Free building report

421 N Wolcott Ave

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 421 N Wolcott Ave, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

12Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (12)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from February 27, 2017. All 12 are collapsed below — still open, still counted.

Show 12 older open City violation records (before November 2024)
  • Open

    CN062024 — PARAPET

    WEST ELEVATION / PARAPET WALL / OUT OF PLUMB AND LEANING INWARDS / MASONRY - SEVERELY SPALLING OVER PUBLIC SIDEWALK. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. DANGEROUS AND HAZARDOUS CONDITIONS.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEVATION / WATER TOWER STRUCTURE - LOOSE AND HANGING SIDING. SOUTH-EAST ELEVATION / EXTERIOR WALL / 2ND FLOOR LEVEL - SEVERE MASONRY CRACK. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.SOUTH ELEVATION / EXTERIOR WALL / MULTIPLE LOCATIONS - WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.

  • Open

    CN103035 — STRUCTURAL MEMBER, PIER BLOCK

    SOUTH ELEVATION / OLD WATER TOWER FRAME MEMBERS - LOOSE AND HANGING OFF EAST ELEVATION. DANGEROUS AND HAZARDOUS CONDITIONS.

  • Open

    CN063014 — CHIMNEY

    EAST ELEVATION / CHIMNEY - WASHED OUT MORTAR. PERMIT ONLY REQUIRED FOR MASONRY REPAIRS.

  • Open

    CN061074 — PROTECT SIDEWALK DURING CONST

    PROVIDE PROTECTIVE CANOPY OVER PUBLIC SIDEWALK. PERMIT ISSUED BY DEPARTMENT OF TRANSPORTATION REQUIRED FOR SUCH INSTALLATION.

  • Open

    EV1111 — MAINTAIN OR REPAIR HYDRO ELEVA

    PULL PERMIT TO PROPERLY REMOVE ELEVATOR'S FROM PREMISE, AND SCHEDULE INSPECTION WITH CITY

  • Open

    EV0066 — TEST G & S FRT ELE

    NORTH TRAC.

  • Open

    199029 — OPEN TYPE VIOLATION

    1. PERFORM ANNUAL PRESSURE RELIEF TEST OF EAST FREIGHT ELEVATOR; SEAL AND TAG VALVE; SUBMIT TEST REPORT TO CITY OF CHICAGO ELEVATOR BUREAU 1005.2A. 2. PROPERLY REPAIR AND MAINTAIN THE NORTH FREIGHT ELEVATOR IN A SAFE OPERATING CONDITION. THE ELEVATOR IS NOT BEING PROPERLY MAINTAINED AND IS CURRENTLY NOT IN OPERATING CONDITION. OR OBTAIN PERMIT TO REMOVE FREIGHT ELEVATOR FROM ACTIVE SERVICE; REMOVE SUSPENSION ROPES; PLACE CAR AND COUNTERWEIGHTS AT REST AT BOTTOM OF HOISTWAY; PERMANENTLY BOARD UP OR BARRICADE HOISTWAY DOORS ON HOISTWAY SIDE; DISCONNECT POWER FEED LINES. (13-196-590, 13-196-630, 18-30-010, ANSI A17.1). 18-30-010, 13-20-120. EV007672

  • Open

    EV0135 — ILLUMINATE CAB FRT

    NORTH TRAC.

  • Open

    EV0131 — REP/REPL CAR DR OR GATE FRT

    NORTH TRAC.

  • Open

    EV0129 — ENCLOSE WALLS & TOP FRT

    NORTH TRAC.

  • Open

    EV0127 — ENCL/SECURE OPENINGS FRT

    NORTH TRAC.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN061074 PROTECT SIDEWALK DURING CONST
  2. Open City violation record — CN063014 CHIMNEY
  3. Open City violation record — CN103035 STRUCTURAL MEMBER, PIER BLOCK
  4. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  5. Open City violation record — CN062024 PARAPET
  6. Open City violation record — EV1111 MAINTAIN OR REPAIR HYDRO ELEVA
  7. Open City violation record — EV0127 ENCL/SECURE OPENINGS FRT
  8. Open City violation record — EV0129 ENCLOSE WALLS & TOP FRT
  9. Open City violation record — EV0131 REP/REPL CAR DR OR GATE FRT
  10. Open City violation record — EV0135 ILLUMINATE CAB FRT
  11. Open City violation record — 199029 OPEN TYPE VIOLATION
  12. Open City violation record — EV0066 TEST G & S FRT ELE

Recently closed / other violations (sample)

No recent closed violations in the sample.

Around 421 N Wolcott Ave

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:57 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address