2764 N Lincoln Ave
Winter habitability score Some issues on record — read the details
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 2764 N Lincoln Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (12)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from July 24, 2019. All 12 are collapsed below — still open, still counted.
Show 12 older open City violation records (before November 2024)
- Open
ES1801 — NO PERMIT PROJECTING SIGN
(1) PROJ PUBLIC 4' X 4' SIGN READS:"SHEN SHEN HEALTH & HARMONY"
- Open
CN070034 — REPLACE D&H PORCH
REAR WOOD PORCH, - COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES, - FOUNDATION STATUS UNKNOWN, - COLUMNS INSIDE CLINIC ARE NOT VISIBLE, ALL WALLS ARE WRAP WITH DRYWALL, - PORCH IS OUT OF PLUMB AND DANGEROUSLY LEANING TO THE LEFT, - COLUMNS ARE OUT OF PLUMB, BOWING AND TWISTING, COLUMNS HAVE INADEQUATE HALF - LAP JOINTS FASTENED WITH ( 2 ) ½¿ BOLTS ONLY SPLICE IS LESS THE 12¿, 4X4 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS FASTENED WITH NAILS ONLY, LEDGER BEAMS NOT FASTENED TO BUILDING EXTERIOR WALLS,- WOOD THROUGHOUT ALL THE PORCH IS ROTTING, WORN OUT, BEAM AND COLUMN CONNECTIONS ARE MISSING PROPER CONNECTORS, - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ¿ LEDGER BEAMS ARE NOT ATTACHED TO MASONRY, - AT 1ST FLOOR STAIR, - STAIR STRINGERS ARE SPLIT, WOOD IS DRY, RISERS AND TREADS ARE SPLIT, LOOSE, HAND RAILS ARE VERY LOOSE AND UNSAFE, - THERE IS A REPAIR AT THE BOTTOM OF THE STAIR STRINGER WITH A PRE - ENGINEER HANGER WITH SCREWS AND A 1X1 AT THE BOTTOM OF THE STRINGER, - REPAIR WILL NOT SUPPORT THE WEIGHT OF THE STAIR PROPERKY. - AT THE OPPOSITE SIDE STRINGER IS OVER NOTCH SET IMPROPERLY WITH NAILS AND BEARING WITH LESS THEN HALF AND INCH.PLANS AND PERMITS ARE REQUIRED TO REPLACE EXTERIOR PORCH.
- Open
CN031013 — FIRE EXTNGSHR REQ, RESDNTL
INTERIOR STAIRWAYS AND COMMERCIAL SPACE - MISSING FIRE EXTINGUISHERS AND OR EXPIRED (AND OR MISSING) TAGS.
- Open
CN061014 — REPAIR EXTERIOR WALL
ABOVE MAIN ENTRANCE OF THE BUILDING, - MASONRY BELOW FIRE ESCAPE IS BULGING OUT; MASONRY IS OUT OF PLUMB AND DANGEROUSLY LEANING OVER THE PUBLIC SIDEWALK, WITH THE RISK OF COLLAPSE AT ANY TIME WITHOUT WARNING.PLANS AND PERMIT ARE REQUIRED TO REPAIR EXTERIOR WALL.
- Open
CN061024 — SUBMIT 2 COPY STRUCTURAL RPT
AT EAST ELEVATION - MAIN FACADE, - ABOVE MAIN ENTRANCE OF THE BUILDING, - MASONRY BELOW FIRE ESCAPE IS BULGING OUT, MASONRY IS OUT OF PLUMB AND DANGEROUSLY LEANING OVER THE PUBLIC SIDEWALK, WITH THE RISK OF COLLAPSE AT ANY TIME WITHOUT WARNING.PROVIDE EAST ELEVATION - MAIN FACADE EXTERIOR STRUCTURAL REPORT TO INSURE THAT FIRE ESCAPE IS SECURELY ATTACHED TO LOAD BEARING WALL AS WELLS AS TO FIND OUT IF FIRE ESCAPE IS CAUSING MASONRY TO FAIL. PLANS AND PERMIT ARE REQUIRED TO REPAIR EXTERIOR WALL.
- Open
CN060002 — PROVIDE SIDEWALK SHED F/PROTCT
AT 1ST FLOOR MAIN ENTRANCE , - SAFETY CANOPY IS REQUIRED TO INSURE OCCUPANTS AND PUBLIC SAFETY.
- Open
CN197087 — CARB MONOX DETECT IN RESID
1ST FLOOR SHEN SHEN CLINIC MISSING CARBON MONOXIDE DETECTOR ( MECHANICAL ROOM )
- Open
CN197019 — INSTALL SMOKE DETECTORS
1ST FLOOR SHEN SHEN CLINIC MISSING SMOKE DETECTOR
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
MISSING OWNER¿S INFORMATION
- Open
CN107035 — MAINTAIN EXIT SIGN ILLUMINATED
1ST FLOOR SHEN SHEN CLINIC, - FRONT AND REAR DOORS, - EMERGENCY EXIT SIGNS OUT OF SERVICE.
- Open
CN078014 — ILLUMINATE EXIT AREAS
1ST FLOOR SHEN SHEN CLINIC, - EMERGENCY LIGHTS OUT OF SERVICE.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
1ST FLOOR CLINIC SHEN - SHEN, - 1ST FLOOR REAR PORCH WAS ENCLOSED AND CLINIC WAS EXTENDED WITHOUT PLANS AND BUILDING PERMIT, - PROVIDE PLANS AND PERMIT FOR REAR CLINIC ADDITION.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — ES1801 NO PERMIT PROJECTING SIGN
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN078014 ILLUMINATE EXIT AREAS
- Open City violation record — CN107035 MAINTAIN EXIT SIGN ILLUMINATED
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN060002 PROVIDE SIDEWALK SHED F/PROTCT
- Open City violation record — CN061024 SUBMIT 2 COPY STRUCTURAL RPT
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN031013 FIRE EXTNGSHR REQ, RESDNTL
- Open City violation record — CN070034 REPLACE D&H PORCH
Recently closed / other violations (sample)
- Closed / other
IR0055 PROTECT METAL MEMBERS
- Closed / other
NC3042 UNINTERRUPTED EXIT AT GRADE
- Closed / other
IR0000 SEND EX. METAL LETTER
Around 2764 N Lincoln Ave
- Lincoln Park building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 9:23 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.