Free building report
2720 N SHEFFIELD AVE
Winter habitability score Many open City violation records and/or complaint activity
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 2720 N Sheffield Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (29)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from February 1, 2023. All 29 are collapsed below — still open, still counted.
Show 29 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING /MOST APARTMENTS EXCEPT APT 412 - NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF SINK IN UNIT 217.
- Open
CN136026 — INSECTS
BUILDING -BED BUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
PARTIAL ENTRY GRANTED TO INTERIOR OF BUILDING BY MANAGER, UNIT 609 - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS AND ALL EXTERIOR ELEVATIONS. UNABLE TO VERIFY COMPLAINT OF MOLD/MILDEW AND LEAKS IN UNIT 609. (SEE COMMENTS).
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING- NOT REGISTERED FOR 2016.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR OF BUILDING - NO RESPONSE TO UNIT 1119 - UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED COMPLAINT OF BED BUG INFESTATION.
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
REPAIR MALFUNCTIONING DOOR RESTRICTOR ON #1 ELEVATOR. (PREVIOUSLY CITED).
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
REPAIR MALFUNCTIONING TWO WAY COMMUNICATION (PHONES) IN BOTH ELEVATORS.
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
FILLED OUT CODE DATA TAGS REQUIRED ON CONTROLLERS OR DISCONNECT SWITCHES FOR BOTH ELEVATORS (PREVIOUSLY CITED).
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
PROVIDE WORKING PIT LIGHTS FOR BOTH ELEVATORS(PREVIOUSLY CITED).
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED. BOTH ELEVATORS.(PREVIOUSLY CITED)
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
CLEAN BOTH ELEVATOR PITS AND CARTOPS.(PREVIOUSLY CITED).
- Open
EL0091 — NO PERMIT WIRING
1ST FLOOR THRU TOP FLOORS
- Open
EL0029 — EXPOSED WIRING
1ST FLOOR
- Open
EL0023 — INSTALL COVERS
1ST FLOOR
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
CLEAN ELEVATOR CARTOPS AND PITS. BOTH ELEVATORS.
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
FILLED OUT CODE DATA TAGS REQUIRED ON CONTROLLERS OR DISCONNECT SWITCHES. BOTH ELEVATORS.
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
MECHANICAL GUARDS REQUIRED ON MACHINE ROOM LIGHTING
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
PERFORM CATRGORY 1 TEST.TAG AND DOCUMENT AS REQUIRED. BOTH ELEVATORS.
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
REPAIR MALFUNCTIONING DOOR RESTRICTOR-ELEVATOR#1.
- Open
EV1110 — MAINTAIN OR REPAIR ELECT ELEVA
PROVIDE WORKING PIT LIGHTING. BOTH ELEVATORS.
- Open
NC6042 — SELF-CLOSE DOOR >4 STORY RES.
UNIT DOORS NOT CLOSING/ LATCHING PROPERLY; 1110, 1006, 902, 910, 916, 820, 817, 816, 813, 810, 804, 802, 803, 701, 702, 704, 706, 709, 714, 602, 603, 508, 516, 413, 414, 407, 310, 313, 316, 206.
- Open
CN197019 — INSTALL SMOKE DETECTORS
NO SMOKE DETECTOR IN MAINTENANCE ROOM.
- Open
CN197087 — CARB MONOX DETECT IN RESID
NO CO DETECTOR IN BOILER ROOM.
- Open
NC5042 — SELF-CLOSE CLASS B FIRE DOOR
BOILER ROOM DOOR TO CRAWL SPACE ON NORTH SIDE- DOOR BEING HELD OPEN. SOUTH CRAWL SPACE DOOR IN BOILER ROOM HAS NO CLOSER. CAPACTOR/ TRASH ROOM; ACCESS PANEL NOT RATED. 1ST FLOOR OUTER ELECTRIC ROOM ACCESS PANEL NOT RATED. 2ND FLOOR METER CLOSET- NO RATED PANEL; OPEN ELECTRIC CHASE. 10TH FLOOR ELECTRIC/ CABLE CLOSET DOOR NOT LATCHING.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY 304.
- Open
NC5012 — CLASS B DOOR IN STAIRWELL
STAIR DOORS NOT CLOSING/ LATCHING PROPERLY; 4N, 3N, 1S.
- Open
CN044013 — PIPE OPENING W/NONCOMBUST MATL
PENETRATIONS; ELEVATOR ROOM FLOOR, ELECTRIC/ CABLE CLOSETS ALL FLOORS, 11 METER CLOSET, 10TH FLR SOUTH END CEILING AT ELECTRICAL BOX, 9TH STORAGE ROOM OVER DOOR. 9TH STORAGE WITH OPENINGS AROUND DUCT. PENETRATIONS 9 SOUTH END CEILING ELECTRIC BOX, 7TH STORAGE ROOM, 7TH FLR METER CLOSET, 6TH FLR METER ROOM (AND OPEN MASONRY), 6 NORTH END CEILING ELECTRIC BOX, 5 NORTH END CEILING AT ELECTRIC BOX, 5TH FLOOR METER ROOM (AND OPENING IN MASONRY), 4RTH AND 3RD FLOOR METER ROOMS, OVER 317 IN CORRIDOR, 2, 3, AND 4 ELECTRIC BOXES NORTH AND SOUTH ENDS OF CORRIDORS, 2 FLR METER CLOSET. PENETRATIONS; 1ST FLOOR OUTER ELECTRIC ROOM, 1ST FLOOR INNER ELECTRIC ROOM, COMPACTOR/ TRASH ROOM, SWITCH ROOM, BOILER ROOM NORTH AND SOUTH SIDES INTO CRAWL SPACES, MAINTENANCE ROOM. EXPANDING FOAM NOT PERMITTED. REMOVE WHERE USED. SUBMIT DOCUMENTATION SHOWING FIRE STOPPING USE AND APPLICATION WAS COMPLETED IN ACCORDANCE WITH RECOGNIZED AGENCY STANDARDS.
- Open
NC4032 — 2-HR STAIR ENCLOSURE, 4+ STORY
ELEVATOR ROOM STAIRWELL WALL MISSING CMU TOWARD TOP; VOID, OPENING. 10N STAIR PENETRATION FILLED WITH EXPANDING FOAM. 7S EXPANDING FOAM AT CEILING. 2N STAIR WALL INTO CORRIDOR.
- Heat-related
CN046013 — UNAPPROVED HEATING DEVICE
APARTMENT 311 - TENANT USING KITCHEN OVEN FOR HEAT.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- building
Building Violation
- rodent
Rodent Baiting/Rat Complaint
- rodent
Rodent Baiting/Rat Complaint
- building
Building Violation
Timeline
- 311 building — Building Violation
- 311 rodent — Rodent Baiting/Rat Complaint
- 311 rodent — Rodent Baiting/Rat Complaint
- 311 building — Building Violation
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN136026 INSECTS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EL0023 INSTALL COVERS
- Open City violation record — EL0029 EXPOSED WIRING
- Open City violation record — EL0091 NO PERMIT WIRING
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Open City violation record — NC4032 2-HR STAIR ENCLOSURE, 4+ STORY
- Open City violation record — CN044013 PIPE OPENING W/NONCOMBUST MATL
- Open City violation record — NC5012 CLASS B DOOR IN STAIRWELL
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — NC5042 SELF-CLOSE CLASS B FIRE DOOR
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — NC6042 SELF-CLOSE DOOR >4 STORY RES.
- Open heat-related City violation record — CN046013 UNAPPROVED HEATING DEVICE
Recently closed / other violations (sample)
- Closed / other
BR1001 OWNER OR LICENSED CONTRACTOR
- Closed / other
BR3058 SEE INSPECTOR COMMENTS
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
RF301041 ARRANGE FOR INSPECTION
- Closed / other
CN136016 ROACHES
- Closed / other
CN194019 REPAIR OR REPLACE
- Closed / other
CN140016 DWELLING CLEAN AND SANITARY
- Closed / other
CN136016 ROACHES
- Closed / other
CN194019 REPAIR OR REPLACE
- Closed / other
CN140016 DWELLING CLEAN AND SANITARY
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
- Closed / other
BR1063 LEAKING BOILER TUBES
- Closed / other
BR1001 OWNER OR LICENSED CONTRACTOR
- Closed / other
EV1110 MAINTAIN OR REPAIR ELECT ELEVA
Around 2720 N Sheffield Ave
- Lincoln Park building violations and 311 complaints
- DePaul off-campus housing: Lakeview and Lincoln Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 8:13 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.