All open City violation records (19)
5 of 19 open City violation records are from the last 24 months (since November 2024), shown newest first. 14 older ones are collapsed below — still open, still counted.
- Open
NC4012 — 1-HR STAIR ENCLOSURE, <3 STORY
FRONT STAIRWAY 2ND&3RD FLOORS - PROVIDE CLASS B DOOR WITH FRAMES AND CLOSURES . 14B-10-1023.2
- Open
CN197039 — RELOCATE SMOKE DETECTOR
FRONT STAIRWAY - SMOKE ALARM TO LOW. 14X-5-504.8
- Open
CN013012 — UNDERSIDE STAIR 1HR FIRE RES
FRONT BASEMENT - BREACHES AT STAIRWAY. 14X-5-505.9.6
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
3RD FLOOR - LOOSE AND DAMAGED WALLS AND CEILINGS. 14X-3-304.3
- Open
NC2053 — COMPLETE WORK
PERMIT B816458 ISSUED 12/20/95 WAS NEVER FINALLED OR INSPECTED. OBTAIN OR REOPEN PERMIT TO COMPLETE WORK. 14A-4-413.9, 14A-4-401.1
Show 14 older open City violation records (before November 2024)
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
OBTAIN PERMIT FOR TENT ERECTED IN YARD AT RESTAURANT, ORIGINALLY CITED ON 7-17-2019 AND REINSPECTION ON 1-6-2020 FOUND NOT IN COMPLIANCE
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
OBTAIN PERMIT FOR TENT IN YARD.
- Open
CN194029 — PROVIDE
PROVIDE PER SECTION 13-96-820, 13-96-830, 13-96-840, 13-96-850, 13-96-870, 100% HANDS-ON CRITICAL EXAM OF SEVERELY STEEL RUSTED PORCH. SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE COMPLIANCE GROUP, 2045 W. WASHINGTON, 60612
- Open
CN061014 — REPAIR EXTERIOR WALL
REPAIR EXTERIOR WALL - EAST ELEVATION METAL CORNICE RUSTED HAS COME APART ON SOUTH ELEVATION NEAR SOUTHEAST CORNER AND CORNICE IS RUSTED WITH HOLESEAST ELEVATION ORNAMETAL METAL SIDING RUSTED.EAST ELEVATION STONE WASHED OUT MORTAR.OBTAIN PERMIT FOR ALL REPAIRS
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
PLANS AND PERMITS FOR REAR YARD LARGE TENT/SHED SHELTER.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS.
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
REAR YARD - 1 STORY 20X20 STRUCTURE ERECTED WITHOUT PERMIT . PERMIT IS NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL.
- Open
CN070034 — REPLACE D&H PORCH
3 STORY REAR PORCH- ENCLOSED WITH WOOD LATH AND WITH PLASTIC SHEATHING FROM GRADE TO 3RD FLOOR . COLUMNS OUT OF PLUMB , BOWING ,AND TWISTING. FOUNDATION FOOTING STATUS UNKNOWN. COLUMN HAVE INADEQUATE HALF LAP JOINTS WITH ONLY 2 BOLTS USED AND UNDERSIZED AT 1/2 INCH IN DIAMETER .LEDGER BEAMS MISSING BOLTS AT EXTERIOR WALLS , PULLING AWAY FROM WALL (DANGEROUS CONDITION ) WITH GAPS BETWEEN THEM UP TO 6 INCHES WIDE . BEAMS TO COLUMN CONNECTION UNKNOWN (COVERED WITH PLASTIC) . UPPER AND BOTTOM STRINGER INADEQUATELY SUPPORTED TO HEADER AND COLUMNS WITH NAILS.ENTIRE FLIGHT OF STAIRS FROM GRADE TO 3RD FLOOR SETTLED 4-6 INCHES FROM ITS INTENDED POSITION (DANGEROUSLY OUT OF PLUMB ).DECK BOARDS - ROTTING, DAMAGED , AND WEAK. RAILING SECTIONS FROM GRADE TO 3RD FLOOR 6 INCH GAP BETWEEN TOP OF TREAD AND BOTTOM OF RAIL. APPLIANCES, REFRIGERATORS , FURNITUREAND PANTRY ITEMS BEING STORED ON REAR PORCH FROM 1ST TO 3RD ACTING AS CONCENTRATING LOAD (DANGEROUS CONDITION).SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH.
- Open
CN197019 — INSTALL SMOKE DETECTORS
FRONT INTERIOR STAIRWAY - 3RD FLOOR/ SMOKE DETECTOR MISSING.
- Open
CN014012 — NO CLOSET/STORAGE UNDER STAIR
FRONT INTERIOR STAIRWAY AND REAR PORCH- FROM GRADE TO 3RD FLOOR - EXCESSIVE STORAGE ON REAR DECKS AND FRONT STAIR LANDINGS.
- Open
CN197019 — INSTALL SMOKE DETECTORS
STAIRWELL- MISSING SMOKE DETECTORS 3RD FLR. APT.
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR PORCH SYSTEM WITH UNKOWN FOOTING UNDER THE COLUMNS COLUMNS WITH OUT THE PROPER LAP JOINTS AND BOLTS. BEAMS WITH OUT TIE STRAPS AT COLUMNS. ALL FLIGHT OF STAIRS OUT OT LEVEL. ALL STRINGERS CONNECTIONS NOT BOLTED. ROTTED SECTIONS UNEVEN RISER HEIGHT SECTIONS GUARDAND HANDRAILS WEAK AND DISCONNECTED ANCHOR AREAS. RIM JOISTS NOT BOLT MISSING HANGERS ROTTED EXT. WALL SIDING ROTTED. DUE TO THE DETIRIORATED AND MANY DEFLECT AND ARCHITECUTURAL PLANS IS NOW REQUIRED.
- Open
CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU
BSMT. REAR CEILING WITH LARGE AREAS DAMAGED EXPOSED LATH.
- Open
CN197087 — CARB MONOX DETECT IN RESID
BSMT. AREA- MISSING CARBON MONOXIDE DETECTOR.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — NC2053 COMPLETE WORK
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN013012 UNDERSIDE STAIR 1HR FIRE RES
- Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
- Open City violation record — NC4012 1-HR STAIR ENCLOSURE, <3 STORY
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN194029 PROVIDE
- Open City violation record — CN014012 NO CLOSET/STORAGE UNDER STAIR
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
Recently closed / other violations (sample)
- Closed / other
CN194029 PROVIDE
- Closed / other
CN061014 REPAIR EXTERIOR WALL
- Closed / other
NC2011 PLANS & PERMITS REQ - CONTRCTR
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Closed / other
NC5012 CLASS B DOOR IN STAIRWELL
- Closed / other
CN100303 ASSEMBLY UNIT CO DETECTOR
- Closed / other
CN039013 POST APPROVED OCCUPANCY CARD
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
- Closed / other
CN011012 HEATING PLANT/BOILER ROOM DOOR
Around 3411 N Halsted St
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:30 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.