All open City violation records (4)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from June 3, 2010. All 4 are collapsed below — still open, still counted.
Show 4 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY RESIDENTIAL.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH- 6X6 LOOKOUT BEAMS SPAN 7'7". 2X8 JOISTS SPAN 10'. BEAMS TO COLUMN CONNECTIONS WITH FIRE CUT AND JOIST NOTCH IN CLOSE PROXIMITY. STRINGERS ANCHORED WITH NAILS ONLY. RAILINGS ANCHORED WTH NAILS ONLY. GUARD RAILS 39" IN HEIGHT. 1' LAPP JOINTS WITH ONLY 2 BOLTS. LANDING BEAMS WITH NAILS AS ONLY CONNECTION TO COLUMNS. SOME JOISTS MISSING ANCHORS FOR HANGERS. AT DECK LEVELS 1,2 AND 3 STRINGER HEADERS NOT IN MASONRY POCKETS BUT ARE SUPORTED BY DECK JOISTS WHICH SPAN PAST LOOKOUT BEAMAS MUCH AS 4' BEFORE STRINGER HEADER IS NAILED TO END OF JOISTS WITH NO OTHER SUPPORT. AT 2 THE JOISTS SUPPORTING THE STRINGER HEADER ARE NOT CONTINOUS, BUT ARE PARTIAL SISTERED. A TRIPLE 2X8 SPANS PAST LOOKOUT BEAM 6' AND IS THEN SUPPORTED BY 4X4 RAILING POST WHICH EXTENDS UP TO THE 3RD LEVEL. OBTAIN COMPLETE PLANS AND PERMIT.
- Open
EL0096 — OBTAIN PERMIT BEFORE SIGN WORK
FLAT SIGN APPROXIMATE 8 X 20' READS ADVERTISEMENT BOOST MOBILE 13-20-520 AND 13-20-550
- Open
EL0096 — OBTAIN PERMIT BEFORE SIGN WORK
FLAT SIGN APPROXIMATE 8 X 25' READS ADVERTISEMENT BOOST MOBILE 13-20-520 AND 13-20-550
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — EL0096 OBTAIN PERMIT BEFORE SIGN WORK
- Open City violation record — EL0096 OBTAIN PERMIT BEFORE SIGN WORK
Recently closed / other violations (sample)
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN031023 FIRE EXTNGSHR RECHARGE & TAG
Around 3658 N Clark St
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:41 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.