Free building report

501 W Deming Pl

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 501 W Deming Pl, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

19Open City violation records
2Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (19)

2 of 19 open City violation records are from the last 24 months (since November 2024), shown newest first. 17 older ones are collapsed below — still open, still counted.

  • Open

    CN062024 — PARAPET

    ALL ELEVATIONS / PARAPET WALL - LOOSE, ERODED MORTAR JOINTS. PERMIT IS REQUIRED FOR ALL REPAIRS TO PARAPET WALL. ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL UPON COMPLETION. PER 14X-3-303.6

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY. INTERIOR OF BUILDING, NO ENTRY NO RESPONSE. UNABLE TO VERIFY APARTMENTS, INTERIOR STAIR SYSTEMS, SMOKE OR CARBON MONOXIDE ALARMS.

Show 17 older open City violation records (before November 2024)
  • Open

    CN062024 — PARAPET

    3 STORY MASONRY MULTI UNIT BUILDINGALL ELEVATIONS / 501-519 W DEMING PL PARAPET WALLS - LOOSE, EROED MORTAR JOINTS WITH FRACTURES IN VARIOUS LOCATIONS. PERMIT IS REQUIRED FOR ALL PARAPET WALLS. ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL UPON COMPLETION.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    ARRANGE FOR REINSPECTION - UNABLE TO GAIN ENTRY TO VERIFY INTERIOR CONDITIONS

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    ALL ELEVATIONS / 501- 511 / GRADE TO 3RD FLOOR /EXTERIOR WALL - LOOSE,EROED MORTAR JOINTS, WITH FRACTURES IN VARIOUS LOCATIONS THROUGHOUT. PERMIT IS REQUIRED FOR ALL REPAIRS TO EXTERIOR WALL. ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL UPON COMPLETION.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    EAST ELEVATION, EXTERIOR WALL 2ND AND 3RD FLOORS - FRACTURES IN BRICK. SOUTH ELEVATION, EXTERIOR WALL AT SOUTHEAST CORNER OF BUILDING STONEWORK WASHED OUT MORTAR JOINTS. NORTH ELEVATION, 511 W. / 2ND FLOOR - FRACTURE IN BRICK NEAR STEEL BALCONLY CONNECTION. NORTH ELEVATION, EXTERIOR WALL AT 1ST FLOOR - FRACTURES IN BRICK. WEST ELEVATION, BASEMENT EXTERIOR WALL - WASHED OUT MORTAR.

  • Open

    CN065014 — REPAIR LINTELS

    EAST ELEVATION, 3RD FLOOR LINTELS - SEVERELY RUSTED WITH VOLUMETRIC EXPANSION. 2ND FLOOR LINTELS RUSTED. NORTH ELEVATION, MULTIPLE COURTYARD AREAS - 1ST FLOOR LINTELS RUSTED AND SAGGING.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    NORTH ELEVATION, MULTIPLE COURTYARD AREAS - OPEN SILL JOINTS.

  • Open

    CN064014 — REPAIR CORNICE

    EAST ELEVATION, CORNICE - OPEN MORTAR JOINTS. NORTH ELEVATION, COURTYARD AT 501-07 W. - OPEN MORTAR JOINTS.

  • Open

    CN061074 — PROTECT SIDEWALK DURING CONST

    EAST ELEVATION, PROVIDE HEAVY DUTY SIDEWALK CANOPY TO PROTECT SIDEWALK RIGHT OF WAY.

  • Open

    CN062014 — PARAPET & COPING

    WEST AND EAST ELEVATION, COPING - OPEN MORTAR JOINTS. WEST , NORTH AND EAST ELEVATIONS, PARAPET WASHED OUT MORTAR WITH SOME FRACTURES.NORTHEAST CORNER OF BUILDING - PARAPET SEVERELY WASHED OUT MORTAR WITH SHIFTING BRICK OVER PUBLIC WAY - DANGEROUS AND HAZARDOUS. NORTH ELEVATION, COURTYARD AT 501-07 W. - PARAPET WASHED OUT MORTAR WITH SOME LOOSE BRICK. NORTHWEST CORNER OF BUILDING - PARAPET WASHED OUT MORTAR.

  • Open

    BR1001 — OWNER OR LICENSED CONTRACTOR

  • Open

    BR3055 — REPLACE

    REPLACE LEAKING PIPING ON MCDONALD MILLER-LOW WATER CUT OFF-FEED WATER PIPING, AND BLOW DOWN PIPING ON BOILER.

  • Open

    CN138106 — STOP/REMOVE NUISANCE

    FRONT EXTERIOR DOOR AT 2510 GRAFFITI

  • Heat-related

    CN011012 — HEATING PLANT/BOILER ROOM DOOR

    BOILER ROOM DOOR WITHOUT SELF -CLOSING.

  • Open

    CN192019 — NOTIFY DOB, USE OF VACANT LND

    VACANT COMMERCIAL SPACE -CLARK STREET.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    ARRANGE FOR FULL INTERIOR INSPECTION.

  • Heat-related

    CN010022 — 1-HR HEATING PLANT SEPARATION

    BOILER ROOM WITH OPEN CEILING.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    PORCH TO 5119 WITHOUT JOIST HANGERS : STRINGERS ARE NOT BOLTED TO MASONARY WALL : LEDGER NOT BOLTED TO WALL OBTAIN PERMIT FOR PORCH SOUTH PORCH WITH MISSING PICKETS.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  2. Open City violation record — CN062024 PARAPET
  3. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  4. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  5. Open City violation record — CN062024 PARAPET
  6. Open City violation record — CN062014 PARAPET & COPING
  7. Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
  8. Open City violation record — CN064014 REPAIR CORNICE
  9. Open City violation record — CN065034 REPAIR WINDOW SILLS
  10. Open City violation record — CN065014 REPAIR LINTELS
  11. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  12. Open City violation record — BR3055 REPLACE
  13. Open City violation record — BR1001 OWNER OR LICENSED CONTRACTOR
  14. Open City violation record — CN138106 STOP/REMOVE NUISANCE
  15. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  16. Open heat-related City violation record — CN010022 1-HR HEATING PLANT SEPARATION
  17. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  18. Open City violation record — CN192019 NOTIFY DOB, USE OF VACANT LND
  19. Open heat-related City violation record — CN011012 HEATING PLANT/BOILER ROOM DOOR

Recently closed / other violations (sample)

  • Closed / other

    CN138106 STOP/REMOVE NUISANCE

  • Closed / other

    CN196029 POST OWNER/MANAGERS NAME/#

  • Closed / other

    CN065014 REPAIR LINTELS

  • Closed / other

    CN138016 SCAVENGER SERVICE

Around 501 W Deming Pl

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 11:34 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address