All open City violation records (47)
1 of 47 open City violation records are from the last 24 months (since November 2024), shown newest first. 46 older ones are collapsed below — still open, still counted.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO GAIN INTERIOR ACCESS FOR ANNUAL INSPECTION 2026. 14A-1-104.7
Show 46 older open City violation records (before November 2024)
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ENTRY
- Open
CN190019 — ARRANGE PREMISE INSPECTION
UNABLE TO GAIN ACCESS FOR 2021 ANNUAL INSPECTION
- Open
EL1805 — DEFECTIVE DISTRIBUTION
LOOSE DAMAGED COVER 2ND FLOOR PANEL. INSURE DISTRIBUTION IN APPROVED CONDITION THROUGHOUT. DANGEROUS AND HAZARDOUS
- Open
EL1801 — DEFECTIVE SERVICE
SERVICE CABLES APPERA DETERIORATED / DAMAGED AT SERVICE HEAD. MAIN DISCONNECTS NOT GROUPED. ENSURE SERVICE IN APPROVED CONDITION. DANGEROUS AND HAZARDOUS
- Open
CN103035 — STRUCTURAL MEMBER, PIER BLOCK
MAIN SUPPORT BEAM FOR PROPERTY SEVERELY ROTTED AT MID POINT, CURRENTLY BEING SUPPORTED BY TEMPORARY SCREW JACK POST. REPAIRS REQUIRED. MULTIPLE JOIST FOR 1ST FLOOR HAS HAS BEEN ALTERED AND IMPROPERLY RECONSTRUCTED 14X-3-303.1.1 DANGEROUS AND HAZARDOUS
- Open
CN116025 — LOAD BEARING ARCH. REPORT
STRUCTURAL ENGINEER'S REPORT REQUIRED TO DETERMINE ANY AND ALL MEANS OF CORRECTING STRUCTURAL MEMBERS THROUGHOUT BASEMENT AREAS 14A-8-803.1
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
PLANS AND PERMITS REQUIRED FOR CORRECTION OF ALL BUILDING CODE VIOLATIONS AND ALL STRUCTURAL REPAIRS TO BE CONDUCTED AT PROPERTY 14A-4-401.1
- Open
EL1884 — SEE INSPECTOR COMMENTS
LIGHT FIXTURES, BOXES, FITTINGS, RACEWAYS AT WALKIN COOLER MUST BE SUITABLE FOR WET LOCATION AND IDENTIFIED FOR USE. 14E-1-110.3 DANGEROUS AND HAZARDOUS
- Open
CN012022 — 1HR FLR OVER BSMT, 1 OR 2 DU
FLOOR OVER BASEMENT REQUIRES 1HOUR FIRE SEPARATION MATERIALS CURRENTLY CEILINGS THROUGHOUT BASEMENT LACKS ANY SORT OF FIRE RESISTANT MATERIALS AT CEILING THROUGHOUT 14X-5-502.3
- Heat-related
CN011012 — HEATING PLANT/BOILER ROOM DOOR
FIRE DOOR FOR FURNACE ROOM LOCATED AT BASEMENT CUT AND ALTERED COMPROMISING DOORS' FIRE RESISTANT INTEGRITY DANGEROUS AND HAZARDOUS 14B-7-716
- Heat-related
CN010012 — 1-HR HEATING PLANT ENCLOSURE
MECHANICAL ROOM LOCATED WITHIN THE BASEMENT AREAS CURRENTLY HAS OPEN STUD WALLS FAILING TO MEET 1HOUR MINIMUM FIRE SEPARATION REQUIREMENTS DANGEROUS AND HAZARDOUS 14B-5-509
- Open
NC2071 — WORK NOT ALLOWED
FENCE PERMIT REQUIRED FOR FENCE TYPE AND FENCE BEING OVER 5 FEET AT REAR OF PROPERTY. CURRENTLY MASONRY FENCE CONSTRUCTED AT REAR OF PROPERTY. 14A-4-404.7
- Open
CN070024 — REPAIR PORCH SYSTEM
REAR OF PROPERTY 2 STEP PORCH SYSTEM WITH LANDING ROTTED PLYWOOD AT ENTRYWAY UPON ENTERING PROPERTY. REPAIRS REQUIRED 14X-3-303.1.1
- Open
PL239010 — ENGAG LIC & BOND PLMBNG CNTRC
ENGAGE LICENSED AND BONDED PLUMBING CONTRACTOR TO INSTALL PLUMBING.
- Open
PL232011 — OBTAIN PERMIT FOR PLUMBING
OBTAIN PERMIT BEFORS CONSTRUCTING, ALTERING, OR USING PLUMBING SYSTEM.
- Open
PL237004 — INDIRECT CONN.FOR WATER SUPPLY
BOILER, SODA MACHINE, AND ICE MACHINE WATER SUPPLIES ARE ALL DIRECTLY CONNECTED TO POTABLE WATER SYSTEM WITHOUT ANY MEANS OF CROSS CONTAMINATION PROTECTION DANGEROUS AND HAZARDOUS
- Open
PL234002 — SOIL/WASTE,VENT PIPE MATRL
UNAPPROVED RUBBER COUPLINGS AND FITTINGS TO DRAIN WASTE AND VENT PIPING THROUGHOUT BASEMENT
- Open
PL163027 — PROVIDE OPEN FRONT TOILET SEAT
UNAPPROVED ROUND BOWL TOILETS WITH CLOSED FRONT SEATS IN ALL BATHROOMS
- Open
PL194029 — PROVIDE
NO MIXING VALVE TO LAVATORIES IN ALL BATHROOMS 18-29-607
- Open
EL1886 — Violation
PROVIDE ANY REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES, EQUIPMENT AT 1ST FLOOR, 2ND FLOOR, AND BASEMENT. 2ND FLOOR CONVERTED INTO A PARTY ROOM. MISCELLANEOUS MODIFICATIONS 1ST FLOOR AND BASEMENT, SERVICE MODIFIED 14A-5-505.2 INSUFFICIENT PERMITS, NO PERMITS, NO INSPECTIONS.
- Open
EL1886 — Violation
PROVIDE PERMIT TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRE, DEVICES, EQUIPMENT AT THE 1ST FLOOR, 2ND FLOOR, AND BASEMENT. 2ND FLOOR CONVERTED INTO A PARTY ROOM. MISCELLANEOUS MODIFICATIONS 1ST FLOOR AND BASEMENT, SERVICE MOTIFIED (14A-4-404.6) INSUFFICIENT PERMITS, NO PERMITS, NO INSPECTIONS.
- Open
EL1836 — PANEL SCHEDULES
INSUFFICIENT PANEL SCHEDULES
- Open
EL1819 — DEFECTIVE FIXTURES
CORRODED LIGHT FIXTURES AT REAR EXTERIOR, REPLACE FIXTURES WHERE REQUIRED
- Open
EL1875 — INSTALL GFCI'S
INSTALL GFCI PROTECTION AT SINKS, BATHS, KITCHEN, BASEMENT, WET LOCATIONS AT EXTERIOR
- Open
EL1885 — Violation
EXTERIOR LIGHT FIXTURES, BOXES, FITTINGS, RACEWAYS MUST BE SUITABLE FOR WET LOCATIONS 14E-1-110.3
- Open
EL1824 — INSTALL ILLUMINATION
INSTALL OPERABLE ILLUMINATION AT ALL EXTERIOR ENTRIES
- Open
EL1880 — DETERIORATED CONDUCTORS
DETERIORATED, DAMAGED WIRING VISIBLE AT OPEN BOXES. REPLACE WHERE REQUIRED.
- Open
EL1806 — PROPER SIZE GRD ELECTRODE COND
NO VISIBLE WATER GROUND DANGEROUS AND HAZARDOUS
- Open
EL1809 — WORKING SPACE
2ND FLOOR ELECTRICAL PANEL IS BURIED BEHIND DOOR DANGEROUS AND HAZARDOUS
- Open
NC2011 — PLANS & PERMITS REQ - CONTRCTR
THE 2CD FLOOR ABOVE THE LICENSED BAR HAS AN EVENT SPACE THAT IS NOT LICENSED. PLANS AND PERMITS ARE REQUIRED TO OBTAIN A PPA LICENSE FOR THE 2CD FLOOR SPACE. THE REAR PATIO WAS INSTALLED WITHOUT PLANS OR PERMITS. THIS PATIO SPACE HAS AN EXPIRED LICENSE.SECTION 14A-4-404.
- Open
EL0029 — EXPOSED WIRING
FROM THE BASEMENT TO THE 1ST FLOOR THERE EXISTS NUMEROUS LOCATIONS OF EXPOSED, LIVE, ELECTRICAL WIRING. EXTREMELY DANGEROUS AND HAZARDOUS.SECTION 14X-7-701.
- Open
CN106015 — REPAIR INTERIOR STAIR SYSTEM
BEHIND THE BAR IS A SET OF STAIRS TO THE BASEMENT. THEREE IS NO BANNISTER AT THE TOP AND NO HAND RAILS ON THE STAIRS. THERE IS A HAZARD OF THE BAR TENDERS STEPPING BACK AND FALLING INTO THE BASEMENT. DANGEROUS AND HAZARDOUS.SECTION 14X-3-304.
- Open
CN069014 — REPAIR DEFECTIVE FOUNDATION
THE MASONARY BASEMENT FOUNDATION IS DEGRADED WITH MUCH MOISTURE PENETRATION CAUSING SEVERE EFFLORESSENCE. SECTION 14X-3-303.
- Open
EL0019 — DEFECTIVE FIXTURES
THE BASEMENT AND 1ST FLOOR BAR HAVE NUMEROUS DEFECTIVE LIGHT FIXTURES. DANGEROUS AND HAZARDOUS.SECTION 14X-7-701.
- Open
CN061064 — BUILDING IN DISREPAIR
THE BAR AND THE 2CD FLOOR EVENT SPACE HAVE BEEN ISSUED DOB / BACP CLOSURES. THERE ARE DANGEROUS AND HAZARDOUS EGRESS ITEMS AS WELL AS EXTREMELY DANGEROUS AND HAZARDOUS ELECTRICAL VIOLATIONS; SO MUCH SO THAT A COMED DISCONNECT ORDER HAS BEEN ISSUED. THERE ARE ALSO NUMEROUS PLUMBING VIOLATIONS PENDING THAT ARE NOT IN THIS REPORT.SECTION 14XA-3-315.
- Heat-related
CN011012 — HEATING PLANT/BOILER ROOM DOOR
THE BASEMENT BOILER ENCLOSURE HAS A PLYWOOD DOOR. INSTALL A CLASS B FIRE DOOR. SECTION 14B-7-716.
- Open
CN039013 — POST APPROVED OCCUPANCY CARD
THE BAR AND THE PATIO HAVE NO OCCUPANCY PLACARDS. IF THE 2CD FLOOR EVENT SPACE BECOMES LICENSED AND APPROVED FOR USE, A PLACARD IS REQUIRED IN THAT SPACE AS WELL.
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
THERE IS A LARGE HOLE IN THE 2CD FLOOR CEILING.
- Open
CN190019 — ARRANGE PREMISE INSPECTION
NO ACCESS TO INTERIOR FOR 2018 ANNUAL INSPECTION.
- Open
CN017012 — INTERIOR FINISH FIRERESISTANCE
PROVIDE FLAMESPREAD RATING ON ALL PANELING THRU-OUT
- Open
CN101015 — REPAIR INTERIOR WALLS/CEILING
REAR ROOM CEILING FRACTURES AND MISSING PLASTER (BREACHES AT VARIOUS LOCATIONS) PROVIDE 1 HOUR FIRE RATED CEILING)
- Open
NC5012 — CLASS B DOOR IN STAIRWELL
INSTALL A FIRE RATED B DOOR WITH FRAME AND SELF CLOSER AND 2ND FLOOR STAIRWELL.
- Open
EL0023 — INSTALL COVERS
REAR OF BUILDING
- Open
EL0033 — SECURE RACEWAY
SIDE OF BUILDING
- Open
NC2021 — PERMIT REQUIRED - CONTRACTOR
REPLACE 2ND FLOOR WINDOWS WITHOUT LANDMARK PERMIT OR APPROVAL
- Open
199029 — OPEN TYPE VIOLATION
STOP ALL WORK UNTIL PERMIT IS OBTAINED SEC (13-12-080) AND (13-32-035)
About these City violation records
From the City of Chicago Building Violations dataset description: “…informational only and does not necessarily reflect the current condition of the building or property. The dataset contains cases where a respondent has been found to be liable as well as cases where the respondent has been found to be not liable.”
311 complaints (24 months)
No matching 311 complaints in the last 24 months.
Timeline
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
- Open City violation record — EL1809 WORKING SPACE
- Open City violation record — EL1806 PROPER SIZE GRD ELECTRODE COND
- Open City violation record — EL1880 DETERIORATED CONDUCTORS
- Open City violation record — EL1824 INSTALL ILLUMINATION
- Open City violation record — EL1885
- Open City violation record — EL1875 INSTALL GFCI'S
- Open City violation record — EL1819 DEFECTIVE FIXTURES
- Open City violation record — EL1836 PANEL SCHEDULES
- Open City violation record — EL1886
- Open City violation record — EL1886
- Open City violation record — PL194029 PROVIDE
- Open City violation record — PL163027 PROVIDE OPEN FRONT TOILET SEAT
- Open City violation record — PL234002 SOIL/WASTE,VENT PIPE MATRL
- Open City violation record — PL237004 INDIRECT CONN.FOR WATER SUPPLY
- Open City violation record — PL232011 OBTAIN PERMIT FOR PLUMBING
- Open City violation record — PL239010 ENGAG LIC & BOND PLMBNG CNTRC
- Open City violation record — CN070024 REPAIR PORCH SYSTEM
- Open City violation record — NC2071 WORK NOT ALLOWED
- Open heat-related City violation record — CN010012 1-HR HEATING PLANT ENCLOSURE
- Open heat-related City violation record — CN011012 HEATING PLANT/BOILER ROOM DOOR
- Open City violation record — CN012022 1HR FLR OVER BSMT, 1 OR 2 DU
- Open City violation record — EL1884 SEE INSPECTOR COMMENTS
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN116025 LOAD BEARING ARCH. REPORT
- Open City violation record — CN103035 STRUCTURAL MEMBER, PIER BLOCK
- Open City violation record — EL1801 DEFECTIVE SERVICE
- Open City violation record — EL1805 DEFECTIVE DISTRIBUTION
- Open City violation record — CN101015 REPAIR INTERIOR WALLS/CEILING
- Open City violation record — CN039013 POST APPROVED OCCUPANCY CARD
- Open heat-related City violation record — CN011012 HEATING PLANT/BOILER ROOM DOOR
- Open City violation record — CN061064 BUILDING IN DISREPAIR
- Open City violation record — EL0019 DEFECTIVE FIXTURES
- Open City violation record — CN069014 REPAIR DEFECTIVE FOUNDATION
- Open City violation record — CN106015 REPAIR INTERIOR STAIR SYSTEM
- Open City violation record — EL0029 EXPOSED WIRING
- Open City violation record — NC2011 PLANS & PERMITS REQ - CONTRCTR
- Open City violation record — CN190019 ARRANGE PREMISE INSPECTION
Recently closed / other violations (sample)
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
EL0020 SUPPORT FIXTURES
- Closed / other
CN015062 OBSTRUCTIONS IN EXIT WAY
- Closed / other
NC3042 UNINTERRUPTED EXIT AT GRADE
- Closed / other
CN107035 MAINTAIN EXIT SIGN ILLUMINATED
- Closed / other
EL0016 ADD RECEPTACLES
- Closed / other
EL0018 DEFECTIVE OUTLETS
- Closed / other
CN140016 DWELLING CLEAN AND SANITARY
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
CN190019 ARRANGE PREMISE INSPECTION
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
CN015022 DOOR SWING IN DIR. OF TRAVEL
- Closed / other
CN015022 DOOR SWING IN DIR. OF TRAVEL
- Closed / other
NC5012 CLASS B DOOR IN STAIRWELL
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
CN199029
- Closed / other
199029 OPEN TYPE VIOLATION
- Closed / other
199029 OPEN TYPE VIOLATION
Around 1935 W Thomas St
- West Town community area: search another address
- No heat in your Chicago apartment? The heat ordinance and what to do
Nearby buildings with open City violation records
Nearby addresses that also have open City violation records in the City of Chicago Building Violations dataset (22u3-xenr), by distance. Open each one for its current free report.
How the winter score is calculated
- Start at 100 (better = higher).
- Minus up to 40 for open heat/boiler-related building violations (12 pts each).
- Minus up to 45 for other open building violations (2 pts each, plus extras above 20 and 100 open).
- Minus up to 20 for rodent-related open violations and 311 rodent complaints (4 pts each).
- Minus up to 15 for recent 311 building complaints (2 pts each).
- Extra −10 if 3+ open heat-related violations.
- Chicago 311 takes no-heat complaints, but the City's public 311 dataset does not publish them as a separate type, so heat here comes from open Department of Buildings heat-related violations (codes/descriptions, e.g. CN132016 HEAT UNIT ADEQUATELY). 311 building complaints are counted separately, not as heat.
- Public records only — not an inspection, appraisal, or legal advice.
Sources: City of Chicago Building Violations (data.cityofchicago.org/d/22u3-xenr); City of Chicago 311 Service Requests (data.cityofchicago.org/d/v6vf-nfxy). Data: City of Chicago (chicago.gov). Data as of November 22, 2026 at 1:46 AM CT.
ScoutMyBuilding summarizes publicly available City data. It is informational only — not legal advice, not a housing inspection, and not a guarantee of current building conditions. City records may be incomplete, delayed, or inaccurate. Always verify with the City of Chicago Department of Buildings, 311, and your own walkthrough before signing a lease.
“This site provides applications using data that has been modified for use from its original source, www.cityofchicago.org, the official website of the City of Chicago. The City of Chicago makes no claims as to the content, accuracy, timeliness, or completeness of any of the data provided at this site. The data provided at this site is subject to change at any time. It is understood that the data provided at this site is being used at one’s own risk.” Required by the City of Chicago Data Terms of Use.