Free building report

4131 N Broadway

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 4131 N Broadway, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

23Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (23)

6 of 23 open City violation records are from the last 24 months (since November 2024), shown newest first. 17 older ones are collapsed below — still open, still counted.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    6TH FLOOR AT CORRIDOR / CEILING - WATER DAMAGED TILES AT MULTIPLE LOCATIONS. PER BUILDING CODE SECTION 14X-3-304.3

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    ARRANGE FOR REINSPECTION. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR OF BUILDING INCLUDING UNITS AND ROOF. PER BUILDING CODE SECTION 14A-1-104.7

  • Open

    CN073044 — REPAIR EXTERIOR DOOR HARDWARE

    1ST FLOOR AT WEST ENTRANCE 4145 / DOORS - LOCKED; COMPROMISED EMERGENCY EXIT. 6TH FLOOR AT SOUTH FIRE ESCAPE / DOOR - DEFECTIVE; NOT LATCHING PROPERLY. PER BUILDING CODE SECTION 14X-3-303.17

  • Open

    CN194019 — REPAIR OR REPLACE

    UNIT 524 AT KITCHEN / ELECTRICAL OUTLETS - MISSING COVER PLATES.

  • Rodent-related

    CN136016 — ROACHES

    UNIT 524 / INSECTS - OBSERVED THROUGHOUT. PER BUILDING CODE SECTION 14X-3-308

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF BED BUG INFESTATION. (14A-1-104.7)

Show 17 older open City violation records (before November 2024)
  • Open

    CN194029 — PROVIDE

    PROVIDE PER SECTION 13-96-820, 13-96-830, 13-96-840, 13-96-850, 13-96-870, 100% HANDS-ON CRITICAL EXAM OF ALL FIRE ESCAPES AND EXPOSED METAL PIECES. SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE COMPLIANCE GROUP, 2045 W. WASHINGTON, 60612

  • Open

    CN105025 — REPAIR DOOR FRAME, MULLION

    DOOR LEADING DOWN INTO THE BASEMENT BOILER ROOM SEVERELY DAMAGED.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    REPAIR EXTERIOR WALL - WEST ELEVATION PARAPET WALL LARGE JOINTS MOVEMENT.WEST ELEVATION AT SIXTH FLOOR STRESS CRACKS IN BETWEEN WINDOW JAMBS.WEST ELEVATION RUSTED JULIET BALCONY RAIL CAUSING DAMAGE TO SURROUNDING BRICK.ALL ELEVATIONS FROM GRADE TO STORE FRONT HEADS ALL TERRA COTTA SEVERE WASHED OUT MORTAR, WIDE JOINTS, CRACKED PIECES AND LOOSE SMALL GREEN TILE.NORTHWEST CORNER ROUND AREA SEVERE WASHED OUT MORTAR, WIDE JOINTS.NORTHEAST ROUND CORNER EAST ELEVATION NEAR FIRE ESCAPE AT SECOND FLOOR LARGE BRICK BULG.NORTH ELEVATION AT SECOND FLOOR NEAR NORTHEAST CORNER CRACKED BRICK.SOUTHWEST CORNER SOUTH ELEVATION BRICK CRACKED BULGING OUTWARD.PENTHOUSE ELEVATOR MACHINE ROOM WALL BOWING OVER ENTRANCE DOOR.OBTAIN PLANS AND PERMITS FOR ALL MASONRY REPAIRS.

  • Open

    CN062024 — PARAPET

    SOUTH ELEVATION PARAPET WALL AT FIRE ESCAPE - SPALLING BRICKS AND WASHED OUT MORTAR.

  • Open

    CN105025 — REPAIR DOOR FRAME, MULLION

    INTERIOR STAIRWELL DOOR NEAR 226, DOOR OVER LAPS JAMB.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    INTERIOR 6TH FLOOR CORRIDOR EVIDENCE OF WATER DAMAGE/ MOISTURE PENETRATION.

  • Open

    CN105025 — REPAIR DOOR FRAME, MULLION

    INTERIOR STAIRWELL DOOR NEAR 226, DOOR OVER LAPS JAMB.

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    EXTERIOR ROOF TOP DECK/ PLATFORM ON 6 STORY BUILDING, OF WOOD CONSTUCTION NOT ALLOWED, PROVIDE PLANS AND PERMITS.

  • Open

    CN071014 — REPAIR EXTERIOR PLATFORM

    EXTERIOR ROOF TOP DECK/ PLATFORM ON 6 STORY BUILDING OF WOOD CONSTRUCTION, HAND/ GUARDRAILS OF WOOD LATTICE MATERIAL HOLES OPENINGS AND DEFLECT UNDER LOAD, DECKING LOOSE AND PERTRUDING NAILS.

  • Open

    CN197039 — RELOCATE SMOKE DETECTOR

    STAIRWELL LEADING TO THE ROOF, SMOKE DETECTOR IS ON 6TH FLOOR, SHOULD BE ON ROOF LEVEL CEILING.

  • Open

    CN197039 — RELOCATE SMOKE DETECTOR

    STAIRWELL LEADING TO THE ROOF, SMOKE DETECTOR IS ON 6TH FLOOR, SHOULD BE ON ROOF LEVEL CEILING.

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    DOOR LEADING TO ROOF DECK, IS RUBBING.

  • Open

    CN105015 — REPAIR DOOR, INT.

    2ND FLOOR WEST STAIR DOOR RUBS

  • Open

    CN073044 — REPAIR EXTERIOR DOOR HARDWARE

    3RD FLOOR SOUTH FIRE EXCAPE DOOR CLOSER MISSING LATCH.

  • Open

    CN070014 — REPAIR EXTERIOR STAIR

    ROOF TOP NORTH EAST HANDRAIL LEANING, LOOSE BROKEN TOP RAIL.

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    6TH FLOOR SOUTH FIRE EXCAPE DOOR RUBS.5TH FLOOR NORTH EAST FIRE EXCAPE DOOR RUBS.

  • Open

    CN199029 — Violation

    FAILURE TO PERMIT ACCESS FOR ANNUAL INSPECTION 13-20-020. ATTEMPTED INSPECTION 08/20/07. STICKER LEFT ON DOOR. NO ONE CONTACTED DEPT. OF BUILDINGS TO ALLOW ACCESS. TO ARRANGE INSPECTION PLEASE CALL (312) 743-3538.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN136016 ROACHES
  2. Open City violation record — CN194019 REPAIR OR REPLACE
  3. Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
  4. Open City violation record — CN190029 ARRANGE FOR REINSPECTION REGAR
  5. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  6. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  7. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  8. Open City violation record — CN105025 REPAIR DOOR FRAME, MULLION
  9. Open City violation record — CN194029 PROVIDE
  10. Open City violation record — CN062024 PARAPET
  11. Open City violation record — CN071014 REPAIR EXTERIOR PLATFORM
  12. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  13. Open City violation record — CN105025 REPAIR DOOR FRAME, MULLION
  14. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  15. Open City violation record — CN105025 REPAIR DOOR FRAME, MULLION
  16. Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
  17. Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
  18. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  19. Open City violation record — CN070014 REPAIR EXTERIOR STAIR
  20. Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
  21. Open City violation record — CN105015 REPAIR DOOR, INT.
  22. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  23. Open City violation record — CN199029

Recently closed / other violations (sample)

  • Closed / other

    NC5012 CLASS B DOOR IN STAIRWELL

  • Closed / other

    CN105025 REPAIR DOOR FRAME, MULLION

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN198019 FILE BLDG REGISTRATION

  • Closed / other

    CN101015 REPAIR INTERIOR WALLS/CEILING

  • Closed / other

    CN071014 REPAIR EXTERIOR PLATFORM

  • Closed / other

    CN197039 RELOCATE SMOKE DETECTOR

  • Closed / other

    CN039013 POST APPROVED OCCUPANCY CARD

  • Closed / other

    CN073044 REPAIR EXTERIOR DOOR HARDWARE

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN105015 REPAIR DOOR, INT.

  • Closed / other

    CN105015 REPAIR DOOR, INT.

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN107025 INSTALL EXIT SIGN

  • Closed / other

    CN073014 REPAIR EXTERIOR DOOR

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN107015 ILLUMINATE PUBLIC STAIR/HALL

  • Closed / other

    CN107025 INSTALL EXIT SIGN

Around 4131 N Broadway

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:24 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com