Free building report

442 W WELLINGTON AVE

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 442 W Wellington Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

26Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (26)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from June 28, 2016. All 26 are collapsed below — still open, still counted.

Show 26 older open City violation records (before November 2024)
  • Open

    PL151137 — OPEN

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    REPLACE HOIST ROPES ON CENTER ELEVATOR

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    REINSPECT ROPE GRIPPER .

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PERFROM A FULL FIRE SERVICE TEST AND SMOKE DETECTOR TEST AT THE END OF ELEVATOR MODERNIZATION

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    MAKE ALL HIGH HIGH VOLTAGE WIRING PERMENT

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    ID ELEVATORS AT CAR PANELS AND AT ALL LANDINGS (EAST- LOBBY-WEST)

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED - ALL CARS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    CLEAN ELEVATOR CARTOPS AND MACHINE ROOMS - ALL CARS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    MAINTAIN A CURRENT FIRE SERVICE TEST LOG ON SITE FOR ALL CARS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE CODEDATA TAGS ON CONTROLLERS OR DISCONNECTS - ALL CARS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE MAINTENANCE CONTROL PROGRAM ON SITE FOR ALL ELEVATORS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    PROVIDE ADEQUATE MACHINE ROOM LIGHTING FOR EAST AND WEST ELEVATORS

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    INSTALL "IN CASE OF FIRE" PICTOGRAPHS AT LANDINGS WHERE MISSING

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    INSTALL CANOPY EXHAUST FAN ON CARTOP - EAST ELEVATOR

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    INSTALL MISSING LANDING DOOE SIGHT GUARD - 6TH FLOOR EAST

  • Open

    EV1110 — MAINTAIN OR REPAIR ELECT ELEVA

    REPAIR MALFUNCTIONING CAR POSITION INDICATOR - WEST ELEVATOR

  • Open

    NC3042 — UNINTERRUPTED EXIT AT GRADE

    PROVIDE UNINTERUPTED MEANS OF EGRESS (LOCKED GATE)

  • Open

    IR0057 — REPAIR EX. MET.

    ENGINEER REPORT

  • Open

    IR0055 — PROTECT METAL MEMBERS

    PROTECT METAL MEMERS

  • Open

    IR0015 — USE NEW BOLTS OR RODS

    NEW BOLT OR TRUSS RODS

  • Open

    IR0014 — REMOVE RUST

    REMOVE RUST TREADS

  • Open

    IR0012 — F.E. RAILS

    REPAIR RAILS (C/BAL. W/WT)

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY TO INTERIOR FOR ANNUAL INSPECTION

  • Open

    IR0057 — REPAIR EX. MET.

    ENGINEER REPORT (5 YEARS)

  • Open

    IR0055 — PROTECT METAL MEMBERS

    PROTECT METAL MEMBERS (SCRAPE AND PAINT 3 YEARS)

  • Open

    IR0014 — REMOVE RUST

    REMOVE RUST TREADS

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — PL151137 OPEN
  2. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  3. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  4. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  5. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  6. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  7. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  8. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  9. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  10. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  11. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  12. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  13. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  14. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  15. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  16. Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
  17. Open City violation record — IR0012 F.E. RAILS
  18. Open City violation record — IR0014 REMOVE RUST
  19. Open City violation record — IR0015 USE NEW BOLTS OR RODS
  20. Open City violation record — IR0055 PROTECT METAL MEMBERS
  21. Open City violation record — IR0057 REPAIR EX. MET.
  22. Open City violation record — NC3042 UNINTERRUPTED EXIT AT GRADE
  23. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  24. Open City violation record — IR0014 REMOVE RUST
  25. Open City violation record — IR0055 PROTECT METAL MEMBERS
  26. Open City violation record — IR0057 REPAIR EX. MET.

Recently closed / other violations (sample)

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    CN194039 REMOVE

  • Closed / other

    NC9022 I-A I-B I-C AND II FIRE RESIST

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    CN107015 ILLUMINATE PUBLIC STAIR/HALL

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN010032 2-HR HEATING PLANT ENCLOSURE

  • Closed / other

    NC5042 SELF-CLOSE CLASS B FIRE DOOR

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    NC6042 SELF-CLOSE DOOR >4 STORY RES.

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    EV1110 MAINTAIN OR REPAIR ELECT ELEVA

  • Closed / other

    IR0000 SEND EX. METAL LETTER

  • Closed / other

    CN061000 LIFE SAFETY EVALUATION PLAN

  • Closed / other

    IR0000 SEND EX. METAL LETTER

  • Closed / other

    CN061000 LIFE SAFETY EVALUATION PLAN

Around 442 W Wellington Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:05 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com