All open City violation records (26)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from May 24, 2022. All 26 are collapsed below — still open, still counted.
Show 26 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
3641 N./ ARRANGE PREMISE INSPECTIONMOST APARTMENTS - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS.
- Open
CN074024 — PROVIDE GUARD RAIL 42 IN HIGH
ELEVATED WOOD PLATFORM THAT IS 32" ABOVE GRADE WILL REQUIRE A GUARDRAIL AND HANDRAIL ON BOTH SIDES OF STAIR.
- Open
CN061014 — REPAIR EXTERIOR WALL
EAST WALL HAS LOOSE AND MISSING MORTAR.
- Open
CN194029 — PROVIDE
NON-LOAD BEARING PARTITION WALLS LACKING PROPER FIRE SEPARATION. 7(15-8-260), 7(15-8-270), 7(15-8-120), 7(15-8-190), 7(15-8-240).
- Open
CN017012 — INTERIOR FINISH FIRERESISTANCE
HANGING CURTAINS. (15-8-370, 15-12-340) CLOTH CURTAINS HANGING FROM WOODEN STRUCTURE - ALL MUST BE FIRE RATED.
- Open
CN194019 — REPAIR OR REPLACE
(15-8-460) PROVIDE PROPER FIRE RESISTANCE FOR RAISED PLATFORM.
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
OBTAIN PROPER MASONARY PERMIT FOR WIDENING OF EXIT DOORS TO PROPER WIDTHS.
- Open
PL237020 — PROPER MATRL WATER SUPPLY PIPE
UNAPPROVED FLEXIBLE WATER SUPPLIES AT SOUTHEAST CORNER OF NIGHT CLUB BAR HAND SINK. UNAPPROVED FLEXIBLE WATER SUPPLIES AT UNISEX BATHROOM TOILET.
- Open
PL234002 — SOIL/WASTE,VENT PIPE MATRL
UNAPPROVED FIXTURE TRAP AT SOUTHEAST CORNER OF NIGHT CLUB BAR 3-COMPARTMENT SINK. UNAPPROVED PVC PIPING AND RUBBER COUPLING AT KITCHEN AREA 3-COMPARTMENT SINK. UNAPPROVED PVC PIPING AT SUMP PUMP IN BASEMENT AREA.
- Open
PL159017 — REPLACE DEFECTIVE PLBG FIXTURE
TOILET TANK LID MISSING ON 1 TOILET AT WOMEN'S BATHROOM. 3 CRACKED OR CHIPPED URINALS IN MENS BATHROOM.
- Open
PL233034 — PROVIDE INDIRECT WASTE CONNECT
GARDEN HOSE ATTACHED TO MOP SINK IN LAUNDRY ROOM.
- Open
PL232011 — OBTAIN PERMIT FOR PLUMBING
OBTAIN PERMIT BEFORE CONSTRUCTING, ALTERING OR USING PLUMBING SYSTEM.
- Open
PL239010 — ENGAG LIC & BOND PLMBNG CNTRC
OBTAIN LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING.
- Open
EL0024 — INSTALL ILLUMINATION
INSTALL ILLUMINATION TO ENTIRE BASEMENT.
- Open
EL0085 — Violation
(18-27-110.26) REMOVE ALL CLUTTER AND FOREIGN OBJECTS IN ELECTRICAL ROOM, NOT TO BE USED AS STORAGE ROOM.
- Open
EL0027 — RESTORE EXIT AND EM
MAINTAIN EMERGENCY LIGHTING SYSTEM III IN OPERABLE CONDITION.
- Open
EL0066 — UNAPPROVED CORDS
REMOVE ALL UNAPPROVED EXTENSION CORDS AND POWER STRIPS AND INSTALL ADDITIONAL RECEPTACLES TO AVOID USE OF CORDS.
- Open
EL0085 — Violation
(18-27-110.12E) REMOVE ALL ABANDONED ELECTRICAL FIXTURES AND EQUIPMENT.
- Open
EL0085 — Violation
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS.
- Open
PL234018 — INSTALL VENT PIPE FOR TRAP
OPEN SITE DRAINS SERVING 1ST FLOOR ICE MACHINES MISSING VENT FOR P-TRAPS IN BASEMENT AREA.
- Open
CN031023 — FIRE EXTNGSHR RECHARGE & TAG
FIRE EXTINGUISHER NOT TAGGED.
- Open
CN031013 — FIRE EXTNGSHR REQ, RESDNTL
FIRE EXTINGUISHER NOT MOUNTED.
- Open
CN194029 — PROVIDE
BASEMENT CEILING HAS BREACH TO CONCRETE WITH HOLES AND PENETRATIONS. 6(13-60-200)
- Open
CN140016 — DWELLING CLEAN AND SANITARY
BASEMENT CEILING HAS BLACK MOLD LIKE SUBSTANCE. THIS POSES A HEALTH HAZARD.
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
EAST ENCLOSED BASEMENT STAIRWAY HAS MISSING AND LOOSE BRICK AND MORTAR WITH EFFLORESCENCE TO THE BRICK.
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
TWO EAST REAR MARKED EXITS REDUCED 33 1/2" DOOR TO JAMB. OVERALL OPENING JAMB TO JAMB AT 35".
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN140016 DWELLING CLEAN AND SANITARY
- Open City violation record — CN194029 PROVIDE
- Open City violation record — CN031013 FIRE EXTNGSHR REQ, RESDNTL
- Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
- Open City violation record — PL234018 INSTALL VENT PIPE FOR TRAP
- Open City violation record — EL0085
- Open City violation record — EL0085
- Open City violation record — EL0066 UNAPPROVED CORDS
- Open City violation record — EL0027 RESTORE EXIT AND EM
- Open City violation record — EL0085
- Open City violation record — EL0024 INSTALL ILLUMINATION
- Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
- Open City violation record — PL232011 OBTAIN PERMIT FOR PLUMBING
- Open City violation record — PL233034 PROVIDE INDIRECT WASTE CONNECT
- Open City violation record — PL159017 REPLACE DEFECTIVE PLBG FIXTURE
- Open City violation record — PL234002 SOIL/WASTE,VENT PIPE MATRL
- Open City violation record — PL237020 PROPER MATRL WATER SUPPLY PIPE
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN194019 REPAIR OR REPLACE
- Open City violation record — CN017012 INTERIOR FINISH FIRERESISTANCE
- Open City violation record — CN194029 PROVIDE
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
Recently closed / other violations (sample)
- Closed / other
CN107035 MAINTAIN EXIT SIGN ILLUMINATED
- Closed / other
CN100303 ASSEMBLY UNIT CO DETECTOR
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN039013 POST APPROVED OCCUPANCY CARD
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
EL0029 EXPOSED WIRING
- Closed / other
EL0033 SECURE RACEWAY
- Closed / other
EL0065 LIVE FRONT SWITCHBOARD
- Closed / other
EL0084 SEE INSPECTOR COMMENTS
- Closed / other
CN101015 REPAIR INTERIOR WALLS/CEILING
- Closed / other
EL0086
- Closed / other
EL0091 NO PERMIT WIRING
- Closed / other
EL0046 APPLIANCE INSIGHT DISCONNECT
- Closed / other
EL0084 SEE INSPECTOR COMMENTS
- Closed / other
EL0085
- Closed / other
CN074024 PROVIDE GUARD RAIL 42 IN HIGH
- Closed / other
CN102015 INT WALL/CEILING PEELING PAINT
- Closed / other
CN067014 REPAIR ROOF
- Closed / other
CN101025 INT WALL/CEILING CHIP PLASTER
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
Around 3641 N Halsted St
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 7:31 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.