Free building report

2652 N Halsted St

Winter habitability score Open City violation records are on file — read the list, not just the score

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 2652 N Halsted St, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

9Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (9)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 27, 2011. All 9 are collapsed below — still open, still counted.

Show 9 older open City violation records (before November 2024)
  • Open

    CN070034 — REPLACE D&H PORCH

    REAR ENCLOSED PORCH FROM GROUND TO ROOF TOP (4 STORIES). STAIRS FROM 3 TO ROOF- NORTH STRINGER SUPPORTED BY CARGO STRAP, OTHER STRINGER TOE NAILED TO 4X4 AND SUPPORTED BY BLOCK/ SCABS AT NARROW END OF WEDGE/ WINDER TREADS. STRINGER AND TREAD CONNECTIONS AND CONSTRUCTION DANGEROUS AND HAZARDOUS TO ROOF. REAR PORCH WITH LOOSE RAILS. ENCLOSURE DANGEROUS AND HAZARDOUS WITH LOOSE FRAMING AND SIDING, AREAS WITH ROT. BEAMS TO 3RD FLOOR DECK TOE NAILED ONLY AT WEST WALL. OUT OF LEVEL TREADS, LOOSE TREADS. 2X4'S SUPPORTING STRINGERS AT VARIOUS LOCATIONS AGAINST ENCLOSURE AND ACHORED WITH NAILS ONLY, THESE 2X4'S SEATED ON BEAMS- TOE NAILED ONLY, AND ANCHORED TO LOOSE AND ROTTING SIDING. HORIZONTAL BEAMS ANCHORED WITH TOE'D NAILS AND LIGHT GAGE SIMPSON TIES. SCABBED COLUMNS AND STRINGERS AND BEAMS THROUGHOUT. STRINGERS SCABBED WITH PLYWOOD. PORCH WITH SCAB REPAIRS, ROTTING MATERIAL, AND IMPROPER CONNECTIONS/ SUPPORT. COMPLETE PLAN AND PERMIT REQUIRED.

  • Open

    CN197039 — RELOCATE SMOKE DETECTOR

    REAR PORCH SMOKE DETECTOR LOCATED OVER 2' OFF CEILING.

  • Open

    NC2021 — PERMIT REQUIRED - CONTRACTOR

    EXTERIOR WALL REPAIRS PERFORMED WITHOUT OBTAINING PERMIT.

  • Open

    NC4012 — 1-HR STAIR ENCLOSURE, <3 STORY

    REAR PORCH ENCLOSURE IS EXPOSED FRAMING AND WOOD SIDING. NO 1HR. FIRE RATING.

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    1ST AT REAR ENCLOSED PORCH RESTAURANT EXIT BLOCK WITH STORAGE

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    EAST AND SOUTH WALL WASHOUT MORTAR,REQUIRE PERMIT

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH RISERS VARIOUS IN HEIGHT,STRINGER OVER CUT,HORIZON RAILS,EXCESSIVE SPACING,REQUIRE PERMIT

  • Open

    CN197019 — INSTALL SMOKE DETECTORS

    REAR PORCH NO SMOKE DETECTOR

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH BROKEN TREADS,NO RISERS,WEAK RAILS,AND CRACK STRINGER,REQUIRE PERMIT

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — NC4012 1-HR STAIR ENCLOSURE, <3 STORY
  2. Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
  3. Open City violation record — CN197039 RELOCATE SMOKE DETECTOR
  4. Open City violation record — CN070034 REPLACE D&H PORCH
  5. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  6. Open City violation record — CN197019 INSTALL SMOKE DETECTORS
  7. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  8. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  9. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY

Recently closed / other violations (sample)

  • Closed / other

    CN134016 RATS

  • Closed / other

    CN190029 ARRANGE FOR REINSPECTION REGAR

  • Closed / other

    CN065024 MAINTAIN PROJECTIONS

  • Closed / other

    CN014012 NO CLOSET/STORAGE UNDER STAIR

  • Closed / other

    CN138056 DEBRIS, EXCESSIVE

  • Closed / other

    CN197019 INSTALL SMOKE DETECTORS

  • Closed / other

    CN065034 REPAIR WINDOW SILLS

  • Closed / other

    CN061014 REPAIR EXTERIOR WALL

  • Closed / other

    CN067024 REPAIR EAVES

Around 2652 N Halsted St

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 11:15 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com