3512 N Sheffield Ave
Winter habitability score Multiple habitability signals in public records
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 3512 N Sheffield Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (17)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from April 28, 2017. All 17 are collapsed below — still open, still counted.
Show 17 older open City violation records (before November 2024)
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
OBTAIN PERMIT FOR: (1) CONVERSION OF TWO FIRST FLOOR APARTMENTS AND BASEMENT STORAGE SPACES TO A HOSTEL WITH 9 GUEST ROOMS, COMMUNAL KITCHEN/DINING AREA, RECREATIOIN ROOM AND LAUNDRY ROOM. (2) ENCLOSURE OF REAR WOOD PORCH SYSTEMS TO PROVIDE ADDITIONAL LIVING AREA FOR UNITS ON FIRST, SECOND AND THIRD FLOORS. (3) CONSTRUCTION OF DECK ON ROOF OF GARAGE. (4) CONSTRUCTION OF ENCLOSURE LINKING GARAGE TO THE BUILDING.
- Open
CN194029 — PROVIDE
PROVIDE FOUR HOUR FIRE RESISTIVE SEPARATION BETWEEN REAR ATTACHED GARAGE AND FRONT BUILDING. AT THE SOUTH BASEMENT THERE IS A CONNECTING LINK BETWEEN THE BUILDING AND THE GARAGE. SEE EXPOSED WOOD FRAMING AT UNDERSIDE OF ENCLOSED PORCH WHICH IS THE FLOOR FOR GUEST ROOM #11 ON THE FIRST FLOOR. AND SEE UNPROTECTED DOOR OPENINGS BETWEEN BASEMENT AND GARAGE. 13-56-280
- Open
NC3022 — ADDITIONAL EXIT
REAR EXIT FROM SOUTH BASEMENT ELIMINATED BY CONSTRUCTION OF CONNECTING LINK TO GARAGE. PROVIDE ADDITIONAL MEANS OF EGRESS.
- Open
CN194029 — PROVIDE
THE REAR EXIT FROM NORTH BASEMENT IS AT UNDERSIDE OF ENCLOSED PORCH AND LEADS TO WOOD STAIR SYSTEM THAT IS 25-1/2 INCHES WIDE AND WITH INADEQUATE HEADROOM. 13-160-220(B)(2) 13-160-150
- Open
CN194029 — PROVIDE
AT THE REAR EXIT PATH IN NORTH BASEMENT PROVIDE 36 INCH WIDE DOORS. THE DOOR TO THE LAUNDRY ROOM IS 32 INCES WIDE AND THE EXTERIOR DOOR IS 31 INCHES WIDE. 13-160-220(2)
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
REMOVE TWO SLIDE BOLTS FROM REAR EXIT DOOR IN NORTH BASEMENT.
- Heat-related
CN010012 — 1-HR HEATING PLANT ENCLOSURE
AT BASEMENT BOILER ROOM THE FIRE SEPARATION IS INCOMPLETE. SE SECTIONS OF DRYWALL NOT FIRE TAPED AND MISSING DRYWALL AT NORTHWEST CORNER.
- Heat-related
CN011012 — HEATING PLANT/BOILER ROOM DOOR
INSTALL SELF CLOSING, SELF LATCHING CLASS B FIRE DOOR ASSEMBLY AT BASEMENT BOILER ROOM. EXISTING CONSTRUCTION IS UNRATED DOOR WITHOUT SELF CLOSING HARDWARE AND FRAME IS WOOD WITH AN APPLIED WOOD DOOR STOP.
- Open
NC1010 — CONTRARY TO ORIGINAL PLAN
THIS IS A THREE STORY BUILDING THAT ORIGINALLY CONTAINED SIX APARTMENTS. TWO FIRST FLOOR APARTMENTS AND BASEMENT STORAGE SPACES CONVERTED TO A HOSTEL WITH ACCOMMODATIONS FOR AT LEAST 43 PEOPLE. AT FIRST FLOOR NORTH THERE IS THE GUEST RECEPTION WITH A DESK CLERK, COMMUNAL KITCHEN/DINING AREA, BATHROOM AND TWO GUEST ROOMS WITH A TOTAL OF 7 BUNKBEDS. AT FIRST FLOOR SOUTH THERE ARE FOUR GUEST ROOMS WITH A TOTAL OF 10 BUNKBEDS AND TWO WASHROOMS. AT NORTH BASEMENT THERE ARE TWO GUEST ROOMS WITH A QUEEN BED IN ONE ROOM AND FOUR SINGLE BEDS IN THE SECOND ROOM, BATHROOM AND LAUNDRY ROOM. AT SOUTH BASEMENT THERE IS A RECREATION AREA, BATHROOM AND GUEST ROOM WITH 2 BUNKBEDS. THE TWO APARTMENTS ON THE FIRST FLOOR WERE RADICALLY ALTERED AND THE BASEMENT SPACES TRANSFORMED FROM UNFINISHED STORAGE TO COMPLETE THE CONVERSION. WORK INCLUDED, BUT WAS NOT LIMITED TO INTERIOR DEMOLITION, ERECTION OF PARTITIONS, PARTIAL ENCLOSURE OF REAR PORCHES, NEW WALL, FLOOR AND CEILING FINISHES AND ALTERATIONS TO THE ELECTRICAL AND PLUMBING SYSTEMS.
- Open
CN194029 — PROVIDE
SUBMIT DOCUMENTATION THAT CONVERSION OF TWO FIRST FLOOR APARTMENTS AND BASEMENT STORAGE SPACES TO A HOSTEL MEETS REQUIREMENTS FOR NATURAL LIGHT AND VENTILATION. 13-172-060 THRU 13-172-100
- Open
CN194029 — PROVIDE
SUBMIT REPORT TO DEPARTMENT OF BUILDINGS THAT ANALYZES OCCUPANCY CONTENT AT FIRST FLOOR AND BASEMENT. THESE AREA'S ARE USED AS A HOSTEL WITH 9 GUEST ROOMS ACCOMMODATING AT LEAST 43 PEOPLE. REPORT TO DETERMINE IF THERE IS OVERCROWDING OR CURRENT USE MEETS MINIMUM SPACE REQUIREMENTS. 13-56-300 13-56-320 13-196-480 13-196-490
- Open
CN013012 — UNDERSIDE STAIR 1HR FIRE RES
AT FRONT STAIRWELL TO BASEMENT INSTALL 5/8 INCH TYPE X DRYWALL AT UNDERSIDE OF STAIR SYSTEM.
- Open
CN194039 — REMOVE
REMOVE FIXED WINDOW UNITS ABOVE GUEST ROOM ENTRY DOORS AT ROOM #1 AND ROOM #8 AND INFILL WITH SAME CONSTRUCTION AS PARTITION WALL. 15-8-150
- Open
CN194029 — PROVIDE
INSTALL SMOKE DETECTORS WITH ESCAPE LIGHT IN EACH SLEEPING ROOM, STAIRWELL AND COMMON AREAS. IN ADDITION PROVIDE SMOKE DETECTORS DESIGNED TO SERVE HEARING IMPAIRED PERSONS PER 4-6-290 (F)(5)(I). EXISTING UNITS DO NOT MEET THESE REQUIREMENTS.
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
POST BUIDING MANAGEMENT IDENTIFICATION AT EXTERIOR.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING HAS NOT BEEN REGISTERED WITH THE DEPARTMENT OF BUILDINGS.
- Open
NC5012 — CLASS B DOOR IN STAIRWELL
REPLACE MISSING DOOR AT FIRST FLOOR FRONT OPENING TO BASEMENT STAIRWELL.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — NC5012 CLASS B DOOR IN STAIRWELL
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN194029 PROVIDE
- Open City violation record — CN194039 REMOVE
- Open City violation record — CN013012 UNDERSIDE STAIR 1HR FIRE RES
- Open City violation record — CN194029 PROVIDE
- Open City violation record — CN194029 PROVIDE
- Open City violation record — NC1010 CONTRARY TO ORIGINAL PLAN
- Open heat-related City violation record — CN011012 HEATING PLANT/BOILER ROOM DOOR
- Open heat-related City violation record — CN010012 1-HR HEATING PLANT ENCLOSURE
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN194029 PROVIDE
- Open City violation record — CN194029 PROVIDE
- Open City violation record — NC3022 ADDITIONAL EXIT
- Open City violation record — CN194029 PROVIDE
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
Recently closed / other violations (sample)
- Closed / other
CN062024 PARAPET
Around 3512 N Sheffield Ave
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 10:57 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.