Free building report

3411 N Halsted St

Winter habitability score Some issues on record — read the details

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 3411 N Halsted St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

19Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (19)

5 of 19 open City violation records are from the last 24 months (since November 2024), shown newest first. 14 older ones are collapsed below — still open, still counted.

  • Open

    NC4012 — 1-HR STAIR ENCLOSURE, <3 STORY

    FRONT STAIRWAY 2ND&3RD FLOORS - PROVIDE CLASS B DOOR WITH FRAMES AND CLOSURES . 14B-10-1023.2

  • Open

    CN197039 — RELOCATE SMOKE DETECTOR

    FRONT STAIRWAY - SMOKE ALARM TO LOW. 14X-5-504.8

  • Open

    CN013012 — UNDERSIDE STAIR 1HR FIRE RES

    FRONT BASEMENT - BREACHES AT STAIRWAY. 14X-5-505.9.6

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    3RD FLOOR - LOOSE AND DAMAGED WALLS AND CEILINGS. 14X-3-304.3

  • Open

    NC2053 — COMPLETE WORK

    PERMIT B816458 ISSUED 12/20/95 WAS NEVER FINALLED OR INSPECTED. OBTAIN OR REOPEN PERMIT TO COMPLETE WORK. 14A-4-413.9, 14A-4-401.1

Show 14 older open City violation records (before November 2024)
  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    OBTAIN PERMIT FOR TENT ERECTED IN YARD AT RESTAURANT, ORIGINALLY CITED ON 7-17-2019 AND REINSPECTION ON 1-6-2020 FOUND NOT IN COMPLIANCE

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    OBTAIN PERMIT FOR TENT IN YARD.

  • Open

    CN194029 — PROVIDE

    PROVIDE PER SECTION 13-96-820, 13-96-830, 13-96-840, 13-96-850, 13-96-870, 100% HANDS-ON CRITICAL EXAM OF SEVERELY STEEL RUSTED PORCH. SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE COMPLIANCE GROUP, 2045 W. WASHINGTON, 60612

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    REPAIR EXTERIOR WALL - EAST ELEVATION METAL CORNICE RUSTED HAS COME APART ON SOUTH ELEVATION NEAR SOUTHEAST CORNER AND CORNICE IS RUSTED WITH HOLESEAST ELEVATION ORNAMETAL METAL SIDING RUSTED.EAST ELEVATION STONE WASHED OUT MORTAR.OBTAIN PERMIT FOR ALL REPAIRS

  • Open

    NC2011 — PLANS & PERMITS REQ - CONTRCTR

    PLANS AND PERMITS FOR REAR YARD LARGE TENT/SHED SHELTER.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS.

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    REAR YARD - 1 STORY 20X20 STRUCTURE ERECTED WITHOUT PERMIT . PERMIT IS NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL.

  • Open

    CN070034 — REPLACE D&H PORCH

    3 STORY REAR PORCH- ENCLOSED WITH WOOD LATH AND WITH PLASTIC SHEATHING FROM GRADE TO 3RD FLOOR . COLUMNS OUT OF PLUMB , BOWING ,AND TWISTING. FOUNDATION FOOTING STATUS UNKNOWN. COLUMN HAVE INADEQUATE HALF LAP JOINTS WITH ONLY 2 BOLTS USED AND UNDERSIZED AT 1/2 INCH IN DIAMETER .LEDGER BEAMS MISSING BOLTS AT EXTERIOR WALLS , PULLING AWAY FROM WALL (DANGEROUS CONDITION ) WITH GAPS BETWEEN THEM UP TO 6 INCHES WIDE . BEAMS TO COLUMN CONNECTION UNKNOWN (COVERED WITH PLASTIC) . UPPER AND BOTTOM STRINGER INADEQUATELY SUPPORTED TO HEADER AND COLUMNS WITH NAILS.ENTIRE FLIGHT OF STAIRS FROM GRADE TO 3RD FLOOR SETTLED 4-6 INCHES FROM ITS INTENDED POSITION (DANGEROUSLY OUT OF PLUMB ).DECK BOARDS - ROTTING, DAMAGED , AND WEAK. RAILING SECTIONS FROM GRADE TO 3RD FLOOR 6 INCH GAP BETWEEN TOP OF TREAD AND BOTTOM OF RAIL. APPLIANCES, REFRIGERATORS , FURNITUREAND PANTRY ITEMS BEING STORED ON REAR PORCH FROM 1ST TO 3RD ACTING AS CONCENTRATING LOAD (DANGEROUS CONDITION).SUBMIT PLANS AND OBTAIN PERMIT TO REPLACE REAR PORCH.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    FRONT INTERIOR STAIRWAY - 3RD FLOOR/ SMOKE DETECTOR MISSING.

  • Open

    CN014012 — NO CLOSET/STORAGE UNDER STAIR

    FRONT INTERIOR STAIRWAY AND REAR PORCH- FROM GRADE TO 3RD FLOOR - EXCESSIVE STORAGE ON REAR DECKS AND FRONT STAIR LANDINGS.

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    STAIRWELL- MISSING SMOKE DETECTORS 3RD FLR. APT.

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH SYSTEM WITH UNKOWN FOOTING UNDER THE COLUMNS COLUMNS WITH OUT THE PROPER LAP JOINTS AND BOLTS. BEAMS WITH OUT TIE STRAPS AT COLUMNS. ALL FLIGHT OF STAIRS OUT OT LEVEL. ALL STRINGERS CONNECTIONS NOT BOLTED. ROTTED SECTIONS UNEVEN RISER HEIGHT SECTIONS GUARDAND HANDRAILS WEAK AND DISCONNECTED ANCHOR AREAS. RIM JOISTS NOT BOLT MISSING HANGERS ROTTED EXT. WALL SIDING ROTTED. DUE TO THE DETIRIORATED AND MANY DEFLECT AND ARCHITECUTURAL PLANS IS NOW REQUIRED.

  • Open

    CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU

    BSMT. REAR CEILING WITH LARGE AREAS DAMAGED EXPOSED LATH.

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    BSMT. AREA- MISSING CARBON MONOXIDE DETECTOR.

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — NC2053 COMPLETE WORK
  2. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  3. Open City violation record — CN013012 UNDERSIDE STAIR 1HR FIRE RES
  4. Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
  5. Open City violation record — NC4012 1-HR STAIR ENCLOSURE, <3 STORY
  6. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  7. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  8. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  9. Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
  10. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  11. Open City violation record — CN194029 PROVIDE
  12. Open City violation record — CN014012 NO CLOSET/STORAGE UNDER STAIR
  13. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  14. Open City violation record — CN070034 REPLACE D&H PORCH
  15. Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
  16. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  17. Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
  18. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  19. Open City violation record — CN197019 INSTALL SMOKE DETECTORS

Recently closed / other violations (sample)

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    NC2011 PLANS & PERMITS REQ - CONTRCTR

  • Closed / other

    CN190019 ARRANGE PREMISE INSPECTION

  • Closed / other

    CN012022 1HR FLR OVER BSMT, 1 OR 2 DU

  • Closed / other

    NC5012 CLASS B DOOR IN STAIRWELL

  • Closed / other

    CN100303 ASSEMBLY UNIT CO DETECTOR

  • Closed / other

    CN039013 POST APPROVED OCCUPANCY CARD

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN011012 HEATING PLANT/BOILER ROOM DOOR

Around 3411 N Halsted St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 3:30 PM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com