All open City violation records (17)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from January 4, 2013. All 17 are collapsed below — still open, still counted.
Show 17 older open City violation records (before November 2024)
- Open
CN079014 — REPAIR/REBUILD GARAGE OR SHED
REAR GARAGE - DILAPITATED ROOFING AND SIDING - BROKEN , LOOSE , AND MISSING SECTIONS. WALLS - LOOSE AND LEANING - WEAK. OVERHEAD DOOR HEADER - SAGGING. OVERHEAD DOOR BROKEN.
- Open
CN065014 — REPAIR LINTELS
NORTH - LINTELS RUSTED AND SAGGING - PERMIT REQUIRED FOR LINTEL REPLACEMENT.
- Open
CN104035 — MAINTAIN WINDOW
SOUTH , EAST , AND WEST WINDOW FRAMES - ROTTED WITH PEELING PAINT.
- Open
CN104025 — MAINTAIN WINDOW SASH
EAST , WEST , AND SOUTH - WINDOW SASHES - ROTTED WITH PEELING PAINT.
- Open
CN104055 — REPUTTY WINDOW PANES
SOUTH , EAST , AND WEST - WINDOWS WITH BROKEN AND MISSING PUTTY.
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
SOUTH WINDOWS AT 2ND - BROKEN AND MISSING PANES. SOUTHEAST BASEMENT WINDOW - CRACKED PANE.
- Open
CN062024 — PARAPET
NORTHWEST PARAPET - WASHED OUT MORTAR WITH MISSING AND SPALLING BRICKS.
- Open
CN074014 — SERVICE WALK, PASSAGE, AREAWAY
SOUTHEAST SERVICE WALK - BUCKLED , TIPPED , AND BROKEN CONCRETE.
- Open
CN069034 — REPAIR AREAWAY WALL
NORTH BASEMENT RETAINING WALL - BROKEN AND FRACTURED CONCRETE.
- Open
CN198019 — FILE BLDG REGISTRATION
BUILDING NOT REGISTERED FROM 2005 THROUGH 2013.
- Open
CN061014 — REPAIR EXTERIOR WALL
WEST WALL AT 2ND UNDER WINDOWS - STEP FRACTURES WITH WASHED OUT MORTAR AND SPALLING BRICKS. EAST WALL - WASHED OUT MORTAR WITH SPALLING BRICKS.
- Open
CN074024 — PROVIDE GUARD RAIL 42 IN HIGH
NORTH AND EAST BASEMENT STAIRWAYS - GRADE TO BASEMENT AT GRADE - GUARDRAILS MISSING.
- Open
CN066034 — REPAIR BALCONY
EAST BALCONIES - UNDERSIZED 2 X 6 DECK JOISTS SPAN 9'. LEDGER BOARDS ONLY NAILED TO BUILDING. DECKING - ROTTED. GUARDRAILS - LOOSE AND ONLY 38'' HIGH. PERMIT ONLY REQUIRED FOR REPAIRS.
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
SOUTH EXIT DOOR BLOCKED WITH A 4' X 8 ' SHEET OF PLYWOOD - HAMPERING EGRESS.
- Open
CN197019 — INSTALL SMOKE DETECTORS
BASEMENT UTILITY ROOM - SMOKE DETECTOR - MISSING.
- Open
CN197087 — CARB MONOX DETECT IN RESID
BASEMENT UTILITY ROOM - CARBON MONOXIDE DETECTOR - MISSING.
- Open
CN105055 — INSTALL DOOR VIEWING DEVICE
EAST INTERIOR STAIRWAY APARTMENT ENTRY DOORS - BASEMENT THROUGH 2ND - VIEWING DEVICES - MISSING.
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
- rodent
Rodent Baiting/Rat Complaint
Timeline
- 311 rodent — Rodent Baiting/Rat Complaint
- Open City violation record — CN105055 INSTALL DOOR VIEWING DEVICE
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN066034 REPAIR BALCONY
- Open City violation record — CN074024 PROVIDE GUARD RAIL 42 IN HIGH
- Open City violation record — CN061014 REPAIR EXTERIOR WALL
- Open City violation record — CN198019 FILE BLDG REGISTRATION
- Open City violation record — CN069034 REPAIR AREAWAY WALL
- Open City violation record — CN074014 SERVICE WALK, PASSAGE, AREAWAY
- Open City violation record — CN062024 PARAPET
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN104055 REPUTTY WINDOW PANES
- Open City violation record — CN104025 MAINTAIN WINDOW SASH
- Open City violation record — CN104035 MAINTAIN WINDOW
- Open City violation record — CN065014 REPAIR LINTELS
- Open City violation record — CN079014 REPAIR/REBUILD GARAGE OR SHED
Recently closed / other violations (sample)
- Closed / other
CN063014 CHIMNEY
- Closed / other
CN138056 DEBRIS, EXCESSIVE
- Closed / other
CN040053 FLAM LIQ TANK FRONTAGE CONSENT
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
Around 2247 W Thomas St
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 7:56 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.