3811 N Ashland Ave
Winter habitability score Open City violation records are on file — read the list, not just the score
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 3811 N Ashland Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (5)
2 of 5 open City violation records are from the last 24 months (since November 2024), shown newest first. 3 older ones are collapsed below — still open, still counted.
- Open
CN070024 — REPAIR PORCH SYSTEM
EAST ELEVATION / 1 LEVEL WOOD PORCH - FOUNDATION STATUS UNKNOWN; LOOSE STAIR RAILS FROM GRADE TO BASEMENT AND FROM GRADE TO 1ST LEVEL. PER BUILDING CODE SECTION 14X-3-303.11
- Open
CN138056 — DEBRIS, EXCESSIVE
EAST ELEVATION AT REAR YARD / REFUSE AND DEBRIS - STORAGE OF CONSTRUCTION MATERIALS. PER BUILDING CODE SECTION 14X-3-307
Show 3 older open City violation records (before November 2024)
- Open
CN070014 — REPAIR EXTERIOR STAIR
REAR BASEMENT STAIRS MISSING SECTIONS OF HAND RAILS AT TOP. GUARD RAILS AROUND OPENINGS FOR BASEMENT STAIRWELLS WITH OPEN LADDER TYPE DESIGN, ONLY 28" IN HEIGHT, GAPS UP TO 1'. MISSING GUARDRAILS AT SOME SECTIONS.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH COLUMNS ON SPALLING, FRACTURED CONCRETE BLOCKS. 2X8 JOISTS SPAN UP TO 12'. COLUMN FIRE CUT FOR LOOKOUT BEAM IN CLOSE PROXIMITY TO JOIST NOTCH. RIM JOISTS ANCHORED WITH NAILS ONLY. LOOKOUT BEAMS ANCHORED TO COLUMNS WITH MENDING PLATES. STAIR PORTION TO 2ND FLOOR WITH LATERAL SWAY. STRINGERS ANCHORED WITH NAILS ONLY. LANDING JOISTS ANCHORED TO BEAMS WITH NAILS ONLY. LANDING JOISTS CUT, NOT CONTINOUS FROM BEAM TO BEAM, WITH SHORT SCAB BRIDGING THE CUTS. RAILINGS ANCHORED WITH NAILS ONLY, LOOSE AND DEFLECTING, 35 1/2" IN HEIGHT. ROTTING AND BUCKLING DECKING. ROTTING AND WORN TREADS. STRINGERS, POSTS AT BASE OF STRINGERS AT GROUND WITH NO VISIBLE FOUNDATIONS. OBTAIN COMPLETE PLANS AND PERMIT.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY ANY RESIDENTIAL UNITS, BASEMENT.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN138056 DEBRIS, EXCESSIVE
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN070014 REPAIR EXTERIOR STAIR
Recently closed / other violations (sample)
- Closed / other
CN064014 REPAIR CORNICE
Around 3811 N Ashland Ave
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:23 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.