISSING (14X-5-504.8)
- Open
CN104065 — REPAIR WINDOW HARDWARE
UNIT 5205-N1A/BEDROOM/WINDOW - LOCKS NOT WORKING AT TIME OF INSPECTION; CAN BE ACCESSED/OPENED FROM EXTERIOR - UNSECURED (14X-3-303.15)
- Open
CN073014 — REPAIR EXTERIOR DOOR
UNIT 5205-N1A/REAR ENTRY DOOR - DIFFICULT TO OPEN (14X-3-303.17)
- Open
CN073044 — REPAIR EXTERIOR DOOR HARDWARE
UNIT 5205-N1A/REAR ENTRY DOOR/BEDROOM - DOOR KNOB/HANDLE MISSING (14X-3-303.17)
- Rodent-related
CN134036 — RAT PROOF OPENINGS
UNIT #5205-N1A/KITCHEN - GAPS IN FLOOR UNDERNEATH BASEBOARD (BEHIND REFRIGERATOR); GAPS IN WALLS AROUND PLUMBING PIPES;MECHANICAL CLOSET - HOLES IN WALL NEAR OUTLETS; DRYWALL/PLASTER MISSING AT CEILING (14X-3-303.6)
- Rodent-related
CN134016 — RATS
UNIT #5205-N1A - RATS THROUGHOUT UNIT (14X-3-308)
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
UNIT #5205-N1A/BATHROOM, HALLWAY - WALLS ARE PUCKERING FROM WATER LEAKING DOWN WALLS;KITCHEN- GAPS IN WALLS AROUND PLUMBING PIPES;MECHANICAL CLOSET - HOLES IN WALL NEAR OUTLETS; DRYWALL/PLASTER MISSING AT CEILING (14X-3-304.3)
- Open
NC3052 — EXIT THROUGH BEDROOM/BATHROOM
UNIT 5205-N1A - ONE BEDROOM CONDO UNIT; REAR EXIT IS THROUGH BEDROOM. (14B-10-1016.2)
- Open
CN031023 — FIRE EXTNGSHR RECHARGE & TAG
#5205 VESTIBULE (GRADE)/FIRE EXTINGUISHER - MAINTENANCE TAG MISSING (14X-5-504.5)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF LOW BATTERY IN SMOKE DETECTORS. 14A-1-104.7.
- Open
CN131026 — REPAIR SCREENS
WEST ELEVATION & COURTYARD / SCREENS - MISSING AND TORN AT MULTIPLE LOCATIONS. 14X-3-303.16.
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
SOUTH ELEVATION / SERVICE WALK - CRACKING & CRUMBLING AT WEST GATE. 14X-3-302.4.
- Open
PL170017 — PRV FLOOR DRAIN WITH METAL STR
SOUTH ELEVATION / METAL STRAINER - MISSING AT DRAIN AT LOCKED WEST GATE. 18-29-402.5.
Show 16 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO GAIN INTERIOR ACCESS TO CONDUCT ANNUAL INSPECTION.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED FROM 2005 THRU 2015.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2015 ANNUAL INSPECTION.
- Open
CN070024 — REPAIR PORCH SYSTEM
EAST 3 STORY PORCH, ENCLOSED SECTIONS ; COLUMNS ARE ERECTED ON TOP OF CONCRETE SLAB; FOUNDATION STATUS UNKNOWN.UNDERSIZED 6"X6" BEAMS SPAN 7'-6" AND ARE FASTENED TO COLUMNS WITH NAILS ONLY.UNDERSIZED 2"X8" DECK JOISTS SPAN 13'-4".PLANS AND PERMIT ARE REQUIRED TO REPAIR REAR PORCH ENCLOSED SECTIONS.
- Open
CN070024 — REPAIR PORCH SYSTEM
EAST 3 STORY PORCH, ENCLOSED SECTIONS ; COLUMNS ARE ERECTED ON TOP OF CONCRETE SLAB; FOUNDATION STATUS UNKNOWN.UNDERSIZED 6"X6" BEAMS SPAN 7'-6" AND ARE FASTENED TO COLUMNS WITH NAILS ONLY.UNDERSIZED 2"X8" DECK JOISTS SPAN 13'-4".PLANS AND PERMIT ARE REQUIRED TO REPAIR REAR PORCH ENCLOSED SECTIONS.
- Open
CN065014 — REPAIR LINTELS
WEST ELEVATION 2ND AND 3RD FLOOR WINDOW LINTELS - RUSTED AND SAGGING.PLANS AND PERMIT ARE REQUIRED TO REPLACE LINTELS.
- Open
NC2031 — NO PLANS/PERMIT AT JOBSITE
REAR EXTERIOR PORCH GRADE TO 3RD FLOOR,NO PLANS OR PERMIT ON SITE.PERMIT # 100462300 ISSUED 03/27/2013.
- Open
NC2053 — COMPLETE WORK
EAST ELEVATION,REAR EXTERIOR PORCH,GRADE TO 3RD FLOOR,WORK STOPED,NO WORKERS ON SITE.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
EAST GATES ARE LOCKED-UNVERIFIED CONDITION OF THE PORCHES. BUILDING INTERIOR-NO RESPONSE AT LOCKED FRONT GATE (DOORBELL / INTERCOM SYSTEM); UNVERIFIED DETECTORS AND COMPLAINT OF: SR#114146253-(APT.N3A) NO WATER / NO HEAT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH-SOME 6X6 COLUMN SPLICES ARE TWISTED; NOTICEABLE GAPS. DOUBLE 2X10 BEAM AT GRADE, SUPPORTING THE 1ST FLOOR AND ABUTTING THE 6X6 COLUMNS THAT SUPPORT THE ENCLOSED SECTIONS, ARE ONLY SET ON TOP OF 2X6 MEMBERS THAT ARE ONLY NAILED INTO THE COLUMNS; NORTH END OF THE BEAM WITH A NOTICEABLE 1/2 INCH GAP. MID-LANDING FLIGHTS SHIFT LATERALLY UPON LOAD. STRINGERS ARE ONLY NAILED INTO THE HEADER BEAMS; SOME SEPERATION AT THE CONNECTIONS. OBTAIN PERMIT FOR REPAIRS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING, REAR ENCLOSED PORCH AND NORTH AND SOUTH EXTERIOR PORCHES - NO ENTRY, NO RESPONSE.
- Open
CN198019 — FILE BLDG REGISTRATION
NOT REGISTERED 1990-2009
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
NOT POSTED.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH G TO 1ST UPRIGHT OUT OF PLUMB, NO FOOTING AND ROTTED WOOD, LOOKOUTS ROTTED.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
SUBMIT PLANS AND PERMITS FOR REPAIRS.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Buildings - Plumbing Violation
- rodent
Rodent Baiting/Rat Complaint
- building
Building Violation
- building
Building Violation
- building
Building Violation
- building
Building Violation
- building
Building Violation
- building
Building Violation
Timeline
- Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Open City violation record — NC3052 EXIT THROUGH BEDROOM/BATHROOM
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN134016 RATS
- Open City violation record — CN134036 RAT PROOF OPENINGS
- Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
- Open City violation record — CN073014 REPAIR EXTERIOR DOOR
- Open City violation record — CN104065 REPAIR WINDOW HARDWARE
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN105015 REPAIR DOOR, INT.
- Open City violation record — CN105035 REPAIR DOOR HARDWARE
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- 311 building — Building Violation
- 311 building — Building Violation
- 311 rodent — Rodent Baiting/Rat Complaint
- 311 building — Buildings - Plumbing Violation
- Open City violation record — PL170017 PRV FLOOR DRAIN WITH METAL STR
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — CN131026 REPAIR SCREENS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- 311 building — Building Violation
- 311 building — Building Violation
- 311 building — Building Violation
- 311 building — Building Violation
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — NC2053 COMPLETE WORK
- Open City violation record — NC2031 NO PLANS/PERMIT AT JOBSITE
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
Recently closed / other violations (sample)
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN061074 PROTECT SIDEWALK DURING CONST
- Closed / other
CN061074 PROTECT SIDEWALK DURING CONST
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN194039 REMOVE
- Closed / other
CN190029 ARRANGE FOR REINSPECTION REGAR
- Closed / other
CN194039 REMOVE
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN131016 SCREEN OUTER DOORS, WINDOWS
- Closed / other
CN077014 REPAIR FENCE
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
EL0022 EXPOSED WIRING FIXTURES
- Closed / other
CN139016 ABANDONED REFRIGERATOR
- Closed / other
CN070024 REPAIR PORCH SYSTEM
Around 5205 S Drexel Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:59 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.