3339 N Clark St
Winter habitability score Open City violation records are on file — read the list, not just the score
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 3339 N Clark St, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (3)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from May 26, 2016. All 3 are collapsed below — still open, still counted.
Show 3 older open City violation records (before November 2024)
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
MISSING OWNER¿S INFORMATION.
- Open
CN070034 — REPLACE D&H PORCH
REAR PORCH IS OUT OF PLUMB AND DANGEROUSLY LEANING OVER THE REAR SIDE WALK, ( PORCH MIGHT COLLAPSE AT ANY TIME WITHOUT WARNING ) COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES: FOUNDATION STATUS UNKNOWN,- 4X4 COLUMNS ARE CUT BETWEEN FLOORS, - AT FIRST AND SECOND FLOOR CONNECTIONS BETWEEN 6X6 COLUMN AND 6X6 BEAM SUPPORTING THE FIRST AND 2ND FLOORS, BEAMS COMPLETELY ROT AND FAIL, AT THE TIME OF INSPECTION ONE 2X4 ONLY NAIL IS HOLDING THE CONNECTION MENTION ABOVE, - 1ST AND 2ND FLOOR JOIST FAIL CAUSING THE FLOOR TO BE LEANING AND VERY UNSTABLE, - COLUMNS ARE OUT OF PLUMB, BOWING AND TWISTING, 6X6 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS FASTENED WITH NAILS ONLY, LEDGER BEAMS NOT FASTENED TO BUILDING EXTERIOR WALLS, WOOD AT CRITICAL CONNECTIONS ARE ROTTING, BEAM AND COLUMN CONNECTIONS ARE MISSING STEEL ANGLES - BRACKETS THROUGHOUT ENTIRE PORCH. UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS ARE TWISTED MISSING MID SPAN BRIDGING, - ALL CONNECTIONS AT ROOF ARE TOE NAIL, MISSING BRACKETS, OR STRAPS AT MASONRY CONNECTION, PLANS AND PERMITS ARE REQUIRED TO REPLACE EXTERIOR PORCH.
- Open
CN016012 — PROVIDE CLASS A FIRE DOOR
AT 1ST FLOOR RESTAURANT (3 ) THREE BUILDINGS ARE PART OF THE RESTAURANT, - BETWEEN 3335 - 3337 - 3339 THE FOUR (4) HOUR FIRE RATING MASONRY WALL IS BREACH, PROVIDE CLASS "A" AUTOMATIC FIRE RATED DOORS WHERE THE BREACH OCCURRED AT EACH BUILDING. PLANS AND PERMIT REQUIRED
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN016012 PROVIDE CLASS A FIRE DOOR
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
Recently closed / other violations (sample)
- Closed / other
CN065024 MAINTAIN PROJECTIONS
Around 3339 N Clark St
- Lake View building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:22 PM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.