Free building report
4362 N Kenmore Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 4362 N Kenmore Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (16)
1 of 16 open City violation records are from the last 24 months (since November 2024), shown newest first. 15 older ones are collapsed below — still open, still counted.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
ARRANGE FOR REINSPECTION. INTERIOR OF BUILDING - NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR OF BUILDING INCLUDING UNITS, REAR PORCH, ROOF. NOT ABLE TO VERIFY COMPLAINT OF OCCUPANCY. PER BUILDING CODE SECTION 14A-1-104.7
Show 15 older open City violation records (before November 2024)
- Open
EL0084 — SEE INSPECTOR COMMENTS
SEE DEFECT NOTICE # 12534
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
EAST ELEVATION BASEMENT WINDOWS - BROKEN GLASS PANES.
- Open
CN062034 — REPAIR COPING
SOUTH ELEVATION - BROKEN AND MISSING COPING TILES.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR 3 STORY WOOD PORCH - WOOD DRY ROTTED THROUGHOUT.6X6 COLUMNS SET ON CONCRETE SLAB OR ON BLOCKS SET ON TOP OF CONCRETE SLAB, FOUNDATION STATUS UNKNOWN.6X6 COLUMNS ARE DOUBLE NOTCHED AT BEAM TO COLUMN CONNECTION AREA AND LAP JOINTS.6X6 COLUMNS ARE DRIED OUT AND SPLITTING THROUGHOUT.LEDGER BEAMS MISSING BOLTS.STRINGERS WRAPPED UNDER HEADER AND NAILED TO JOIST.6X6 BEAMS SPAN 8 FEET.GUARDRAILS UNDER 42 INCHES IN HEIGHT AND MISSING INTERMEDIATE SUPPORTS.PLANS AND PERMIT REQUIRED.
- Open
CN138106 — STOP/REMOVE NUISANCE
REAR PORCH AREA - VENTILATION PIPE FOR NEW FURNACES IS RAN THROUGH DECKING OF REAR PORCH.
- Open
CN065014 — REPAIR LINTELS
NORTH ELEVATION 2ND AND 3RD FLOORS - RUSTED AND DEFLECTING LINTELS, SOME LINTELS OVER 6 FEET IN LENGTH - PLANS AND PERMIT REQUIRED FOR REPAIRS.
- Open
CN061014 — REPAIR EXTERIOR WALL
NORTH ELEVATION - BULGING, SHIFTING BRICKS OVER PUBLIC WALKWAY, MASONRY PERMIT REQUIRED.
- Open
CN060002 — PROVIDE SIDEWALK SHED F/PROTCT
PROVIDE CANOPY FOR PROTECTION OF PUBLIC WALKWAY DURING REPAIRS TO LINTELS.
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
INTERIOR OF BUILDING - REHAB OF ENTIRE BUILDING ON GOING, WORK INCLUDING ALL PLUMBING AND ELECTRICAL WITHOUT OBTAINING PERMITS. AFTER OBTAINING PERMITS OWNER NEED'S TO CONTACT APPROPRIATE BUREAU'S TO INSPECT WORK PRIOR TO ANY WORK PROCEEDING.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
INTERIOR OF BUILDING - NEW FORCED AIR FURNACES AND DUCT WORK INSTALLED WITHOUT FIRST SUBMITTING PLANS AND OBTAINING PERMIT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR 3 STORY PORCH, 6X6 COLUMNS INBEDED IN CONCRETE OR RESTING ON SQUARE CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN. 2X10 HEADERS CONNECTIONS NAILED ONLY. GUARD RAILS CONNECTIONS TO MASONARY WALLS AND COLUMN NAILED ONLY. PLANS AND PERMIT REQUIRED FOR REPAIRS.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING, NO RESPONSE TO VERIFT DETECTORS.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH- SOME HANDRAILS NOT 42" IN HEIGHT, INSUFFICIENT RAILINGS ANCHORS, STACKED COLUMN CONNECTIONS. COLUMN NOTCHES, FIRE CUTS AND BUTT JOINTS IN CLOSE APROXIMITY UNDER 3, LANDINGS WITH 2X8 BEAMS ON NORTH SIDE OF STAIRS- UNDERSIZED. LEDGERS MISSING SOME BOLTS- REQUIRED 16" ON CENTER. JOIST HANGERS AND LEDGER BOLTS MISSING AT WEST END FOR 3. SOUTHWEST COLUMN NOTCHED ON 2SIDES FOR RIME JOIST AND BEAM-OVER NOTCHED, SOME COLUMN OUT OF PLUMB AND TWISTED OTHER COLUMNS ALSO OVER NOTCHED. SOME JOIST SISTERED WITH OUT LEDGER SUPPORT OR MASONRY POCKET SUPPORT. SOUTHWEST COLUMN WITH CONCRETE POURED AROUND COLUMN. OBTAIN PLANS AND PERMIT.
- Open
CN061014 — REPAIR EXTERIOR WALL
EAST ELEVATION FRACTURES, OPEN MORTAR JOINT, OPEN LIMESTONE JOISTS ON MASONRY COLUMNS AND BALCONIES- THESE- THOSE DEFICIENCIES RETURNING AFTER INSUFFICIENT REPAIRS.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH AT 3 WEST END -SECTION RUNNING NORTH AND SOUTH BETWEEN MASONRY WALLS- ROTTING GUARDRAIL, SAME SECTION OF PORCH AT LEVELS 1-3 BOLT LEDGERS TO MASONRY AND INSTALL JOIST HANGERS. NO JOIST HANGERS AT TOP OF STAIRS AT 2 FOR 3RD LEVEL DECK AND MISSING LEDGER TO MASONRY BOLTS, FROM GROUND TO 1 LOOSE HANDRAIL AND IMPROPER PICKET DESIGN, MISSING JOIST HANGERS FOR 1ST FLOOR DECK AT BASEMENT STAIRS MISSING LEDGER TO MASONRY BOLTS, INSUFFICIENT STRINGER TO LANDING AND DECK CONNECTIONS. BROKEN DECK BOARD AT 2 TOWARD WEST END. PERMIT REQUIRED FOR REPAIRS PLANS ARE REQUIRED FOR REPAIRS.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- rodent
Rodent Baiting/Rat Complaint
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — EL0084 SEE INSPECTOR COMMENTS
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN060002 PROVIDE SIDEWALK SHED F/PROTCT
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN138106 STOP/REMOVE NUISANCE
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN062034 REPAIR COPING
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
Recently closed / other violations (sample)
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN198019 FILE BLDG REGISTRATION
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN061014 REPAIR EXTERIOR WALL
Around 4362 N Kenmore Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 6:21 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.