Free building report

3928 N Sheridan Rd

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 3928 N Sheridan Rd, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

11Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (11)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from October 4, 2022. All 11 are collapsed below — still open, still counted.

Show 11 older open City violation records (before November 2024)
  • Open

    CN062024 — PARAPET

    REPAIR EAST AND SOUTH ELEVATION PARAPET WALL. SKIM COAT CRACKING,PEELING AND FALLING OFF BUILDING ONTO PUBLIC WAY

  • Open

    CN031013 — FIRE EXTNGSHR REQ, RESDNTL

    1ST FLOOR COMMERCIAL STORE, CLEANERS, ALL RESIDENTIAL PORTION, - BUILDING THROUGHOUT - MISSING FIRE EXTINGUISHERS.

  • Open

    CN070034 — REPLACE D&H PORCH

    THIS VIOLATION APPLIES FOR BOTH PORCH(S) UNKNOWN FOOTINGS,- PORCH IS PULLING AWAY FROM THE BUILDING, LEDGER BEAMS NOT ATTACHED TO MASONRY, 6X6 BEAMS ARE PULLING AWAY FROM MASONRY WALL, SAME 6X6 BEAMS MISSING STEEL ANGLES OR STEEL STRAPS, UNDERSIZE LUMBER THROUGHOUT THE ENTIRE PORCH, 2X6 FLOOR JOIST WHERE ADDED TO THE EXISTING WORN OUT MEMBERS TO REINFORCE THE FLOOR (INSTALLED WRONG) 6X6 COLUMNS MISSING ALL STEEL CONNECTIONS TO 6X6 BEAMS, ALL CRITICAL CONNECTIONS ARE ONLY NAIL THROUGHOUT ENTIRE PORCH, ALL HANDRAILS ARE WEAK AND DO NOT MEET CBC, 6X6 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS FASTENED WITH NAILS ONLY, - WOOD THROUGHOUT ENTIRE PORCH IS ROTTING, WORN OUT, BEAM AND COLUMN CONNECTIONS ARE MISSING STEEL ANGLES / BRACKETS THROUGHOUT ENTIRE PORCH, UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS - WEAK. - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS ¿ WEAK, GUARD RAILS ARE LESS THEN 42"PLANS AND PERMITS ARE REQUIRED TO REPLACE EXTERIOR PORCH.

  • Open

    CN107035 — MAINTAIN EXIT SIGN ILLUMINATED

    1ST FLOOR CLEANERS, RESTAURANT REAR DOOR, - MAIN ENTRANCE, REAR RESIDENTIAL LOBBY, - BUILDING EXIT SIGNS. - MISSING OR NOT ILLUMINATED.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    TOP OF ALL STAIRWELLS AND REAR PORCH(S) BOTH, - MISSING SMOKE DETECTOR.

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    1ST FLOOR, TAC QUICK RESTAURANT, CLEANERS, MECHANICAL ROOM, - MISSING CARBON MONOXIDE DETECTOR.

  • Open

    CN044013 — PIPE OPENING W/NONCOMBUST MATL

    1ST FLOOR, RESTAURANT, MECHANICAL ROOM, CLEANERS, - CEILING, - OPENINGS AROUND EXPOSED PIPES OR POWER SHAFTING SHALL BE FILLED WITH APPROVED NONCOMBUSTIBLE MATERIAL, OR SHALL BE CLOSED OFF BY CLOSE-FITTING METAL CAPS AT THE CEILING AND FLOOR LINE, AND ON EACH SIDE OF A WALL, CEILING OR PARTITION.AS PER BUILDING CODE 15-8-640

  • Open

    CN107015 — ILLUMINATE PUBLIC STAIR/HALL

    REAR PORCH, - MISSING PUBLIC ILLUMINATION.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR WEST PORCH BEAM FOR 1 BESIDE STAIR INSUFFICIENT COLUMN CONNECTIONS, ROTTING JOIST UNDER LANDING BEFORE 2. UNDERSIZED BEAM FOR SUPPORT OF 1ST 2 LANDINGS. ROTTING JOIST UNDER 2 EAST SIDE. SHIMMERED DECKING SAME LOCATION. STACKED BEAM & COLUMNS AT CENTER (NO STEEL ADDED) BUCKLED & ROTTING DECKS, WORN TREADS. SPLICED HORIZONTAL BEAM UNDER 2 BESIDE STAIRS, LANDINGS BEFORE 3 STACKED ON 4X4 WITH INSUFFICIENT BEAM SUPPORTING OUTSIDE OF LANDING. JOISTS WITH SISTERED MATERIAL ARE NOT CONTINUOUS FROM BEAM TO BEAM. ROTTING PORCH ROOF DECKING. OUT OF PLUMB COLUMNS. REAR EAST PORCH UNDERSIZED JOISTS FOR SPAN, ROTTING DECKS. DECKING SEPARATING FROM JOISTS. ROTTING STRINGERS AT 3. INSUFFICIENTLY SUPPORTED CANTALEVERED SECTIONS. INSUFFICIENT BEAM & COLUMN CONNECTION AT CENTER. ROTTING PORCH ROOF DECKING. REAR CENTER PORCH MISSING HANGERS AT LANDING, NO BOLTS IN LEDGERS OR STRINGERS, STAIRS TO 1ST ONLY 30" WIDE, ROTTING DECKING, INSUFFICIENT BEAM TO COLUMN CONNECTIONS, STAIRS TO 1ST ONLY 30" WIDE, ROTTING DECKING, INSUFFICIENT BEAM TO COLUMN CONNECTIONS, INSUFFICIENT STRINGER ANCHORS, ROTTING RISERS, MISSING HANGERS ON DECKS, ROTTING PORCH ROOF DECKING, 4X4 STRINGER SUPPORT POST NOT SEATED SUFFICIENTLY ON BEAM. REAR PORCHES INSUFFICIENT FOOTINGS/ FOUNDATIONS. ALL REAR PORCH STAIRS INSUFFICIENT DEPT-ONLY 9 1/4" DEEP. REAR PORCHES IN POOR CONDITION RECENT REPAIRS INSUFFICIENT. FULL PLANS AND PERMIT REQUIRED.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    EAST ELEVATION 2 SOUTH MOST BAYS FRACTURE.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    BOTH REAR PORCHES WITHOUT BOLTS TO STRINGERS AND SUPPORT PESTS. JOIST HANGERS MISSING ON ALL INTERMEDIATE LANDINGS. NO BOLTS BEAM TO COLUMN CONNECTIONS. LOOKOUTS MISSING STRAPPING. ALL GUARDRAILS AT 32" MUST BE AT 42". SOME COLUMN WITHOUT VISIBLE FOOTINGS. OBTAIN PERMIT TO REPAIR.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN062024 PARAPET
  2. Open City violation record — CN107015 ILLUMINATE PUBLIC STAIR/HALL
  3. Open City violation record — CN044013 PIPE OPENING W/NONCOMBUST MATL
  4. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  5. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  6. Open City violation record — CN107035 MAINTAIN EXIT SIGN ILLUMINATED
  7. Open City violation record — CN070034 REPLACE D&H PORCH
  8. Open City violation record — CN031013 FIRE EXTNGSHR REQ, RESDNTL
  9. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  10. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  11. Open City violation record — CN070024 REPAIR PORCH SYSTEM

Recently closed / other violations (sample)

  • Closed / other

    VT1010 ARRANGE COMPLETED PERMIT INSP.

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN197087 CARB MONOX DETECT IN RESID

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

Around 3928 N Sheridan Rd

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 11:34 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com