Free building report
4347 N Kenmore Ave
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 4347 N Kenmore Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (32)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from July 21, 2021. All 32 are collapsed below — still open, still counted.
Show 32 older open City violation records (before November 2024)
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
INTERIOR OF BUILDING /NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS.
- Open
CN196019 — NO POSTED ADDRESS
ADDRESS NOT VISIBLE FROM THE STREET.
- Open
CN131026 — REPAIR SCREENS
SOUTH ELEVATION - TORN WINDOW SCREENS.
- Open
CN065014 — REPAIR LINTELS
SOUTH ELEVATION 3RD FLOOR AT WEST END OF PORCHES - RUSTED AND DEFLECTING LINTEL OVER 6 FEET IN LENGTH. MASONRY PERMIT REQUIRED.
- Open
CN070014 — REPAIR EXTERIOR STAIR
NORTH AND SOUTH STAIRS TO BASEMENT - FRACTURED, SPALLED CONCRETE TREADS.
- Open
CN065034 — REPAIR WINDOW SILLS
SOUTH ELEAVTION 2ND FLOOR AT REAR - FRACTURED WINDOW SILL.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING - NOT REGISTERED FOR 2013 AND 2014.
- Open
CN074024 — PROVIDE GUARD RAIL 42 IN HIGH
REAR BASEMENT ENTRY AREA'S NEAR ALLEY - MISSING PORTIONS OF GUARDRAILS.
- Open
CN062024 — PARAPET
NORTH ELEVATION PARAPET - SPALLING BRICKS AND WASHED OUT MORTAR.
- Open
CN070034 — REPLACE D&H PORCH
EAST ELEVATION,REAR PORCHES AS VIEWED FROM ALLEY,4347-49 2ND FLOOR GUARD RAIL MISSING PICKETS,4353-55 ,3RD FLOOR GUARD RAIL MISSING PICKETS WITH ROTTED BOTTOM RAIL, 4359-61 ,1ST FLOOR GUARD RAIL ROTTED BOTTOM RAIL,BEAM AND COLUMN CONNECTIONS ARE SQUARE CUT ,PULLING AWAY FROM POCKET, COLUMNS ARE OVER NOTCHED,PORCHES ARE DANGEROUS AND HAZARDOUS.PLANS AND PERMIT REQUIRED FOR REPAIR OR REPLACEMENT.
- Open
CN066034 — REPAIR BALCONY
WEST ELEVATION,4347-49 BALCONY UNDERSIDE WITH PEELING PAINT.
- Open
CN067024 — REPAIR EAVES
WEST ELEVATION,4353-55,EAVES ROTTED WITH MISSING BOARDS.
- Open
CN138056 — DEBRIS, EXCESSIVE
WEST ELEVATION,FRONT YARD,PLASTIC BAGS STACKED.
- Open
CN065034 — REPAIR WINDOW SILLS
EAST ELEVATION,STONE WINDOW SILLS,OPEN MORTAR JOINTS.
- Open
CN062024 — PARAPET
EAST ELEVATION,PARPET WALL,WASHED OUT MORTAR,SPALLING BRICKS.
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
4359-61,INTERIOR MARBLE STAIRS GRADE TO 1ST FLOOR,CRACKED TREADS WITH PIECES MISSING,RAILINGS AT 2ND FLOOR,MISSING PICKETS.
- Open
CN190029 — ARRANGE FOR REINSPECTION REGAR
BUILDING NO ENTRY FOR ANNUAL INSPECTION AND COMPLAINT OF BED BUGS.
- Open
CN066034 — REPAIR BALCONY
WEST ELEVATION,4347-49 BALCONY UNDERSIDE WITH PEELING PAINT.
- Open
CN065034 — REPAIR WINDOW SILLS
EAST ELEVATION,STONE WINDOW SILLS,OPEN MORTAR JOINTS.
- Open
CN062024 — PARAPET
EAST ELEVATION,PARPET WALL,WASHED OUT MORTAR,SPALLING BRICKS.
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
4359-61,INTERIOR MARBLE STAIRS GRADE TO 1ST FLOOR,CRACKED TREADS WITH PIECES MISSING,RAILINGS AT 2ND FLOOR,MISSING PICKETS.
- Open
CN070024 — REPAIR PORCH SYSTEM
6 EXTERIOR PORCHES WITH THE FOLLOWING DEFECTS,1) ALL 6X6 COLUMNS ERECTED ON TOP OF SERVICE WALK.2) BEAM TO COLUMN CONNECTIONS SQUAIRE CUTS( NO FIRE CUTS).3) BEAMS TO BUILDING IN POCKETS WITH INADEQUATE 1/8 X 1 INCH ANGLE.4) STRINGERS TO BEAM CONNECTIONS NAILED.5) LEDGER BEAMS NAILED CONNECTIONS.6) RIM JOIST SUPPORTED BY WOOD BLOCKS.7) 2X10 JOISTS ARE OVER 11 FT LONG OVER SPAN.8) GUARD RAILS UNDER SIZED 40 INCH IN HIEGHT.9) THREADS ARE 91/4 INCHES .10) RISERS VERY IN HIEGHT, AS LOW AS 6 INCHES.11) SOUTH WEST PORCH STACKED COLUMNS.12) SOUTH WEST PORCH JOIST OVER SPAND 2X10 AT 13FT.13) SOUTH WEST PORCH BEAMS UNDER CUT AND PLACED DIRECTLY ON WINDOW SILLS.14) PLANS AND PERMITS REQUIRED FOR REPAIRS OR REPLACEMENT.
- Open
CN070024 — REPAIR PORCH SYSTEM
6 EXTERIOR PORCHES WITH THE FOLLOWING DEFECTS,1) ALL 6X6 COLUMNS ERECTED ON TOP OF SERVICE WALK.2) BEAM TO COLUMN CONNECTIONS SQUAIRE CUTS( NO FIRE CUTS).3) BEAMS TO BUILDING IN POCKETS WITH INADEQUATE 1/8 X 1 INCH ANGLE.4) STRINGERS TO BEAM CONNECTIONS NAILED.5) LEDGER BEAMS NAILED CONNECTIONS.6) RIM JOIST SUPPORTED BY WOOD BLOCKS.7) 2X10 JOISTS ARE OVER 11 FT LONG OVER SPAN.8) GUARD RAILS UNDER SIZED 40 INCH IN HIEGHT.9) THREADS ARE 91/4 INCHES .10) RISERS VERY IN HIEGHT, AS LOW AS 6 INCHES.11) SOUTH WEST PORCH STACKED COLUMNS.12) SOUTH WEST PORCH JOIST OVER SPAND 2X10 AT 13FT.13) SOUTH WEST PORCH BEAMS UNDER CUT AND PLACED DIRECTLY ON WINDOW SILLS.14) PLANS AND PERMITS REQUIRED FOR REPAIRS OR REPLACEMENT.
- Open
CN065034 — REPAIR WINDOW SILLS
OPEN SILL JOINTS EAST ELEVATION.
- Open
CN062024 — PARAPET
EAST PARAPET WITH SPALLED BRICK & OPEN MORTAR JOINTS. SOUTH EAST CORNER WITH SHIFTING BRICK & OPEN JOINTS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
INCOMPLETE MANAGEMENT I.D. SIGN
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO INTERIOR ACCESS-UNABLE TO ACCESS PORCHES.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO INTERIOR ACCESS-UNABLE TO ACCESS PORCHES.
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
WINDOW: BROKEN PANE IN STAIRWAY, 2ND TO 3RD, 4353
- Open
CN062024 — PARAPET
LOOSE BRICK AND MORTAR AT SOUTHEAST CORNER PARAPET
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCHES: COLUMNS ERECTED ON TOP OF CONCRETE SLABS, WITH NO BASES, FOUNDATION STATUS UNKNOWN, BEAMS ARE CONNECTED TO COLUMNS WITH SQUARE FIRE CUTS, AND WITH BEAM OPPOSITE ENDS SUPPORTED AT BUILDING EXTERIOR WALLS BY INADEQUATE METAL ANGLE BRACKETS; OBTAIN PERMIT TO REPAIR REAR PORCH SYSTEMS; DECK AT 4353, 3RD HAS ROTTING FLOOR BOARDS & PICKETS; VARIOUS LOCATIONS, BEAMS NO BOLTS, ROOF HATCH MISSING; RAIL 40" HIGH, SHOULD BE 42" HIGH
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED 2005.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
Timeline
- 311 building — Building Violation
- Open City violation record — CN196019 NO POSTED ADDRESS
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN131026 REPAIR SCREENS
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN138056 DEBRIS, EXCESSIVE
- Open City violation record — CN067024 REPAIR EAVES
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN065034 REPAIR WINDOW SILLS
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN198019 FILE BLDG REGISTRATION
Recently closed / other violations (sample)
- Closed / other
CN067024 REPAIR EAVES
- Closed / other
CN138056 DEBRIS, EXCESSIVE
- Closed / other
CN070034 REPLACE D&H PORCH
- Closed / other
CN070024 REPAIR PORCH SYSTEM
- Closed / other
CN065014 REPAIR LINTELS
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN065034 REPAIR WINDOW SILLS
- Closed / other
CN062024 PARAPET
- Closed / other
CN196029 POST OWNER/MANAGERS NAME/#
- Closed / other
CN131026 REPAIR SCREENS
- Closed / other
CN138106 STOP/REMOVE NUISANCE
- Closed / other
PL157047 STOP LEAKING WATER
- Closed / other
CN103015 REPAIR FLOOR
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
- Closed / other
CN073014 REPAIR EXTERIOR DOOR
- Closed / other
CN197087 CARB MONOX DETECT IN RESID
- Closed / other
CN102015 INT WALL/CEILING PEELING PAINT
- Closed / other
CN135016 MICE/RODENTS
Around 4347 N Kenmore Ave
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 6:30 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.