2007 W Birchwood Ave
Winter habitability score Many open City violation records and/or complaint activity
Renter reviews
Firsthand and anonymous. Renter opinions are separate from the city records below.
No renter reviews here yet. If you’ve lived at 2007 W Birchwood Ave, yours could be the first.
Do you live here?
One tap helps other renters. The full building record stays right below.
Thanks for looking. The full record is right below.
No problem. The full record is right below.
Thanks, neighbor. Share how it’s really been — one tap on the stars is all it takes.
Thanks. Share how it really was — one tap on the stars is all it takes.
Sure, I’ll share
All open City violation records (37)
No open City violation records dated in the last 24 months (since November 2024). The newest open one is from November 19, 2015. All 37 are collapsed below — still open, still counted.
Show 37 older open City violation records (before November 2024)
- Open
CN193110 — VACANT BUILDING - REGISTER
- Open
CN197087 — CARB MONOX DETECT IN RESID
APARTMENT 1 AND BASEMENT - MISSING CARBON MONOXIDE DETECTOR.
- Heat-related
CN132016 — HEAT UNIT ADEQUATELY
APARTMENT 1 - 49 DEGREES.APARTMENT 3 - 54 DEGREES.
- Open
CN197019 — INSTALL SMOKE DETECTORS
APARTMENT 1 AND BASEMENT - MISSING SMOKE DETECTORS.
- Open
CN132046 — SAFE WORKING CONDITIONS
BOILER - NOT WORKING AT TIME OF INSPECTION.
- Open
CN132046 — SAFE WORKING CONDITIONS
2ND FLOOR APT. - ONLY ONE RADIATOR OF 4 ARE WARM.
- Open
BR3057 — INSTALL
CARBON MONOXIDE DETECTOR IN BOILER ROOM.
- Open
BR1001 — OWNER OR LICENSED CONTRACTOR
- Open
CN070034 — REPLACE D&H PORCH
REAR 3 STORY PORCH DANGEROUS AND HAZARDOUS CONDITIONS. SEVERE ROT. ROTTING JOISTS, POSTS, RAILS, BEAMS, DECKS. DEFLECTION AT STAIRS AND EACH FLOOR. JOISTS, BEAMS, COLUMNS, STRINGERS, POSTS, RAILS, ALL MEMBERS ANCHORED/ FASTENED WITH NAILS ONLY. LOOSE AND DEFLECTING RAILS. SYSTEM IS SEVERELY PITCHED. PORCH WITH A PORTION ENCLOSED. ENCLOSURE REDUCES DECK EGRESS TO 22'' DEPTH AT EACH FLOOR. WORN TREADS. SPLIT/ CRACKED STRINGERS. OBTAIN COMPLETE PLAN AND PERMIT FOR REPLACEMENT OF PORCH.
- Open
CN132046 — SAFE WORKING CONDITIONS
BOILER NOT OPERATIONAL. BOILER NOT GENERATING HEAT.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
SMOKE DETECTORS OUT OF SERVICE- TOP OF FRONT STAIR SYSTEM.
- Open
CN197087 — CARB MONOX DETECT IN RESID
BASEMENT BOILER ROOM AND ILLEGAL BASEMENT APARTMENT- CARBON MONOXIDE DETECTOR NOT IN SERVICE.
- Open
CN197019 — INSTALL SMOKE DETECTORS
BASEMENT BOILER ROOM NO SMOKE DETECTOR.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
REAR PORCH WITH ENCLOSED PORTION- ALTRERED INTO KITCHEN AREAS. NO PLAN AND PERMITS ON FILE.
- Open
NC3012 — INSUFFICIENT MEANS OF EGRESS
AT REAR PORCHES- ENCLOSED PORTION REDUCES EGRESS AREA AT EACH FLOOR DOWN TO 22''.
- Open
PL159057 — STOP ODORS RPR DFT SEWAGE SYS
BASEMENT- STRONG SEWER ODORS, STANDING WATER, VISIBLE WASTE.
- Open
CN079024 — REPAIR / REBUILD SHED
GARAGE- ROTTING SIDING, ROTTING FASCIA.
- Open
CN140026 — UNSANITARY CONDITIONS-ANIMALS
REAR YARD- DOG WASTE THROUGHOUT.
- Open
EL0018 — DEFECTIVE OUTLETS
3RD FLOOR APARTMENT EAST WALL ELECTRICAL OUTLETS THROUGHOUT NOT OPERATING.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
BASEMENT ILLEGAL APARTMENT. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE BUILDING TO ORIGINAL CONDITION. PERMIT IS REQUIRED FOR DECONVERSION AS WELL.
- Open
CN110105 — LIGHT AND VENT
ILLEGAL BASEMENT APARTMENT- INSUFFICIENT LIGHT AND VENTILLATION- 2 GLASS BLOCK WINDOWS EACH WITH ONE 15'' X 7'' VENT.
- Heat-related
NC10022 — HEATING PLANT SEPARATION
ILLEGAL BASEMENT APARTMENT WITH WALL SHARED WITH BOILER ROOM. BOILER ROOM SIDE OF WALL IS SHEETED WITH WOOD PANELING, NO ONE HOUR FIRE SEPARATION AS REQUIRED. DOOR TO BASEMENT ILLEGAL APARTMENT IS HOLLOW CORE DOOR WITH NO FIRE RATING.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY,TO APT.3RD: NO ADULTS AT HOME, MINORS ONLY.UNABLE TO VERIFY COMPLAINT OF BEDBUGS.
- Open
CN197019 — INSTALL SMOKE DETECTORS
NO SMOKE DETECTORS UNITS 2 AND 3.
- Open
CN197079 — REPAIR/REPLACE SMOKE DETECTORS
SMOKE DETECTOR NOT OPERATING TOP OF FRONT STAIRS.
- Open
PL154027 — SUPPLY HOT WTR MIN TEMP 120DEG
NO HOT WATER. UNIT 2 HOT WATER TAP TEMPERATURE IS 68 DEGREES. UNIT 3 HOT WATER TAP TEMPERATURE IS 68 DEGREES.
- Open
CN070024 — REPAIR PORCH SYSTEM
1. WOOD ROTTED THRU - OUT.2. 6X6 COLUMNS RESTING ON CONCRETE BLOCKS SET IN CONCRETE SLAB.3. FOUNDATION STATUS UNKNOWN.4. LOOKOUT BEAMS OVER SPANNED.5. INADEQUATE BEAM TO COLUMN CONNECTION.6. STRINGERS INADEQUATELY SUPPORTED.7. STAIRTREADS TOO SMALL.8. JOIST INADEQUATELY SUPPORTED.9. GUARDRAILS TOO LOW WITH HORIZONTAL PICKETS.10. PLANS AND PERMIT REQUIRED.
- Open
CN015062 — OBSTRUCTIONS IN EXIT WAY
WILL NOT OPEN, STUCK SHUT. NEEDS TO BE RE-HUNG.
- Open
NC3012 — INSUFFICIENT MEANS OF EGRESS
LANDING'S AT FLOOR LEVELS UNDER 30 INCHES OF CLEAR TRAVEL WIDTH.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
NO PLANS OR PERMIT ON FILE FOR 12 FOOT BY 18 FOOT DECK BUILT IN BACK YARD.
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
NO PLANS OR PERMIT ON FILE TO ENCLOSE PORTION OF REAR PORCH.
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
HOLE IN WALL AT 1ST FLOOR.
- Open
CN196019 — NO POSTED ADDRESS
FRONT ADDRESS NOT VISIBLE
- Open
CN190019 — ARRANGE PREMISE INSPECTION
INTERIOR NO ENTRY NO RESPONSE
- Open
CN104015 — REPLCE WINDOW PANES, PLEXGLAS
REAR 2ND FLOOR WINDOW BROKEN PANE
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
OBTAIN PERMIT FOR REAR 10 FOOT HIGH FENCE
- Open
CN196029 — POST OWNER/MANAGERS NAME/#
FRONT MANAGEMENT SIGN NO MAILER ADDRESS
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN193110 VACANT BUILDING - REGISTER
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open heat-related City violation record — CN132016 HEAT UNIT ADEQUATELY
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- Open City violation record — BR1001 OWNER OR LICENSED CONTRACTOR
- Open City violation record — BR3057 INSTALL
- Open heat-related City violation record — NC10022 HEATING PLANT SEPARATION
- Open City violation record — CN110105 LIGHT AND VENT
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — EL0018 DEFECTIVE OUTLETS
- Open City violation record — CN140026 UNSANITARY CONDITIONS-ANIMALS
- Open City violation record — CN079024 REPAIR / REBUILD SHED
- Open City violation record — PL159057 STOP ODORS RPR DFT SEWAGE SYS
- Open City violation record — NC3012 INSUFFICIENT MEANS OF EGRESS
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN197087 CARB MONOX DETECT IN RESID
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN132046 SAFE WORKING CONDITIONS
- Open City violation record — CN070034 REPLACE D&H PORCH
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — PL154027 SUPPLY HOT WTR MIN TEMP 120DEG
- Open City violation record — CN197079 REPAIR/REPLACE SMOKE DETECTORS
- Open City violation record — CN197019 INSTALL SMOKE DETECTORS
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — NC3012 INSUFFICIENT MEANS OF EGRESS
- Open City violation record — CN015062 OBSTRUCTIONS IN EXIT WAY
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — CN196029 POST OWNER/MANAGERS NAME/#
- Open City violation record — NC2021 PERMIT REQUIRED - CONTRACTOR
- Open City violation record — CN104015 REPLCE WINDOW PANES, PLEXGLAS
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN196019 NO POSTED ADDRESS
Recently closed / other violations (sample)
- Closed / other
VT1010 ARRANGE COMPLETED PERMIT INSP.
Around 2007 W Birchwood Ave
- Rogers Park building violations and 311 complaints
- Loyola Chicago off-campus housing: Rogers Park renter guide
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 21, 2026 at 10:58 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.