Free building report

2612 W Augusta Blvd

Winter habitability score Multiple habitability signals in public records

Download a PDF of this report

Renter reviews

Firsthand and anonymous. Renter opinions are separate from the city records below.

No renter reviews here yet. If you’ve lived at 2612 W Augusta Blvd, yours could be the first.

A Chicago three-flat

Do you live here?

One tap helps other renters. The full building record stays right below.

Sure, I’ll share
How’s it been living here? Required

Tap a star — 1 is rough, 5 is great.

Add more detail (optional — heat, pests, repairs, noise, management)

Tap 1 to 5 for any you want. 1 is rough, 5 is great. Skip the rest.

Heat Warm enough when it counts?
Pests Have pests been a problem?
Maintenance responsiveness When something broke, how fast did it get fixed?
Noise How noisy was it, day to day?
Management How they treated you and answered you
Would you rent here again?

Your own experience only — no fake or paid reviews. Shown anonymously after you confirm and a person approves it. Review policy · Terms

37Open City violation records
0Open heat-related City records
0311 rodent (24 mo)
0311 building (24 mo)

What rat complaints mean →

All open City violation records (37)

No open City violation records dated in the last 24 months (since November 2024). The newest open one is from May 30, 2017. All 37 are collapsed below — still open, still counted.

Show 37 older open City violation records (before November 2024)
  • Open

    RF301041 — ARRANGE FOR INSPECTION

    CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS ,WEDNESDAYS BETWEEN 8:00 AND 9:00 AM.

  • Open

    RF301031 — ACCESS TO ROOF

    ROOF

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    NORTH ELEVATION/REAR EXTERIOR PORCH-MISSING VEHICAL IMPACK PROTECTION BALLARDS AT COLUMNS.

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    BUILDING - OWNER'S ID SIGN INCOMPLETE, MISSING MAILING ADDRESS.

  • Open

    CN061014 — REPAIR EXTERIOR WALL

    SOUTH ELEVATION - BULGING AND SHIFTING BRICKS OFF OF LINTELS.

  • Open

    CN065034 — REPAIR WINDOW SILLS

    WEST ELEVATION WINDOW SILLS - WASHED OUT MORTAR.

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    WEST ENTRY DOOR - BROKEN DOOR AT HANDLE.

  • Open

    CN065014 — REPAIR LINTELS

    SOUTH ELEVATION 3RD FLOOR - LINTELS HAVE FAILED, SAGGING AND WRAPPED IN METAL. PERMIT REQUIRED FOR REPAIRS TO LINTELS AND WALL.

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    INTERIOR OF BUILDING - TENANTS WOULD NOT GRANT ACCESS TO CONDUCT INTERIOR INSPECTION. UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY.

  • Open

    PL153017 — REPLACE DEFECTIVE FAUCET

    MISSING HANDLE ON TUB FAUCET 2ND REAR APARTMENT

  • Open

    CN190019 — ARRANGE PREMISE INSPECTION

    NO ENTRY 1ST FLOOR FRONT AND REAR ALSO 3RD FLOOR REAR (VACANT) BASEMENT AREA

  • Open

    EL0019 — DEFECTIVE FIXTURES

    REPLACE DEFECTIVE LIGHT FIXTURES ON EXTERIOR AND IN APARTMENT 2R BEDROOMS KITCHEN

  • Open

    EL0023 — INSTALL COVERS

    INSTALL COVERS ON OUTLETS & SWITCHES REAR

  • Open

    EL0024 — INSTALL ILLUMINATION

    ILLUMINATE REAR PORCH AREA

  • Open

    CN066034 — REPAIR BALCONY

    FRONT BALCONIES (3) BRICKWORK. FROM GRADE TO 3RD LEVEL IS DISPLACED / SHIFTED - MORTAR EROSION HAS ALLOWED FOR CONTINUOUS RAIN WATER PENETRATION TO DEGRADE MASONRY INTEGRITY THIS BRICK WORK WILL BECOME MORE LOOSE AND DETACHED AS TIME - WEATHER CONTINUE TO DE-GRAVE THIS MASONRY OVER PUBLIC WAY AND MAIN BUILDING ENTRANCE UNSAFE CONDITION

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR PORCH 3 LEVELS SIGNS OF WOOD ROT AT BEAM - COLUMN JOINTS ALSO SEVERELY RUSTED NAILS AT ALL CRITICAL BEAM - COLUMN CONNECTIONS NO BOLTS AT ANY CRITICAL CONNECTION (NEWEL POSTS, BANISTERS, UPPER CASES) PORCH BANISTERS DEFECT UNDER LOAD

  • Open

    CN015062 — OBSTRUCTIONS IN EXIT WAY

    ALL DWELLING UNITS HAVE PADLOCKED BURGLAR GATES THAT OBSTRUCT EGRESS. ALSO, AT 2ND FLOOR REAR THE BACK DOOR IS BARRICADE. UNSAFE CONDITION

  • Rodent-related

    CN134016 — RATS

    BUILDING IS RAT INFESTED

  • Open

    CN073044 — REPAIR EXTERIOR DOOR HARDWARE

    BACK DOOR AT 2ND REAR APARTMENT HAS NO LOCK HARDWARE NO SECURITY TENANTS HAVE BARRICADE REAR DOOR

  • Open

    CN140016 — DWELLING CLEAN AND SANITARY

    INTERIOR OF THIS BUILDING (STAIRWELLS OCCUPIED AND VACANT APARTMENTS) GENERALLY IN FILTHY CONDITION

  • Open

    CN197087 — CARB MONOX DETECT IN RESID

    ALL UNITS AND BASEMENT NO CARBON MONOXIDE DETECTORS

  • Open

    CN073014 — REPAIR EXTERIOR DOOR

    FRONT DOOR (AT LOBBY) MISSING GLASS PANEL

  • Open

    CN103015 — REPAIR FLOOR

    2ND REAR KITCHEN FLOOR TILES MISSING

  • Open

    CN101015 — REPAIR INTERIOR WALLS/CEILING

    2ND REAR MOLD ON BATHROOM WALLS

  • Open

    PL238010 — REPAIR DEFECTIVE DOWNSPOUT

    NO GUTTER OR DOWN SPOUT IN REAR OF BUILDING

  • Open

    PL157047 — STOP LEAKING WATER

    STOP LEAK ON TUB FAUCET 2ND FLOOR REAR APARTMENT

  • Open

    PL153017 — REPLACE DEFECTIVE FAUCET

    MISSING FLUSH HANDLE ON TUB FAUCET 2ND REAR APARTMENT

  • Open

    PL153027 — REPLACE DEFECTIVE FLUSH DEVICE

    RUNNING TOILET 2ND REAR

  • Rodent-related

    CN134026 — RAT STOP AROUND EXTERIOR

    REAR YARD RAT HOLES

  • Open

    CN070024 — REPAIR PORCH SYSTEM

    REAR OPEN PORCH VISIBLE FROM YARD WEAK & MISSING PICKETS, GUARDRAILS IMPROPER, 4X4'S MISSING IMPROPER FOOTINGS - PORCH AREAS THRU-OUT MISSING BOLTS STRAPS, ANGLE IRON & HANGERS WHERE NEEDED - PLANS & PERMIT REQUIRED FOR REPAIRS ON REAR

  • Open

    CN137056 — STOP STORING GARBAGE

    REAR YARD GARBAGE CANS RELOCATE PROBLEMS WITH RATS

  • Open

    CN138106 — STOP/REMOVE NUISANCE

    REAR YARD JUNK & DEBRIS

  • Open

    CN198019 — FILE BLDG REGISTRATION

    BUILDING REGISTRATION FOR ALL YEARS 1999-2006

  • Open

    CN196029 — POST OWNER/MANAGERS NAME/#

    BUILDING FRONT POST OWNER SIGN

  • Open

    CN138056 — DEBRIS, EXCESSIVE

    REAR YARD JUNK & DEBRIS

  • Rodent-related

    CN134036 — RAT PROOF OPENINGS

    REAR YARD RAT PROOF - PORCH AREA INFESTED

  • Open

    CN075014 — GRADE AND DRAIN LOT

    REAR YARD HOLES & RUTS

About these City violation records

From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”

↑ Back to renter reviews

311 complaints (24 months)

No matching 311 complaints in the last 24 months.

Timeline

  1. Open City violation record — RF301031 ACCESS TO ROOF
  2. Open City violation record — RF301041 ARRANGE FOR INSPECTION
  3. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  4. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  5. Open City violation record — CN065014 REPAIR LINTELS
  6. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  7. Open City violation record — CN065034 REPAIR WINDOW SILLS
  8. Open City violation record — CN061014 REPAIR EXTERIOR WALL
  9. Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
  10. Open City violation record — PL153027 REPLACE DEFECTIVE FLUSH DEVICE
  11. Open City violation record — PL153017 REPLACE DEFECTIVE FAUCET
  12. Open City violation record — PL157047 STOP LEAKING WATER
  13. Open City violation record — PL238010 REPAIR DEFECTIVE DOWNSPOUT
  14. Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
  15. Open City violation record — CN103015 REPAIR FLOOR
  16. Open City violation record — CN073014 REPAIR EXTERIOR DOOR
  17. Open City violation record — CN197087 CARB MONOX DETECT IN RESID
  18. Open City violation record — CN140016 DWELLING CLEAN AND SANITARY
  19. Open City violation record — CN073044 REPAIR EXTERIOR DOOR HARDWARE
  20. Open City violation record — CN134016 RATS
  21. Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
  22. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  23. Open City violation record — CN066034 REPAIR BALCONY
  24. Open City violation record — EL0024 INSTALL ILLUMINATION
  25. Open City violation record — EL0023 INSTALL COVERS
  26. Open City violation record — EL0019 DEFECTIVE FIXTURES
  27. Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
  28. Open City violation record — PL153017 REPLACE DEFECTIVE FAUCET
  29. Open City violation record — CN075014 GRADE AND DRAIN LOT
  30. Open City violation record — CN134036 RAT PROOF OPENINGS
  31. Open City violation record — CN138056 DEBRIS, EXCESSIVE
  32. Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
  33. Open City violation record — CN198019 FILE BLDG REGISTRATION
  34. Open City violation record — CN138106 STOP/REMOVE NUISANCE
  35. Open City violation record — CN137056 STOP STORING GARBAGE
  36. Open City violation record — CN070024 REPAIR PORCH SYSTEM
  37. Open City violation record — CN134026 RAT STOP AROUND EXTERIOR

Recently closed / other violations (sample)

  • Closed / other

    CN070014 REPAIR EXTERIOR STAIR

  • Closed / other

    CN131016 SCREEN OUTER DOORS, WINDOWS

  • Closed / other

    CN138026 USE SANITARY REFUSE CONTAINERS

  • Closed / other

    CN074014 SERVICE WALK, PASSAGE, AREAWAY

  • Closed / other

    EL0020 SUPPORT FIXTURES

  • Closed / other

    CN070024 REPAIR PORCH SYSTEM

Around 2612 W Augusta Blvd

Nearby buildings with open City violation records

Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.

How the winter score is calculated
  1. Start at 100 (better = higher).
  2. Minus up to 40 for open heat/boiler-related building violations (12 pts each).
  3. Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
  4. Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
  5. Minus up to 15 for recent 311 building complaints (2 pts each).
  6. Extra −10 if 3+ open heat-related violations.
  7. Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
  8. Public records only — not an inspection, appraisal, or legal advice.

Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 7:32 AM CT.

ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.

“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.

Check another address

Help: hello@scoutmybuilding.com