Free building report

2701 N CLARK ST

Winter habitability score Many open City violation records and/or complaint activity

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 2701 N Clark St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

69Open City violation records
1Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (69)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 18, 2017. All 69 are collapsed below — still open, still counted.

Show 69 older open City violation records (before November 2024)
  • Open

    CN064014 — REPAIR CORNICE

    SOUTH ELEVATION, CORNACE - OPEN MORTAR JOINTS.

  • Open

    CN021032 — DRVWAY/LOADING IN BLDG 3HR SEP

    1ST FLOOR GARAGE CEILING - MULTIPLE LOCATIONS MISSING FIRE RATED CEILING AND PROPER FIRE SEPARATION.

  • Open

    CN103025 — SUBMIT STRUCT. ENG. RPT (INT.)

    SUBMIT ENGINEERS REPORT. BASEMENT, EAST SIDE, UNDERSIDE OF GARAGE CONCRETE SLAB. SPALLED CONCRETE WITH EXPOSED REBAR. PLANS AND PERMIT REQUIRED FOR REPAIRS.

  • Open

    CN031023 — FIRE EXTNGSHR RECHARGE & TAG

    BASEMENT, FIRE EXTINGUISHERS - TAGS EXPIRED 1995.

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    BASEMENT, MARKED EXIT DOOR BLOCKED BY POLE AND JUNK.

  • Rodent-related

    CN134016 — RATS

    BASEMENT - MAJOR RAT INFESTATION. RAT DROPPING THROUGHOUT, STRONG SMELLS OF URINE, RAT HOLES IN BASEMENT, DEAD RATS IN BASEMENT.

  • Open

    CN107035 — MAINTAIN EXIT SIGN ILLUMINATED

    1ST FLOOR AND BASEMENT, NON-RESIDENTIAL UNIT - MULTIPLE EXIT SIGNS OUT.

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    1ST FLOOR, INTERIOR CEILING - WATER STAINED CEILING TILES THROUGHOUT, WITH SECTION OF CEILING IN REAR EAST HALLWAY SAGGING AND LOOSE.

  • Open

    CN104035 — MAINTAIN WINDOW

    SOUTH ELEVATION, 1ST FLOOR - SEALANT AROUND WINDOWS SEVERELY ROTTEN.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEVATION, 3RD FLOOR - FRACTURE IN BRICK WALL.

  • Open

    BR3058 — SEE INSPECTOR COMMENTS

    CARBON MONOXIDE DETECTOR.

  • Heat-related

    CN011012 — HEATING PLANT/BOILER ROOM DOOR

    BASEMENT BOILER ROOM DOOR OPEN AND NOT PROPER FIRE RATING AND CLOSURE .

  • Open

    CN104035 — MAINTAIN WINDOW

    WEST BASEMENT AREAWAY WINDOWS , RUSTED DETERIORATED WITH BROKEN GLASS .

  • Open

    NC4022 — 1-HR STAIR ENCLOSURE, HOTEL

    REAR BASEMENT STAIRWAY , WALLS AND CEILING PLASTER AND WALLBOARD MISSING DOWN TO WOOD WALL FRAMING .

  • Open

    EL0019 — DEFECTIVE FIXTURES

    BASEMENT THROUGHOUT ALL ROOMS , STAIRWAYS AND HALLWAYS , LIGHTING BROKEN , MISSING AND OUT OF SERVICE .

  • Open

    CN016012 — PROVIDE CLASS A FIRE DOOR

    CLASS A 3 HOUR FIRE DOOR ASSSEMBLY MISSING FROM BUILDING TO LOADING DOCK GARAGE AREA . PLANS AND PERMITS REQUIRED .

  • Open

    NC5062 — HOLDOPEN DEVICE, STAIR 3+ FLRS

    FRONT STAIRWAY AT SECOND AND THIRD FLOORS , REMOVE HOLD OPEN DEVICES .

  • Open

    NC5012 — CLASS B DOOR IN STAIRWELL

    FRONT STAIRWAY AT SECOND AND THIRD FLOORS , STAIRWAY DOORS NOT FIT IN FRAME OR FIRE RATED CLASS B . PROVIDE PERMIT FOR REPAIRS .

  • Open

    CN073054 — REPAIR EXTERIOR DOOR, RESET

    REAR FIRE ESCAPE DOORS AT SECOND AND THIRD FLOORS , RUSTED , HARD TO OPEN , SAGGING ,FIRE HAZARD TO OCCUPANTS . HARDWARE NOT WORKING PROPERLY .

  • Open

    CN136026 — INSECTS

    BUILDING -BEG BUG INFESTATION THROUGHOUT . PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT , BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION . BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION .

  • Open

    CN141016 — STOP SMOKE, NOXIOUS ODORS

    BASEMENT , NOXIOUS ODORS OF RATS AND RAT URINE . SECOND AND THIRD FLOORS SEVERE ODORS AND STENCH , UNSANITARY CONDITIONS .

  • Open

    CN140016 — DWELLING CLEAN AND SANITARY

    BUILDING - SEVERE UNSANITARY CONDITIONS , DIRTY STAINED WALLS , CEILING AND FLOORS IN FRONT STAIRWAY , HALLWAYS AND ROOMING UNITS .

  • Open

    CN133016 — CARPETING

    CARPETING IN FRONT STAIRWAY AND SECOND AND THIRD FLOORS , DIRTY , STAINED , WORN OUT WITH ODORS .

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    FIRST FLOOR COMMERCIAL SPACE , REAR HALLWAY , CONTACT LENS ROOM AND LENS PREP ROOM , CEILING WATER STAINED , GRID BUCKLED SAGGING , WALLS IN HALL STAINED WITH SEWAGE AND WATER BACKUP . ODORS OF SEWAGE AND UNSANITARY CONDITIONS .

  • Open

    CN017012 — INTERIOR FINISH FIRERESISTANCE

    SECOND AND THIRD FLOOR TOILET AND SHOWER ROOMS , GRID CEILING AND TILES NOT FIRE RATED . BUCKLED LOOSE , FALLING OUT AND WATER STAINED

  • Open

    PL166027 — PRV ADT BTHRM VENTIL TO OUTSDE

    SECOND AND THIRD FLOOR TOILET ROOMS AND SHOWER ROOM , VENTILATION NOT IN SERVICE .

  • Open

    PL159017 — REPLACE DEFECTIVE PLBG FIXTURE

    SECOND AND THIRD FLOOR SHOWER AND TOILET ROOMS , BROKEN SINKS , TOILETS , SHOWERS , TOILETS PARTITION AND DOORS

  • Open

    CN197079 — REPAIR/REPLACE SMOKE DETECTORS

    FRONT HALLWAYS , SECOND AND THIRD FLOOR HALLWAYS AND ROOMING UNITS , SMOKE DETECTORS , BROKEN , MISSING AND OUT OF SERVICE DATES , EXPIRED .

  • Open

    BR1001 — OWNER OR LICENSED CONTRACTOR

  • Open

    BR3058 — SEE INSPECTOR COMMENTS

    SMOKE ALARM.

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    BUILDING - POSTED OWNER'S I.D. SIGN INCOMPLETE INFORMATION , MISSING COMPLETE MAILING ADDRESS AND PHONE NUMBER .

  • Open

    CN064014 — REPAIR CORNICE

    SOUTH ELEVATION OPEN MORTAR JOINTS BETWEEN CORNICE LIMESTONES .

  • Open

    CN131026 — REPAIR SCREENS

    BUILDING - SECOND AND THIRD FLOORS ALL ELEVATIONS , TORN , LOOSE AND MISSING WINDOW SCREENS .

  • Rodent-related

    CN134066 — RAT PROOF EXTERIOR DOOR

    SOUTH LOADING DOCK DOOR OPEN AT BASE .

  • Open

    CN104025 — MAINTAIN WINDOW SASH

    REAR ELEVATION , SECOND AND THIRD FLOOR METAL WINDOW SASHES AND FRAMES RUSTED WITH FLAKING PAINT .

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    REAR FIRE ESCAPE AT THIRD FLOOR , TENANTS BELONGINGS STORED ON LANDINGS AND STAIRS .

  • Open

    CN072014 — SCRAPE/PAINT FIRE ESCAPE

    REAR FIRE ESCAPE AT THIRD FLOOR , GUARDRAILS LOOSE , BROKEN AND MISSING BOLTS .

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    STOREFRONT , OPEN MORTAR JOINTS AT LIMESTONES SURROUNDING DOORWAY . SPRAY PAINTED GRAFFITI . LOWER FOUNDATION STONES AT FRONT AND SOUTH SPALLED WITH OPEN MORTAR JOINTS . LIMESTONE FLOWER BOXES FRACTURED STONE WITH RUSTED IRON RAILS .

  • Open

    PL237058 — PRV DISCHARGE PIPE FROM PRV

    BASEMENT BOILER ROOM , WATER HEATER DISCHARGE PIPE SHORT , FOUR FEET FROM FLOOR .

  • Open

    PL161017 — REMV RARELY USED FIXTURE

    BASEMENT , REMOVE ABANDONED PLUMBING FIXTURES FROM TOILET ROOM , KITCHEN AND STORAGE ROOM SINK NEXT TO BOILER ROOM .

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    BASEMENT PILED WITH JUNK , DEBRIS , BUILDING MATERIALS ,SEVERE RAT HARBORAGE ALL ROOMS AND STORAGE AREAS .

  • Rodent-related

    CN134016 — RATS

    BASEMENT AND REAR LOADING DOCK , SEVERE RAT INFESTATION WITH LIVE AND DEAD RATS OBSERVED . BASEMENT FLOORS COVERED IN RAT DROPPINGS , FLOORING LOOKS LIKE IT'S COVERED IN GRAVEL . NOXIOUS ODORS AND STENCH OF RATS , RAT DROPPINGS AND URINE .

  • Open

    CN197088 — CARB MONOX DETECT IN HOTEL

    BASEMENT BOILER ROOM MISSING CARBON MONOXIDE DETECTOR .

  • Open

    CN031023 — FIRE EXTNGSHR RECHARGE & TAG

    BASEMENT FIRE EXTINGUISHERS TAGGED 1995 . SECOND AND THIRD FLOOR FIRE EXTINGUISHERS TAGGED 2014 .

  • Open

    CN021032 — DRVWAY/LOADING IN BLDG 3HR SEP

    SOUTH LOADING DOCK , EXPOSED WOOD CEILING JOIST , WALLS AND CEILING NOT FIRE RATED OR PROTECTED . SEVERE FIRE HAZARD TO TENANTS AND OCCUPANTS . PLANS AND PERMITS REQUIRED TO INSTALL PROPER FIRE RATED MATERIALS .

  • Open

    CN138066 — DEMO DEBRIS

    SOUTH LOADING DOCK STOCKPILED FLOOR TO CEILING WITH CONSTRUCTIONS MATERIALS AND DEBRIS . SEVERE FIRE HAZARD TO TENANTS , OCCUPANTS AND FIRST RESPONDERS .

  • Open

    CN107035 — MAINTAIN EXIT SIGN ILLUMINATED

    2ND AND 3RD FLOORS, - EMERGENCY EXIT SIGNS, MISSING OR NOT ILLUMINATED.

  • Open

    CN078014 — ILLUMINATE EXIT AREAS

    2ND FLOOR, - EMERGENCY LIGHTS NOT WORKING

  • Open

    CN107035 — MAINTAIN EXIT SIGN ILLUMINATED

    BASEMENT , REAR LOADING DOCK , 2ND AND 3RD FLOORS, - EMERGENCY EXIT SIGNS, MISSING OR NOT ILLUMINATED.

  • Open

    CN190029 — ARRANGE FOR REINSPECTION REGAR

    INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS OCCUPANCY AND CONDITIONS. AT THE TIME OF INSPECTION MANAGER NOT ON SITE, TEMANTS DENY ENTRY TO SRO, NO ENTRY TO THE REST OF THE BUILDING INCLUDING MECHANICAL ROOM.

  • Open

    EL0101 — OBTAIN PERMIT BEFORE SIGN WORK

    1 BLDG MOUNTED 20'X 14' VINYL SIGN READS: "CORONA EXTRA" 13-20-520 (NORTH ELEVATION)

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING-NOT REGISTERED FROM: 1990 THRU 2010.

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING-NOT REGISTERED FROM: 1990 THRU 2010.

  • Open

    CN196019 — NO POSTED ADDRESS

    BUILDING ADDRESSES-NOT POSTED.

  • Open

    CN194039 — REMOVE

    BRICKS SUPPORTING THE AIR CONDITIONER, ARE SET ON THE WINDOW SILL ABOVE THE PUBLIC WAY (SIDEWALK)(SEC.7-28-060).

  • Open

    CN196019 — NO POSTED ADDRESS

    BUILDING ADDRESSES-NOT POSTED.

  • Open

    CN194039 — REMOVE

    BRICKS SUPPORTING THE AIR CONDITIONER, ARE SET ON THE WINDOW SILL ABOVE THE PUBLIC WAY (SIDEWALK)(SEC.7-28-060).

  • Open

    CN073024 — REPAIR EXTERIOR DOOR FRAME

    OVERHEAD DOOR FRAME-ROTTED.

  • Open

    RF301051 — ARRANGE FOR RE-INSPECTION

  • Rodent-related

    CN136016 — ROACHES

    EXTERMINATE THE ROACHES UNIT 303 321

  • Rodent-related

    CN136016 — ROACHES

    EXTERMINATE THE ROACHES UNIT 303 321

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    SOUTH AT GRADE ROTTED VECHILE DOOR W/FRAME OPEN JOINTS AT GRADE, RAT ENTRY POINTS AT CORNERS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO RESPONSE AT DOOR BELL-UNVERIFIED COMPLAINT OF: SR#100247293-(#319)NO HEAT, ELECTRIC, DOOR LOCK REMOVED,REMOVED SMOKE DETECTORS OR CARBON MONOXIDE DETECTORS.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO RESPONSE AT DOOR BELL-UNVERIFIED COMPLAINT OF: SR#100247293-(#319)NO HEAT, ELECTRIC, DOOR LOCK REMOVED,REMOVED SMOKE DETECTORS OR CARBON MONOXIDE DETECTORS.

  • Rodent-related

    CN136016 — ROACHES

    EXTERMINATE THE ROACHES UNIT 303 321

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    PROVIDE FULL INT. ACCESS TO VERIFY SAFETY DET. AND PREVIOUSLY WRITTEN INT. VILOATIONS.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    EAST ELEV. SPOT TUCK POINT ERODED MORTAR JOINTS GRADE TO PARAPET

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    REPAIR WATER DAMAGED PLASTER CEILING AND SUSPENDED CEILINGS IN COMMUNITY TOILET ROOMS ON SECOND AND THIRD FLOORS

  • Open

    CN192019 — NOTIFY DOB, USE OF VACANT LND

    1ST FLOOR VACANT & SECURE

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  2. Open City violation record — CN104035 MAINTAIN WINDOW
  3. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  4. Open City violation record — CN107035 MAINTAIN EXIT SIGN ILLUMINATED
  5. Open City violation record — CN134016 RATS
  6. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
  7. Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
  8. Open City violation record — CN103025 SUBMIT STRUCT. ENG. RPT (INT.)
  9. Open City violation record — CN021032 DRVWAY/LOADING IN BLDG 3HR SEP
  10. Open City violation record — CN064014 REPAIR CORNICE
  11. Open City violation record — CN138066 DEMO DEBRIS
  12. Open City violation record — CN021032 DRVWAY/LOADING IN BLDG 3HR SEP
  13. Open City violation record — CN031023 FIRE EXTNGSHR RECHARGE & TAG
  14. Open City violation record — CN197088 CARB MONOX DETECT IN HOTEL
  15. Open City violation record — CN134016 RATS
  16. Open City violation record — CN138056 DEBRIS, EXCESSIVE
  17. Open City violation record — PL161017 REMV RARELY USED FIXTURE
  18. Open City violation record — PL237058 PRV DISCHARGE PIPE FROM PRV
  19. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  20. Open City violation record — CN072014 SCRAPE/PAINT FIRE ESCAPE
  21. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
  22. Open City violation record — CN104025 MAINTAIN WINDOW SASH
  23. Open City violation record — CN134066 RAT PROOF EXTERIOR DOOR
  24. Open City violation record — CN131026 REPAIR SCREENS
  25. Open City violation record — CN064014 REPAIR CORNICE
  26. Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
  27. Open City violation record — BR3058 SEE INSPECTOR COMMENTS
  28. Open City violation record — BR1001 OWNER OR LICENSED CONTRACTOR
  29. Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
  30. Open City violation record — PL159017 REPLACE DEFECTIVE PLBG FIXTURE
  31. Open City violation record — PL166027 PRV ADT BTHRM VENTIL TO OUTSDE
  32. Open City violation record — CN017012 INTERIOR FINISH FIRERESISTANCE
  33. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  34. Open City violation record — CN133016 CARPETING
  35. Open City violation record — CN140016 DWELLING CLEAN AND SANITARY
  36. Open City violation record — CN141016 STOP SMOKE, NOXIOUS ODORS
  37. Open City violation record — CN136026 INSECTS
  38. Open City violation record — CN073054 REPAIR EXTERIOR DOOR, RESET
  39. Open City violation record — NC5012 CLASS B DOOR IN STAIRWELL
  40. Open City violation record — NC5062 HOLDOPEN DEVICE, STAIR 3+ FLRS

Recently closed / other violations (sample)

  • Closed / other

    PL159017 REPLACE DEFECTIVE PLBG FIXTURE

  • Closed / other

    NC2011 PLANS & PERMITS REQ - CONTRCTR

  • Closed / other

    CN105025 REPAIR DOOR FRAME, MULLION

  • Closed / other

    CN011012 HEATING PLANT/BOILER ROOM DOOR

  • Closed / other

    NC4022 1-HR STAIR ENCLOSURE, HOTEL

  • Closed / other

    CN197088 CARB MONOX DETECT IN HOTEL

  • Closed / other

    CN133016 CARPETING

  • Closed / other

    NC5012 CLASS B DOOR IN STAIRWELL

  • Closed / other

    CN017012 INTERIOR FINISH FIRERESISTANCE

  • Closed / other

    CN107035 MAINTAIN EXIT SIGN ILLUMINATED

  • Closed / other

    CN104035 MAINTAIN WINDOW

  • Closed / other

    CN104025 MAINTAIN WINDOW SASH

  • Closed / other

    CN016012 PROVIDE CLASS A FIRE DOOR

  • Closed / other

    PL161017 REMV RARELY USED FIXTURE

  • Closed / other

    CN073054 REPAIR EXTERIOR DOOR, RESET

  • Closed / other

    CN101015 REPAIR INTERIOR WALLS/CEILING

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    CN194029 PROVIDE

  • Closed / other

    CN015062 OBSTRUCTIONS IN EXIT WAY

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN138056 DEBRIS, EXCESSIVE

  • Closed / other

    CN031023 FIRE EXTNGSHR RECHARGE & TAG

  • Closed / other

    CN021032 DRVWAY/LOADING IN BLDG 3HR SEP

  • Closed / other

    CN138066 DEMO DEBRIS

  • Closed / other

    CN011012 HEATING PLANT/BOILER ROOM DOOR

Around 2701 N Clark St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 6:49 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address